Author
Eurachem
Eurachem
Eurachem is a European network promoting international traceability of chemical measurements and good analytical practice. It provides expert guidance, supports method validation, uncertainty evaluation, proficiency testing, and facilitates discussion on technical and policy issues in analytical quality.
Tags
Article
Academy
LinkedIn Logo

How to investigate poor performance in proficiency testing

Tu, 2.6.2026
| Original article from: Eurachem
Learn how laboratories should investigate poor proficiency testing results, identify root causes, implement corrective actions, and improve quality management to prevent recurring issues.
<p>Eurachem: How to investigate poor performance in proficiency testing</p>

Eurachem: How to investigate poor performance in proficiency testing

A laboratory will occasionally have a poor performance in a PT scheme. When this occurs, the laboratory should acknowledge it, carry out an investigation and document a review of possible causes, even if it decides not to take any specific action. The purpose of this leaflet is to advise laboratories on how to best address such events. A good management of the poor performance in a PT can save you time and money. 

Evaluation of poor performance 

Every unsatisfactory performance score indicates a problem which needs to be investigated. In addition the laboratory should set its own criteria for launching an investigation with regards to other indicators of possible poor performance, such as questionable performance scores or observed trends.

Root cause investigation 

The depth of the investigation will depend on several factors, such as the importance of the analysis, the frequency of unsatisfactory results and evidence of trends. 

The laboratory should check whether the PT report gives an explanation for the unsatisfactory performance. If no reason is provided, a stepwise approach is preferable to maximize the chances of determining the root cause of the problem. This approach is described in Annex B of the Eurachem Guide [1].

Eurachem: How to investigate poor performance in proficiency testing - Annex BEurachem: How to investigate poor performance in proficiency testing - Annex B

The investigation should consist of the following steps and involve the personnel that performed the analysis and where approporiate, also involve the laboratory management: 

  1. Analyse the raw data, internal quality control data, any trend from previous PT rounds and the overall performance of the participants in that round; 
  2. After investigation is complete, make a plan for corrective action and consider implications for previous test results; 
  3. Execute and record the corrective action(s); 
  4. Check whether the corrective action(s) was effective. 

Causes for poor performance 

The causes of poor performance can be grouped into three categories: 

  1. Clerical errors are not directly linked to the laboratory’s technical competence, but can underline that the laboratory may have a potential problem when reporting results to its customers. Clerical errors can include transcription errors, mislabelling, incorrect units and decimal point errors. Identifying them is an important first step of an investigation. If such errors are a regular cause of poor performance, the investigation should focus on the related aspects of the quality management system. 
  2. Technical problems can occur at any step of the analytical procedure. If the investigation does not enable the laboratory to identify the root cause, it may be necessary to review the method validation. 
  3. Problems related to the PT scheme. Poor performance could also be due to the PT scheme not being entirely appropriate. The Eurachem Guide [1] provides information on selecting an appropriate PT scheme. In other cases, a problem may have occurred with the PT items. The laboratory is encouraged to discuss its findings with the PT provider. 

The “Fishbone diagram” or “5 Whys” are useful tools to investigate the root cause of a problem.

Case studies 

Example 1

A medical laboratory has provided results in a PT scheme for tumor markers in serum with a 20 % deviation from the assigned value, although the daily internal controls performed well. The laboratory investigates the process and discovers the mistake was due to an incorrect unit conversion factor being introduced for PT results when the IT system was last updated. Since patient results are reported in a different unit than the one used by the PT provider no patient results were affected. 

Eurachem: How to investigate poor performance in proficiency testingEurachem: How to investigate poor performance in proficiency testing

Example 2

A laboratory performing food and feed analyses obtained poor performance scores on Listeria monocytogenes enumeration, because the number of microorganisms found was underestimated. Laboratory investigations showed an issue in incubation time and temperature applied by the analyst. The laboratory found that the analyst used an out-of-date procedure.

Eurachem: How to investigate poor performance in proficiency testingEurachem: How to investigate poor performance in proficiency testing

Resources

[1] B. Brookman and I. Mann (eds.) Eurachem Guide: Selection, Use and Interpretation of Proficiency Testing (PT) Schemes (3rd ed. 2021). Available from www.eurachem.org.

