Single Quadrupole ICP-MS vs Triple Quadrupole ICP-MS

Guides | 2022 | Agilent TechnologiesInstrumentation
ICP/MS, ICP/MS/MS
Industries
Manufacturer
Agilent Technologies

Summary

Importance of the Topic


ICP-MS is a pivotal technique in analytical chemistry for rapid, multi-element determination with ppt-level detection limits. The development of single quadrupole and triple quadrupole (ICP-QQQ) configurations addresses a range of industrial, environmental, and research applications that require high sensitivity and robust interference control.

Objectives and Overview


This whitepaper contrasts single quadrupole ICP-MS with triple quadrupole ICP-MS (ICP-QQQ), illustrating their operating principles, relative performance, and application suitability. It guides users in selecting the optimal instrumentation for routine trace analysis, complex matrices, and emerging contaminants.

Methodology and Instrumentation


Instrumentation
  • Single quadrupole ICP-MS: one mass filter, collision/reaction cell, electron multiplier detector.
  • Triple quadrupole ICP-MS (ICP-QQQ): dual quadrupole filters (Q1 pre-cell, Q2 post-cell) enabling controlled MS/MS operation and reactive gas chemistries.

Key components
  1. Sample Introduction: pneumatic nebulizer and spray chamber produce fine aerosol; injector ID affects dwell time and ionization efficiency.
  2. ICP Torch: inductively coupled argon plasma (~10 000 °C) for sample atomization and ionization.
  3. Interface: sampling and skimmer cones transfer ions from atmospheric pressure to high vacuum.
  4. Ion Optics and Collision/Reaction Cell: octopole lenses steer ions; He collision mode for kinetic energy discrimination; reactive gases (H₂, O₂, NH₃) in ICP-QQQ resolve specific interferences.
  5. Mass Analysis and Detection: fast‐scanning quadrupole filters and discrete dynode electron multiplier for single‐ion counting and wide dynamic range.


Main Results and Discussion


Performance Comparison
  • Sensitivity and Limits: ICP-QQQ delivers up to tenfold lower detection limits and reduced background via tandem mass filtering and reactive chemistry control.
  • Interference Handling: single quadrupole with He KED mitigates common polyatomic overlaps; ICP-QQQ removes direct isobaric, doubly charged, and peak-tail interferences through MS/MS filtering.
  • Matrix Compatibility: ultra‐high matrix introduction (UHMI) permits direct analysis of high-salt and high-acid digests without extensive dilution.

Application Highlights
  1. Environmental Water Screening: rapid multielement analysis (≤1 min per sample) across ppt–ppm ranges.
  2. Speciation Analysis: coupling with IC or HPLC to differentiate toxic and benign species (e.g., Cr(III)/Cr(VI), As species, organomercury).
  3. Single Particle and Single Cell ICP-MS: nanoparticle counting and sizing down to <30 nm; quantification of metal content in individual cells.
  4. High‐Purity Chemical Testing: sub-ppt impurity detection in semiconductor-grade acids and solvents; fluorine determination via BaF⁺ reactive ion monitoring.


Practical Benefits and Applications


The quadrupole ICP-MS portfolio addresses routine QA/QC, environmental compliance, food and pharmaceutical safety, geochemical surveys, and materials characterization. ICP-QQQ expands these capabilities to ultra-trace analyses, challenging matrices, and emerging contaminants such as nanoparticles and microplastics.

Future Trends and Opportunities


  • Advanced Speciation Workflows: deeper integration with chromatographic and electrophoretic separations for molecular-level insights.
  • Enhanced Imaging Techniques: laser ablation and automated stage control for 2D/3D elemental mapping in biological and geological samples.
  • New Reaction Gas Chemistries: tailored cell gases and AI-driven optimization to further suppress interferences and streamline method development.
  • Hyphenated and Ambient Ionization Methods: combination with novel ion sources to broaden the analytical scope in life sciences and clinical research.


Conclusion


Single quadrupole ICP-MS remains the versatile workhorse for general multielement analysis with balanced cost, ease of use, and sensitivity. ICP-QQQ offers unmatched interference removal and detection capability for the most demanding trace- and ultratrace-level applications. Instrument selection should align with sample complexity, required detection limits, and interference challenges.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent 8900 Triple Quadrupole ICP-MS (Technical Overview)
Agilent 8900 Triple Quadrupole ICP-MS (Technical Overview)
2025|Agilent Technologies|Technical notes
Agilent 8900 Triple Quadrupole ICP-MS Technical Overview Introduction Agilent is the worldwide market leader in quadrupole ICP-MS, and the only supplier of triple quadrupole ICP-MS (ICP-QQQ). Introduced in 2012, ICP‑QQQ has transformed interference removal in ICP‑MS, using MS/MS to control…
Key words
icp, icpqqq, qqqsensitivity, sensitivityacceleration, accelerationions, ionscell, celldls, dlsreaction, reactionquadrupole, quadrupoleapplications, applicationssemiconductor, semiconductorsignal, signalaxial, axialnps, npshigh
Handbook of ICP-QQQ Applications using the Agilent 8800 and 8900
5th Edition Handbook of ICP-QQQ Applications using the Agilent 8800 and 8900 Primer > Return to table of contents > Search entire document Foreword Agilent Technologies launched its 8800 Triple Quadrupole ICP-MS (ICP-QQQ) at the 2012 Winter Conference on Plasma…
Key words
return, returncontents, contentstable, tableicp, icpqqq, qqqcps, cpsgas, gasmass, massppt, pptcell, celldocument, documentconc, concentire, entiresearch, searchmode
Atomic Spectroscopy Applications in the Environmental Laboratory
April 2020 Edition Atomic Spectroscopy Applications in the Environmental Laboratory Applications compendium > Search entire document Table of contents Title Page Agilent atomic spectroscopy solutions for the analysis of drinking water, wastewater, soils, and sludges 3 Atomic spectroscopy techniques 5…
Key words
icp, icpatomic, atomicreturn, returndocument, documententire, entiresearch, searchcontents, contentstable, tableqqq, qqqelements, elementsspectroscopy, spectroscopyplasma, plasmaaes, aesoes, oesemission
ICP-QQQ Applications in Geochemistry, Mineral Analysis, and Nuclear Science
Applications of ICP-MS ICP-QQQ Applications in Geochemistry, Mineral Analysis, and Nuclear Science Application Compendium > Return to table of contents > Search entire document Explore New Opportunities in Geochemistry, Mineral Analysis, and Nuclear Science With the Agilent 8900 ICP-QQQ Agilent…
Key words
return, returncontents, contentstable, tableicp, icpree, reeqqq, qqqmass, masscps, cpscell, cellgas, gasybo, yboshift, shiftwwtp, wwtprare, rareelement
Other projects
GCMS
LCMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike