Neoma Multicollector ICP-MS

Brochures and specifications | 2020 | Thermo Fisher ScientificInstrumentation
ICP/MS
Industries
Other
Manufacturer
Thermo Fisher Scientific

Summary

Importance of the Topic


Accurate isotope ratio analysis underpins research in geochemistry, environmental science, nuclear safeguarding and materials characterization. High‐precision multicollector ICP‐MS platforms resolve subtle variations in isotopic abundances, enabling age dating, provenance studies and process tracing. Modern laboratories require systems that combine exceptional sensitivity, precision, operational flexibility and streamlined workflows for both routine and cutting‐edge applications.

Objectives and Article Overview


This article presents the Thermo Scientific Neoma MC-ICP-MS, a next-generation multicollector instrument designed to push the boundaries of sensitivity, precision and ease-of-use. Key design innovations, integrated software capabilities, performance benchmarks and future upgrade paths are reviewed to illustrate how this platform transforms isotope ratio measurements.

Methodology and Instrumentation


  • iCAP Qnova Series ICP with digital 27 MHz RF generator, balanced coil plasma stability and single‐piece demountable quartz torch for robust, high‐transmission ion generation.
  • Jet Interface coupled with a desolvating nebulizer yields 10–20× sensitivity gains over wet plasma, routinely delivering >1.5% ion yields for uranium and lead.
  • Magnetic sector analyzer featuring an 11-cup movable Faraday array, a central dual‐mode detector (Faraday/SEM) and 24 amplifier slots for customizable collector configurations.
  • Thermo Scientific 10¹³ Ω Amplifier Technology housed in a temperature‐controlled, doubly shielded module, extending dynamic range to 6 Gcps while achieving counting‐statistic limited precision at low ion currents.
  • Optional Retarding Potential Quadrupole (RPQ) lenses for enhanced abundance sensitivity and eXtra High Resolution (XHR) apertures (resolving power up to 15 000) to separate hydride interferences.
  • Qtegra ISDS software provides unified control of the MC-ICP-MS and peripherals (laser ablation, chromatography, desolvators), automated tuning, real‐time transient signal analysis and report generation.

Key Results and Discussion


  • The Neoma MC-ICP-MS achieves market‐leading sensitivity (tens of Gcps/ppm) across elements from Li to U, with dry plasma enhancing signal by more than an order of magnitude.
  • Static isotope ratio precision approaches theoretical counting‐statistics limits even at low signal levels (30 kcps–3 Mcps) thanks to ultra‐low noise 10¹³ Ω amplifiers and high‐stability Faraday detection.
  • RPQ application reduces ²³²Th tailing onto m/z 229.5 by an order of magnitude, enabling accurate measurement of low‐abundance isotopes such as ²³⁴U/²³⁸U and ²³⁶U/²³⁸U.
  • XHR mode resolves polyatomic interferences (e.g., ⁴⁰Ar¹H from ⁴¹K), unlocking precise δ⁴¹K measurements and broadening accessible isotope systems.
  • Multi-ion counting (MIC) arrays support simultaneous detection of ultra-low abundance beams (U/Pb, U/Th, Re/Os), streamlining geochronology and tracer studies in single analyses.

Benefits and Practical Applications


  • Rapid switching between low, medium, high and extra high resolution modes and flexible collector layouts accommodate diverse isotopic targets without hardware changes.
  • Automated one-click tuning, integrated peripheral control and intuitive workflows reduce operator training and maximize daily sample throughput.
  • Enhanced dynamic range and low-noise performance enable trace-level isotope analyses for geochronology, environmental monitoring, nuclear forensics and materials research.
  • Modular upgrade options—including future MS/MS collision/reaction cell capability—ensure long-term adaptability to emerging analytical challenges.

Future Trends and Potential Applications


Ongoing developments in collision/reaction cell MS/MS will expand interference removal and in-situ geochronology workflows (e.g., Rb/Sr dating). Enhanced resolution and sensitivity support emerging fields such as biomedical isotope tracing, agricultural nutrient cycling and extraterrestrial sample analysis. Integration with automated sample introduction and advanced data analytics will further increase throughput and data reliability.

Conclusion


The Thermo Scientific Neoma MC-ICP-MS represents a significant advance in multicollector ICP-MS technology by combining ultra-high sensitivity, precision and dynamic range with flexible detection, optional high‐resolution and collision cell upgrades, and streamlined software automation. Its versatile architecture addresses both routine QA/QC requirements and frontier research applications, empowering scientists to push the edge of discovery.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Neoma™ MS/MS Multicollector ICP-MS
Neoma™ MS/MS Multicollector ICP-MS
2022|Thermo Fisher Scientific|Brochures and specifications
Mass Spectrometry Break through the noise Neoma™ MS/MS Multicollector ICP-MS Break through the noise Complex science doesn’t mean complicated analyses. The Thermo Scientific™ Neoma™ MS/MS MC-ICP-MS filters out the noise to give you world-class isotope ratio data with stunning clarity.…
Key words
neoma, neomaicp, icpsrf, srfcell, cellrpq, rpqmass, massmulticollector, multicollectoricap, icaptechnology, technologyreaction, reactionsensitivity, sensitivityisobaric, isobaricisotope, isotopefilter, filtercollision
High precision in situ Rb-Sr age dating
High precision in situ Rb-Sr age dating
2023|Thermo Fisher Scientific|Applications
Application note | 002246 Mass spectrometry High precision in situ Rb-Sr age dating Authors Goal A. Cruz-Uribe To demonstrate how the Thermo Scientific™ Neoma™ MS/MS MC-ICP-MS can be used for University of Maine, in situ Rb-Sr age dating. Orono, Maine,…
Key words
srf, srfneoma, neomaicp, icpablation, ablationbasalt, basaltmass, masswien, wienmulticollector, multicollectorglasses, glassesntin, ntinfilter, filterdownhole, downholecounting, countingglass, glassgranite
Do we have a choice of reaction gas for measuring Ca? Investigations using the Thermo Scientific Neoma MS/MS MC-ICP-MS
Multicollector ICP-MS Do we have a choice of reaction gas for measuring Ca? Investigations using the Thermo Scientific Neoma MS/MS MC-ICP-MS S. Dalby, S. Milano, G. Craig, M. Pfeifer, C. Bouman, N. Lloyd; Thermo Fisher Scientific, Bremen, Germany Abstract High…
Key words
cct, cctneoma, neomaicp, icpmulticollector, multicollectorisotopic, isotopicreaction, reactionsitu, situamplifi, amplificode, codescan, scannuclides, nuclidescaf, caffield, fieldprefilter, prefiltercollision
High precision hafnium isotope ratio measurements
High precision hafnium isotope ratio measurements
2021|Thermo Fisher Scientific|Applications
APPLICATION BRIEF 000097 High precision hafnium isotope ratio measurements Authors: G. Craig, M. Pfeifer, C. Bouman, N. Lloyd, J. Schwieters; Thermo Fisher Scientific, Bremen, Germany Keywords: Neoma, MC-ICP-MS, Hf, isotope ratio, Geosciences Introduction The Thermo Scientific™ Neoma™ MC-ICP-MS is the…
Key words
rse, rseppm, ppmneoma, neomaisotope, isotopeicp, icpapproximately, approximatelyprevious, previousmean, meanhafnium, hafniumamplifier, amplifierprecision, precisioncps, cpscup, cuptwice, twicewet