Eurachem
LinkedIn Logo
 

Related content

Agilent 9500 ICP‑QQQ with m‑Lens for Ultratrace Analysis of High‑Purity Reagents

Applications
| 2026 | Agilent Technologies
Instrumentation
ICP/MS, ICP/MS/MS
Manufacturer
Agilent Technologies
Industries
Semiconductor Analysis

Analysis of copper alloys with the ARL X900 XRF Spectrometer

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
X-ray
Manufacturer
Thermo Fisher Scientific
Industries
Materials Testing

Measurement of Fixed Carbon, Volatile Matter, and Ash of Biocoke

Applications
| 2026 | Shimadzu
Instrumentation
Thermal Analysis
Manufacturer
Shimadzu
Industries
Energy & Chemicals

Detection of Phenol Leakage into Wastewater Using TOC Measurement

Applications
| 2026 | Shimadzu
Instrumentation
TOC
Manufacturer
Shimadzu
Industries
Environmental

Routine Analysis of Rare Earth Elements in Basalt using ICP-MS

Applications
| 2026 | Agilent Technologies
Instrumentation
ICP/MS
Manufacturer
Agilent Technologies
Industries
Materials Testing
 

Related articles

Basic instructions for participants in a proficiency testing scheme
Article | Academy

Basic instructions for participants in a proficiency testing scheme

A practical checklist for laboratories participating in proficiency testing (PT) schemes. Learn the key steps—from receiving PT samples to reviewing reports and implementing corrective actions.
Eurachem
tag
share
more
How can proficiency testing help my laboratory?
Article | Academy

How can proficiency testing help my laboratory?

Learn how proficiency testing (PT) supports quality assurance in analytical laboratories, from z-score evaluation to bias assessment and long-term performance monitoring.
Eurachem
tag
share
more
Selecting the right proficiency testing scheme for my laboratory
Article | Academy

Selecting the right proficiency testing scheme for my laboratory

How to select the right proficiency testing (PT) scheme for your laboratory? Key criteria, practical examples, and guidance for ensuring reliable and compliant results.
Eurachem
tag
share
more
Proficiency testing schemes for sampling
Article | Academy

Proficiency testing schemes for sampling

Learn how ISO/IEC 17043 applies to proficiency testing schemes for sampling, including evaluation models, statistical design, homogeneity, assigned values, and sampling uncertainty.
Eurachem
tag
share
more
 

Related content

Agilent 9500 ICP‑QQQ with m‑Lens for Ultratrace Analysis of High‑Purity Reagents

Applications
| 2026 | Agilent Technologies
Instrumentation
ICP/MS, ICP/MS/MS
Manufacturer
Agilent Technologies
Industries
Semiconductor Analysis

Analysis of copper alloys with the ARL X900 XRF Spectrometer

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
X-ray
Manufacturer
Thermo Fisher Scientific
Industries
Materials Testing

Measurement of Fixed Carbon, Volatile Matter, and Ash of Biocoke

Applications
| 2026 | Shimadzu
Instrumentation
Thermal Analysis
Manufacturer
Shimadzu
Industries
Energy & Chemicals

Detection of Phenol Leakage into Wastewater Using TOC Measurement

Applications
| 2026 | Shimadzu
Instrumentation
TOC
Manufacturer
Shimadzu
Industries
Environmental

Routine Analysis of Rare Earth Elements in Basalt using ICP-MS

Applications
| 2026 | Agilent Technologies
Instrumentation
ICP/MS
Manufacturer
Agilent Technologies
Industries
Materials Testing
 

Related articles

Basic instructions for participants in a proficiency testing scheme
Article | Academy

Basic instructions for participants in a proficiency testing scheme

A practical checklist for laboratories participating in proficiency testing (PT) schemes. Learn the key steps—from receiving PT samples to reviewing reports and implementing corrective actions.
Eurachem
tag
share
more
How can proficiency testing help my laboratory?
Article | Academy

How can proficiency testing help my laboratory?

Learn how proficiency testing (PT) supports quality assurance in analytical laboratories, from z-score evaluation to bias assessment and long-term performance monitoring.
Eurachem
tag
share
more
Selecting the right proficiency testing scheme for my laboratory
Article | Academy

Selecting the right proficiency testing scheme for my laboratory

How to select the right proficiency testing (PT) scheme for your laboratory? Key criteria, practical examples, and guidance for ensuring reliable and compliant results.
Eurachem
tag
share
more
Proficiency testing schemes for sampling
Article | Academy

Proficiency testing schemes for sampling

Learn how ISO/IEC 17043 applies to proficiency testing schemes for sampling, including evaluation models, statistical design, homogeneity, assigned values, and sampling uncertainty.
Eurachem
tag
share
more
 

Related content

Agilent 9500 ICP‑QQQ with m‑Lens for Ultratrace Analysis of High‑Purity Reagents

Applications
| 2026 | Agilent Technologies
Instrumentation
ICP/MS, ICP/MS/MS
Manufacturer
Agilent Technologies
Industries
Semiconductor Analysis

