Versatile XPS system for ultra-thin film analysis
Brochures and specifications | 2013 | Thermo Fisher ScientificInstrumentation
Ultra-thin film characterization is essential across microelectronics, advanced coatings, surface engineering and nanomaterials. Precise, non-destructive analysis of layer composition, thickness and chemical state underpins quality control, reliability testing and fundamental research. Angle-resolved X-ray photoelectron spectroscopy (ARXPS) has emerged as a leading tool for probing material interfaces and buried layers at the nanometer scale.
This document presents the design principles, core capabilities and application scope of the Thermo Scientific Theta Probe surface analysis system. It aims to illustrate how parallel ARXPS, combined with micro-focused monochromatic X-rays, advanced sample handling and integrated software, simplifies ultra-thin film measurements and expands analytical performance.
The Theta Probe integrates several complementary techniques to deliver high-precision surface analysis:
Parallel ARXPS streamlines depth-sensitive analysis by capturing entire angular distributions simultaneously, accelerating measurement times and improving throughput. Constant energy resolution across angles yields reliable thickness and composition profiles. Micro-focused SAXPS enables mapping of chemical heterogeneity in self-assembled monolayers, graphene films and high-k dielectric stacks. The MAGCIS cluster ion mode minimizes damage during depth profiling of polymers and soft materials. Together, these features deliver high sensitivity, spatial resolution and reproducibility for complex thin film systems.
Key advantages of the Theta Probe system include:
Advances in ultra-thin film analysis will be driven by deeper integration of ARXPS with in situ processing chambers, machine learning–based peak deconvolution and 3D nanoscale chemical imaging. Emerging needs in quantum materials, flexible electronics and biomaterials will push development of gentler ion sources, cryogenic stages and higher-energy X-ray optics.
The Theta Probe surface analysis system combines parallel ARXPS, micro-focused monochromatic X-rays, advanced sample navigation and comprehensive software to deliver a robust platform for ultra-thin film characterization. Its modular design and high sensitivity address the growing demands of research and industrial laboratories for precise, efficient and non-invasive surface analysis.
No external references were provided in the source document.
X-ray
IndustriesMaterials Testing
ManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
Ultra-thin film characterization is essential across microelectronics, advanced coatings, surface engineering and nanomaterials. Precise, non-destructive analysis of layer composition, thickness and chemical state underpins quality control, reliability testing and fundamental research. Angle-resolved X-ray photoelectron spectroscopy (ARXPS) has emerged as a leading tool for probing material interfaces and buried layers at the nanometer scale.
Objectives and Study Overview
This document presents the design principles, core capabilities and application scope of the Thermo Scientific Theta Probe surface analysis system. It aims to illustrate how parallel ARXPS, combined with micro-focused monochromatic X-rays, advanced sample handling and integrated software, simplifies ultra-thin film measurements and expands analytical performance.
Methodology and Instrumentation
The Theta Probe integrates several complementary techniques to deliver high-precision surface analysis:
- Parallel ARXPS (PARXPS) enabling angle-resolved measurements without mechanical tilting and with constant analysis area and energy resolution.
- Micro-focused monochromated Al Kα X-ray source (spot sizes from 15 to 400 μm) for small-feature sensitivity and chemical state imaging.
- Dual-mode ion sources (standard ion gun and optional MAGCIS gas cluster/monatomic ion gun) for gentle cleaning and depth profiling.
- Integrated Avantage software for data acquisition, background subtraction, peak fitting, quantification, principal component analysis and multi-dimensional visualization.
- Automated 5-axis sample stage (up to 90 × 90 × 25 mm) with optical alignment cameras and unattended multi-sample operation.
Main Results and Discussion
Parallel ARXPS streamlines depth-sensitive analysis by capturing entire angular distributions simultaneously, accelerating measurement times and improving throughput. Constant energy resolution across angles yields reliable thickness and composition profiles. Micro-focused SAXPS enables mapping of chemical heterogeneity in self-assembled monolayers, graphene films and high-k dielectric stacks. The MAGCIS cluster ion mode minimizes damage during depth profiling of polymers and soft materials. Together, these features deliver high sensitivity, spatial resolution and reproducibility for complex thin film systems.
