The Latest Advances in Axially Viewed Simultaneous ICP-OES for Elemental Analysis
Technical notes | 2010 | Agilent TechnologiesInstrumentation
Inductively coupled plasma optical emission spectrometry (ICP-OES) remains a cornerstone technique for multi-elemental analysis, combining rapid throughput with low detection limits. Axially viewed ICP-OES enhances sensitivity by observing the long analyte‐rich central channel of the plasma, addressing environmental, industrial and quality control demands where trace detection and wide dynamic range are critical.
This application note reviews the latest developments in axially viewed simultaneous ICP-OES, focusing on improvements in detector design, plasma interface, software algorithms and sample introduction. The goal is to illustrate how modern systems overcome historical limitations—such as restricted dynamic range and matrix interferences—while increasing productivity and method robustness.
The advances presented are based on the Agilent Vista series of simultaneous ICP-OES instruments, featuring:
Detector and interface upgrades deliver significant performance gains:
Axially viewed simultaneous ICP-OES with CCI and advanced CCD detectors offers:
Ongoing developments may include:
Modern axially viewed simultaneous ICP-OES systems combine cooled cone interfaces, megapixel CCD detectors and intelligent software to deliver exceptional sensitivity, wide dynamic range and matrix tolerance in a single analytical configuration. These innovations streamline workflows, reduce consumable usage and expand the applicability of ICP-OES to demanding environmental, industrial and research applications.
ICP-OES
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
Inductively coupled plasma optical emission spectrometry (ICP-OES) remains a cornerstone technique for multi-elemental analysis, combining rapid throughput with low detection limits. Axially viewed ICP-OES enhances sensitivity by observing the long analyte‐rich central channel of the plasma, addressing environmental, industrial and quality control demands where trace detection and wide dynamic range are critical.
Objectives and Study Overview
This application note reviews the latest developments in axially viewed simultaneous ICP-OES, focusing on improvements in detector design, plasma interface, software algorithms and sample introduction. The goal is to illustrate how modern systems overcome historical limitations—such as restricted dynamic range and matrix interferences—while increasing productivity and method robustness.
Methodology and Instrumentation Used
The advances presented are based on the Agilent Vista series of simultaneous ICP-OES instruments, featuring:
- An echelle polychromator coupled to a high-pixel CCD detector (Vista-Pro and Vista-MPX) providing over 96% wavelength coverage from 167–782 nm.
- The VistaChip image-mapping approach, aligning >70 000 detector elements to the echellogram, and the megapixel Vista-MPX array with >1.1 million pixels for full spectral capture.
- A cooled cone interface (CCI) that displaces the cooler plasma fringe from the optical path via a water-cooled nickel cone and argon counter-flow, reducing atomization interferences and extending linearity.
- Modular sample introduction components—double-pass spray chambers, v-groove nebulizers, wide-bore injector tubes and demountable axial torches—to support up to 25 % dissolved solids without blockages.
Main Results and Discussion
Detector and interface upgrades deliver significant performance gains:
- Sensitivity: Axial viewing yields 4–10× lower detection limits than radial configurations, achieving sub-ppb levels for many elements.
- High-solids stability: Continuous aspiration of 5 % NaCl over 3.5 hours gave relative standard deviations <2.5 % without rinsing; 25 % NaCl was analyzed for 24 hours with 3–5 % precision.
- Linear dynamic range (LDR): Using the CCI, single-view axial measurements provide accurate results up to 500–600 mg/L for major elements, matching radial view performance.
- MultiCal software: Automated wavelength selection and combination extends LDR by blending signals from multiple lines into a single quantitative result, assuring optimal accuracy across concentration ranges.
Benefits and Practical Applications of the Method
Axially viewed simultaneous ICP-OES with CCI and advanced CCD detectors offers:
- Enhanced trace detection and broad dynamic range in a single run, eliminating the need for dual-view analyses.
- Improved throughput and reduced argon consumption (2.5 L/min vs. 15–20 L/min for shear gas systems).
- Robust analysis of challenging matrices including high-salt, organic solvents and industrial slurries.
- Stable, drift-free performance without moving optics or background correction lamps.
Future Trends and Potential Applications
Ongoing developments may include:
- Further expansion of detector pixel density and readout speed for real-time process monitoring.
- Enhanced software intelligence leveraging machine learning for interference correction and predictive maintenance.
- Integration with separation techniques (e.g., HPLC-ICP-OES) for speciated analysis in pharmaceuticals and food safety.
- Miniaturized, field-deployable axial ICP-OES units for environmental surveillance and on-site quality control.
Conclusion
Modern axially viewed simultaneous ICP-OES systems combine cooled cone interfaces, megapixel CCD detectors and intelligent software to deliver exceptional sensitivity, wide dynamic range and matrix tolerance in a single analytical configuration. These innovations streamline workflows, reduce consumable usage and expand the applicability of ICP-OES to demanding environmental, industrial and research applications.
References
- M.H. Abdallah et al., Anal. Chim. Acta 84 (1976) 271–282.
- C. Dubuisson, E. Poussel, J.-M. Mermet, J. Anal. At. Spectrom. 12 (1997) 281–286.
- J.M. Harnly, R.E. Fields, Appl. Spectrosc. 51 (1997) 334A–351A.
- T.W. Barnard et al., Anal. Chem. 65 (1993) 1231–1239.
- A.T. Zander et al., Anal. Chem. 71 (1999) 3332–3340.
- US EPA ILM05.0 Inorganics Multi-media Multi-concentration SOW.
- J.-P. Lener, V. Lecourbe, Varian Report (2000).
- I.B. Brenner, A.T. Zander, Spectrochim. Acta B 55 (2000) 195–240.
- F. Minnelli, Varian Report (2001).
- T.T. Nham, EWCPS Paper 0-18 (2001).
- I. Szikla, Varian At Work 30 (2001).
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Dedicated axial or radial plasma view for superior speed and performance
2012|Agilent Technologies|Technical notes
Dedicated axial or radial plasma view for superior speed and performance Technical overview Introduction The superior design of the Agilent 700 Series ICP-OES instruments, which feature either an axially or radially-viewed plasma, results in better speed and performance than instruments…
Key words
plasma, plasmaview, viewradial, radialoes, oesviewing, viewingaxial, axialtail, tailicp, icpinterferences, interferencessystems, systemsemission, emissionionization, ionizationdual, dualzone, zoneoptical
AGILENT 710 SERIES ICP-OES
2010|Agilent Technologies|Brochures and specifications
Accurate. Robust. Reliable. AGILENT 710 SERIES ICP-OES Agilent 710 Series ICP-OES Agilent Technologies is now your premier resource and partner for atomic spectroscopy. With the 2010 addition of Varian’s world-renowned AA and ICP-OES products, together with our market-leading 7700 Series…
Key words
crql, crqlicp, icpoes, oesplasma, plasmaworld, worldwavelength, wavelengthagilent, agilentwavelengths, wavelengthsrange, rangeccd, ccdvarian, variandynamic, dynamicfastest, fastestrecombination, recombinationmultical
Agilent 720/725 ICP-OES
2012|Agilent Technologies|Brochures and specifications
Agilent 720/725 ICP-OES RELIABLE. PRODUCTIVE. ROBUST. AGILENT TECHNOLOGIES 720/725 ICP-OES The world’s best ICP-OES The Agilent 720/725 ICP-OES systems are the world’s most productive highperformance and only truly simultaneous ICP-OES. The Agilent 720/725 ICP-OES offer the finest performance, nce, speed…
Key words
multical, multicalagilent, agilenticp, icpwavelength, wavelengthmetals, metalsvistachip, vistachipelements, elementsremarkably, remarkablyfact, facttechnologies, technologiescorrection, correctionsoftware, softwarecoverage, coverageexpert, expertproductive
Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES
2010|Agilent Technologies|Applications
Fast Analysis of Water Samples Comparing Axially-and RadiallyViewed CCD Simultaneous ICP-OES Application Note Inductively Coupled Plasma-Optical Emission Spectrometers Author Introduction Tran T. Nham With the benefits of typically 5–10 fold improvement in detection limits of the axially viewed ICP compared…
Key words
inductively, inductivelyaxially, axiallyvista, vistaplasma, plasmaicp, icpmeasured, measuredcontract, contractviewed, viewedterm, termpolychromator, polychromatoraxial, axialinorganics, inorganicsradially, radiallyechelle, echellecoupled