Analysis of copper alloys with the ARL X900 XRF Spectrometer

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
X-ray
Manufacturer
Thermo Fisher Scientific
Industries
Materials Testing

Measurement of Fixed Carbon, Volatile Matter, and Ash of Biocoke

Applications
| 2026 | Shimadzu
Instrumentation
Thermal Analysis
Manufacturer
Shimadzu
Industries
Energy & Chemicals

Detection of Phenol Leakage into Wastewater Using TOC Measurement

Applications
| 2026 | Shimadzu
Instrumentation
TOC
Manufacturer
Shimadzu
Industries
Environmental

Routine Analysis of Rare Earth Elements in Basalt using ICP-MS

Applications
| 2026 | Agilent Technologies
Instrumentation
ICP/MS
Manufacturer
Agilent Technologies
Industries
Materials Testing
 

Related articles

Basic instructions for participants in a proficiency testing scheme
Article | Academy

Basic instructions for participants in a proficiency testing scheme

A practical checklist for laboratories participating in proficiency testing (PT) schemes. Learn the key steps—from receiving PT samples to reviewing reports and implementing corrective actions.
Eurachem
tag
share
more
How can proficiency testing help my laboratory?
Article | Academy

How can proficiency testing help my laboratory?

Learn how proficiency testing (PT) supports quality assurance in analytical laboratories, from z-score evaluation to bias assessment and long-term performance monitoring.
Eurachem
tag
share
more
Selecting the right proficiency testing scheme for my laboratory
Article | Academy

Selecting the right proficiency testing scheme for my laboratory

How to select the right proficiency testing (PT) scheme for your laboratory? Key criteria, practical examples, and guidance for ensuring reliable and compliant results.
Eurachem
tag
share
more
Proficiency testing schemes for sampling
Article | Academy

Proficiency testing schemes for sampling

Learn how ISO/IEC 17043 applies to proficiency testing schemes for sampling, including evaluation models, statistical design, homogeneity, assigned values, and sampling uncertainty.
Eurachem
tag
share
more
 

Related content

Agilent 9500 ICP‑QQQ with m‑Lens for Ultratrace Analysis of High‑Purity Reagents

Applications
| 2026 | Agilent Technologies
Instrumentation
ICP/MS, ICP/MS/MS
Manufacturer
Agilent Technologies
Industries
Semiconductor Analysis

Analysis of copper alloys with the ARL X900 XRF Spectrometer

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
X-ray
Manufacturer
Thermo Fisher Scientific
Industries
Materials Testing

Measurement of Fixed Carbon, Volatile Matter, and Ash of Biocoke

Applications
| 2026 | Shimadzu
Instrumentation
Thermal Analysis
Manufacturer
Shimadzu
Industries
Energy & Chemicals

Detection of Phenol Leakage into Wastewater Using TOC Measurement

Applications
| 2026 | Shimadzu
Instrumentation
TOC
Manufacturer
Shimadzu
Industries
Environmental

Routine Analysis of Rare Earth Elements in Basalt using ICP-MS

Applications
| 2026 | Agilent Technologies
Instrumentation
ICP/MS
Manufacturer
Agilent Technologies
Industries
Materials Testing
 

Related articles

Basic instructions for participants in a proficiency testing scheme
Article | Academy

Basic instructions for participants in a proficiency testing scheme

A practical checklist for laboratories participating in proficiency testing (PT) schemes. Learn the key steps—from receiving PT samples to reviewing reports and implementing corrective actions.
Eurachem
tag
share
more
How can proficiency testing help my laboratory?
Article | Academy

How can proficiency testing help my laboratory?

Learn how proficiency testing (PT) supports quality assurance in analytical laboratories, from z-score evaluation to bias assessment and long-term performance monitoring.
Eurachem
tag
share
more
Selecting the right proficiency testing scheme for my laboratory
Article | Academy

Selecting the right proficiency testing scheme for my laboratory

How to select the right proficiency testing (PT) scheme for your laboratory? Key criteria, practical examples, and guidance for ensuring reliable and compliant results.
Eurachem
tag
share
more
Proficiency testing schemes for sampling
Article | Academy

Proficiency testing schemes for sampling

Learn how ISO/IEC 17043 applies to proficiency testing schemes for sampling, including evaluation models, statistical design, homogeneity, assigned values, and sampling uncertainty.
Eurachem
tag
share
more
Other projects
GCMS
LCMS
Follow us
FacebookLinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike