7700 Series ICP-MS – Site Preparation Checklist
Manuals | 2015 | Agilent TechnologiesInstrumentation
Proper site preparation for the Agilent 7700 Series ICP-MS is essential to ensure reliable performance, extend instrument lifetime, maintain safety, and guarantee data quality in trace elemental analysis. Meticulous planning of space, utilities, and environmental conditions minimizes installation delays, protects investment, and supports regulatory compliance in research, quality control, and industrial laboratories.
This document summarizes the key requirements and recommendations for laboratory readiness prior to the delivery and installation of the Agilent 7700 Series ICP-MS system. It covers customer responsibilities, dimensional constraints, environmental controls, power and utility provisions, gas supplies, cooling water, network needs, and other practical considerations.
Used Instrumentation:
Space and Weight:
Adherence to these site preparation guidelines ensures rapid and trouble-free installation of the ICP-MS system, reduces instrument downtime, enhances data reproducibility, and safeguards operator safety. Optimized exhaust and cooling prevent contamination and thermal stress, while proper electrical and gas infrastructure supports versatile analytical workflows from environmental monitoring to pharmaceutical QC.
Advances in lab automation and remote diagnostics will further streamline instrument commissioning and maintenance. Integration with IoT-enabled environmental sensors could provide real-time site condition monitoring. Emerging gas-saving and green cooling technologies will reduce operational costs and environmental impact.
Thorough planning and execution of site preparation steps—covering space, utilities, environment, and safety—are fundamental to achieving the full analytical potential of the Agilent 7700 Series ICP-MS. Early coordination with facility managers and Agilent service teams fosters a smooth installation, reliable operation, and long-term performance.
ICP/MS
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
Proper site preparation for the Agilent 7700 Series ICP-MS is essential to ensure reliable performance, extend instrument lifetime, maintain safety, and guarantee data quality in trace elemental analysis. Meticulous planning of space, utilities, and environmental conditions minimizes installation delays, protects investment, and supports regulatory compliance in research, quality control, and industrial laboratories.
Objectives and Overview
This document summarizes the key requirements and recommendations for laboratory readiness prior to the delivery and installation of the Agilent 7700 Series ICP-MS system. It covers customer responsibilities, dimensional constraints, environmental controls, power and utility provisions, gas supplies, cooling water, network needs, and other practical considerations.
Methodology and Instrumentation
Used Instrumentation:
- Agilent 7700 Series ICP-MS mainframe (models G3281A, G3282A, G5700A)
- Data system computer and monitor
- Foreline vacuum pump
- Agilent Chiller (G3292A or G3159A) or Heat Exchanger (G1879B)
- Autosamplers (SPS 4 G8415A, Integrated I-AS, or ASX-500 series)
- Regulators and stainless steel tubing for high-purity Ar, He, H₂ or optional NH₃/He cell gas
Key Requirements and Discussion
Space and Weight:
- Dedicated bench area to accommodate the mainframe (approx. 73×62×59.5 cm) and largest shipping container (100×100×85 cm), plus 60 cm clearance on all sides for maintenance.
- Bench load capacity to support up to 157 kg per shipping container and 115 kg for the mainframe.
- Ambient temperature 15–30 °C with stability of <2 °C/hr (<5 °C total change).
- Relative humidity 20–80% non-condensing.
- Maximum altitude 2000 m.
- Continuous exhaust flow of 5.0–7.0 m³/min through 150 mm ID ducting, with ±5% flow stability, vented externally.
- Dedicated circuit: 200–240 VAC, 50/60 Hz, 24 A for ICP-MS; additional outlets for computer, chiller, heat exchanger, and autosamplers.
- Isolated, noise-free ground; no extension cords.
- Chiller or heat exchanger with Poly-Clear fluid or recirculator using distilled water (conductivity 50–150 µS).
- Flow rate ≥5 L/min at 15–40 °C inlet temperature; inlet pressure 230–400 kPa.
- High-purity Ar (≥99.99%, CGA 580) at 500–700 kPa for plasma with consumption ~20 L/min.
- Optional He cell gas (≥99.999%) and H₂ gas (≥99.999%) at 90–130 kPa for collision/reaction cell modes.
- Use dedicated cylinders, stainless steel tubing (<3 m), and approved regulators with stainless steel diaphragms.
- Microsoft Account for software activation.
- Optional LAN connection via a 10/100 Mbps switch with two static IP addresses; no dual-NIC configurations.
Benefits and Practical Applications
Adherence to these site preparation guidelines ensures rapid and trouble-free installation of the ICP-MS system, reduces instrument downtime, enhances data reproducibility, and safeguards operator safety. Optimized exhaust and cooling prevent contamination and thermal stress, while proper electrical and gas infrastructure supports versatile analytical workflows from environmental monitoring to pharmaceutical QC.
Future Trends and Opportunities
Advances in lab automation and remote diagnostics will further streamline instrument commissioning and maintenance. Integration with IoT-enabled environmental sensors could provide real-time site condition monitoring. Emerging gas-saving and green cooling technologies will reduce operational costs and environmental impact.
Conclusion
Thorough planning and execution of site preparation steps—covering space, utilities, environment, and safety—are fundamental to achieving the full analytical potential of the Agilent 7700 Series ICP-MS. Early coordination with facility managers and Agilent service teams fosters a smooth installation, reliable operation, and long-term performance.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
7700 Series ICP-MS – Site Preparation Checklist
2013|Agilent Technologies|Manuals
7700 Series ICP-MS – Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is the…
Key words
checklist, checklistsite, sitespecial, specialnotes, notestechnologies, technologiescompressed, compressedagilent, agilentpreparation, preparationgas, gaswatts, wattsconsumption, consumptionrequirements, requirementsdescription, descriptionkpa, kpaoperating
Agilent 8800 Triple Quadrupole ICP-MS – Site Preparation Checklist
2015|Agilent Technologies|Manuals
Agilent 8800 Triple Quadrupole ICP-MS – Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation…
Key words
checklist, checklistsite, sitespecial, specialnotes, notestechnologies, technologiescompressed, compressedagilent, agilentgas, gaspreparation, preparationwatts, wattsconsumption, consumptionrequirements, requirementsheat, heatdescription, descriptionkpa
1 700 Series ICP-OES Site Preparation Checklist
2012|Agilent Technologies|Manuals
700 Series ICP-OES Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is the key…
Key words
checklist, checklistsite, sitespecial, specialnotes, notestechnologies, technologieswatts, wattsagilent, agilentpreparation, preparationoperating, operatingcustomer, customerconsumption, consumptioncompressed, compressedheat, heatinstrument, instrumentweight
Agilent 5100 Series ICP-OES Site Preparation Checklist
2014|Agilent Technologies|Manuals
Agilent 5100 Series ICP-OES Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is the…
Key words
checklist, checklistsite, sitespecial, specialnotes, notestechnologies, technologiesagilent, agilentwatts, wattspreparation, preparationoperating, operatingcustomer, customerdescription, descriptionmaximum, maximumconsumption, consumptioncompressed, compressedheat