Benefits and Practical Applications
Key advantages of the Theta Probe system include:
- Non-destructive depth profiling of multi-layer stacks in semiconductors, coatings and organic electronics.
- Quantitative chemical state imaging for failure analysis, contamination control and interface studies.
- Automated sample handling and software routines for high throughput in QA/QC laboratories.
- Flexible configuration options—UV photoelectron spectroscopy, Auger, SEM integration—for multi-modal surface characterization.
Future Trends and Potential Applications
Advances in ultra-thin film analysis will be driven by deeper integration of ARXPS with in situ processing chambers, machine learning–based peak deconvolution and 3D nanoscale chemical imaging. Emerging needs in quantum materials, flexible electronics and biomaterials will push development of gentler ion sources, cryogenic stages and higher-energy X-ray optics.
Conclusion
The Theta Probe surface analysis system combines parallel ARXPS, micro-focused monochromatic X-rays, advanced sample navigation and comprehensive software to deliver a robust platform for ultra-thin film characterization. Its modular design and high sensitivity address the growing demands of research and industrial laboratories for precise, efficient and non-invasive surface analysis.
Reference
No external references were provided in the source document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Theta Probe: Small Spot XPS Spectrometer with Parallel ARXPS Capability
2008|Thermo Fisher Scientific|Brochures and specifications
Application Note: 31055 Theta Probe: Small Spot XPS Spectrometer with Parallel ARXPS Capability Description Key Words • Parallel ARXPS • Surface Analysis • Ultra-thin Films The Thermo Scientific Theta Probe, Figure 1, is a highperformance XPS instrument. Our patented Theta…
Key words
theta, thetathickness, thicknessprobe, probexps, xpsparxps, parxpsgun, gunsample, sampleangle, anglemaps, mapsray, raydepth, depthavantage, avantageturbomolecular, turbomolecularoverlayer, overlayermulti
Thermo Scientific™ Nexsa™ G2 Surface Analysis System
2021|Thermo Fisher Scientific|Brochures and specifications
Nexsa G2 Surface Analysis System Fast travel to definitive surface analysis Definitive surface analysis Why the Nexsa G2 System XPS SnapMap Multi-technique Avantage Data System Definitive surface analysis Surface and interface analysis can be challenging. It requires instrumentation that can…
Key words
avantage, avantagesnapmap, snapmapxps, xpsdefinitive, definitivesurface, surfacesystem, systemray, raydata, dataspectroscopy, spectroscopyanalysis, analysismulti, multisource, sourcetechnique, techniquereels, reelscorrelative
Nexsa Surface Analysis System Brochure
2018|Thermo Fisher Scientific|Brochures and specifications
Nexsa Surface Analysis System High-performance XPS with multi-technique integration Confident analysis Surface and interface analysis can be challenging. It requires instrumentation that can deliver results with confidence to inform the next steps. The Thermo Scientific™ Nexsa™ Surface Analysis System is…
Key words
xps, xpsnexsa, nexsasnapmap, snapmapmagcis, magcisavantage, avantagesource, sourceray, raysurface, surfaceraman, ramandual, dualmodule, modulereels, reelsarxps, arxpsflood, floodspectroscopy
Nexsa G2 Surface Analysis System
2022|Thermo Fisher Scientific|Brochures and specifications
Datasheet Nexsa G2 Surface Analysis System Fast travel to definitive surface analysis As a materials researcher, you need a surface analysis system that quickly and efficiently provides high-quality, accurate data collection so you can understand the composition of surfaces, thin…
Key words
xps, xpsalignment, alignmentholder, holdersource, sourcesystem, systemsample, samplemounting, mountingbacking, backingsoftware, softwareixr, ixrholders, holdersmaps, mapsdata, dataavantage, avantagespot