Agilent ICP-MS IntelliQuant Analysis
Technical notes | 2024 | Agilent TechnologiesInstrumentation
Inductively coupled plasma mass spectrometry (ICP-MS) is a cornerstone technique in analytical chemistry for trace element analysis. IntelliQuant enhances ICP-MS by providing automated semiquantitative screening, interference assessment, and data confidence metrics. This capability accelerates sample evaluation, supports robust quality control, and uncovers unexpected matrix effects, making routine workflows more efficient and data‐rich.
The technical overview describes the development and implementation of Agilent’s ICP-MS IntelliQuant technology. Key aims include:
QuickScan captures the complete mass range under helium kinetic energy discrimination (KED) mode. IntelliQuant uses this scan to:
IntelliQuant Star Rating translates these multivariate metrics into a five‐star confidence scale. An interference simulator allows virtual testing of interference scenarios without sample preparation or plasma operation.
Validation with NIST 1643f water standard showed accurate recoveries (98–110%) for certified elements in the unspiked sample, all achieving five‐star ratings. Spiking with rare earth elements (Nd, Sm) at 0.1, 1, and 10 ppm revealed increasing interference on As and Se. IntelliQuant detected these interferences, downgrading star ratings from five to one as interference severity rose. Heat map and star rating visualizations highlighted matrix effects and allowed rapid identification of compromised results.
Advances may include expansion of interference databases for emerging matrices, integration of machine learning for predictive data quality management, real‐time method optimization based on sample matrix, and broader adoption across diverse ICP-MS platforms. Enhanced user interfaces and cloud‐based data analytics could further streamline lab workflows and support remote diagnostics.
Agilent’s IntelliQuant and Star Rating deliver a powerful, user‐friendly approach to semiquantitative ICP-MS analysis. By automating data calibration, matrix assessment, and quality evaluation, the technology enhances throughput, confidence, and insight into complex sample matrices. It represents a significant step forward in making comprehensive elemental screening accessible to a broad range of laboratories.
Software, ICP/MS
IndustriesOther
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Inductively coupled plasma mass spectrometry (ICP-MS) is a cornerstone technique in analytical chemistry for trace element analysis. IntelliQuant enhances ICP-MS by providing automated semiquantitative screening, interference assessment, and data confidence metrics. This capability accelerates sample evaluation, supports robust quality control, and uncovers unexpected matrix effects, making routine workflows more efficient and data‐rich.
Objectives and Study Overview
The technical overview describes the development and implementation of Agilent’s ICP-MS IntelliQuant technology. Key aims include:
- Introducing QuickScan to acquire full mass spectra in two seconds per sample.
- Generating semiquantitative element profiles in a periodic table heat map.
- Calculating Total Matrix Solids (TMS) to assess matrix load.
- Applying a multivariate Star Rating system to evaluate data confidence.
Methodology and Instrumentation
QuickScan captures the complete mass range under helium kinetic energy discrimination (KED) mode. IntelliQuant uses this scan to:
- Determine semiquantitative concentrations for every measurable element.
- Compute TMS by summing key matrix elements and excluding volatile gas elements.
- Identify spectral interferences via a comprehensive interference database covering different plasma conditions and collision modes.
- Assess data quality factors: spectral interferences, measurement precision, detection limits, backgrounds, and calibration integrity.
IntelliQuant Star Rating translates these multivariate metrics into a five‐star confidence scale. An interference simulator allows virtual testing of interference scenarios without sample preparation or plasma operation.
Used Instrumentation
- Agilent 7700, 7800, 7850, 7900 ICP-MS
- Agilent 8800, 8900 ICP-QQQ
- ICP-MS MassHunter software versions 4.6 and 5.3
Main Results and Discussion
Validation with NIST 1643f water standard showed accurate recoveries (98–110%) for certified elements in the unspiked sample, all achieving five‐star ratings. Spiking with rare earth elements (Nd, Sm) at 0.1, 1, and 10 ppm revealed increasing interference on As and Se. IntelliQuant detected these interferences, downgrading star ratings from five to one as interference severity rose. Heat map and star rating visualizations highlighted matrix effects and allowed rapid identification of compromised results.
Benefits and Practical Applications
- Automated semiquantitative screening enables full element profiling without method changes.
- Real-time interference alerts improve data reliability and reduce reanalysis.
- Periodic table heat map and star ratings simplify data interpretation for QA/QC and R&D teams.
- Interference simulator supports method development and training without consuming consumables.
Future Trends and Opportunities
Advances may include expansion of interference databases for emerging matrices, integration of machine learning for predictive data quality management, real‐time method optimization based on sample matrix, and broader adoption across diverse ICP-MS platforms. Enhanced user interfaces and cloud‐based data analytics could further streamline lab workflows and support remote diagnostics.
Conclusion
Agilent’s IntelliQuant and Star Rating deliver a powerful, user‐friendly approach to semiquantitative ICP-MS analysis. By automating data calibration, matrix assessment, and quality evaluation, the technology enhances throughput, confidence, and insight into complex sample matrices. It represents a significant step forward in making comprehensive elemental screening accessible to a broad range of laboratories.
Reference
- Agilent publication 5994-1171EN (IntelliQuant and KED mode details).
- Agilent publication 5994-7441EN (MassHunter software overview).
- NIST Standard Reference Material 1643f – Trace Elements in Water.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent IntelliQuant for ICP-MS
2020|Agilent Technologies|Technical notes
Technical Overview Agilent IntelliQuant for ICP-MS Fast, automated semiquantitative ICP-MS analysis provides greater sample insight and confidence in the results Smart tools simplify ICP-MS operation and data review Analytical laboratories, particularly in the commercial sector, are under constant pressure to…
Key words
intelliquant, intelliquantsemiquantitative, semiquantitativeicp, icpelements, elementstms, tmssolids, solidsmap, mapdata, datadoubly, doublyincluded, includedprovides, providescharged, chargedquantitative, quantitativedisplay, displayheat
Determination of Heavy Metals in Cannabis and Hemp Products Following AOAC Method for ICP-MS
2021|Agilent Technologies|Applications
Application Note Cannabis & Hemp Testing Determination of Heavy Metals in Cannabis and Hemp Products Following AOAC Method for ICP-MS Routine monitoring of As, Cd, Hg, Pb, and other elements using an Agilent 7850 ICP-MS Authors Jenny Nelson, Craig Jones,…
Key words
cbd, cbdhemp, hempaoac, aoaccannabis, cannabisuhmi, uhmidigestion, digestionsrms, srmsmethod, methodtopical, topicalrecovery, recoveryicp, icpsample, sampleelement, elementconc, concdilution
Accurate Analysis of Factory Effluents using ICP-MS with Aerosol Dilution
2024|Agilent Technologies|Applications
Application Note Environmental Accurate Analysis of Factory Effluents using ICP-MS with Aerosol Dilution Agilent 7850 ICP-MS with UHMI provides the sensitivity, dynamic range, and robustness for analysis of high matrix samples Authors Shinichi Tobe, Hisanaga Takeshita, and Yoshinori Kato NAITOH…
Key words
hehe, hehegas, gasrecovery, recoveryelements, elementsmatrix, matrixmeasured, measuredicp, icpcertified, certifiedcrms, crmsspiked, spikedelement, elementwastewater, wastewatermode, modeuhmi, uhmihigh
Determination of Critical Elements in Foods in Accordance with US FDA EAM 4.7 ICP-MS Method
2021|Agilent Technologies|Applications
Application Note Foods Determination of Critical Elements in Foods in Accordance with US FDA EAM 4.7 ICP-MS Method Extending the scope of routine food analysis using IntelliQuant data analysis Introduction Authors Jenny Nelson Elaine Hasty2 Leanne Anderson2 Macy Harris2 1…
Key words
pass, passintelliquant, intelliquantgummy, gummybears, bearsjerky, jerkyfortified, fortifiedelements, elementseam, eamdonuts, donutschocolate, chocolaterecovery, recoverytms, tmsconc, concfood, foodicp