Analysis of Bovine Liver using the Agilent 5100 Synchronous Vertical Dual View (SVDV) ICP-OES
Applications | 2014 | Agilent TechnologiesInstrumentation
Analysis of elemental composition in animal food products is critical for ensuring compliance with international regulations and safeguarding public health and the environment. Methods capable of simultaneous detection of nutrients and toxic elements with high sensitivity and throughput are essential for food testing laboratories.
This study evaluates the performance of the Agilent 5100 Synchronous Vertical Dual View ICP OES for multi element analysis of a bovine liver standard reference material. Key aims include assessment of linear dynamic range, accuracy against certified values and method detection limits.
Sample Preparation and Standards
The system achieved a linear dynamic range for sodium and potassium up to 500 ppm with correlation coefficients above 0.999 and calibration errors below ten percent. Measured concentrations for major and trace elements matched certified values within five percent. Method detection limits spanned low mg per kg levels. Spike recoveries for trace elements demonstrated accuracy between ninety nine and one hundred ten percent.
The approach enables simultaneous measurement of elements present at widely varying concentrations in a single run, reducing analysis time and argon consumption. The vertical torch design enhances robustness against complex matrices and extends maintenance intervals. Simplified software workflows and plug and play hardware support high sample throughput and reproducible results across operators and instruments.
Integration of this technology with automated sample handling and data analysis platforms will further increase laboratory efficiency. Advances in detector technology and software algorithms may expand the linear dynamic range and lower detection limits. Potential applications include environmental monitoring, clinical research and industrial quality control.
The Agilent 5100 Synchronous Vertical Dual View ICP OES with Dichroic Spectral Combiner offers a versatile and reliable solution for multi element analysis in food matrices. It combines high sensitivity, broad dynamic range and operational simplicity to meet the demands of modern analytical laboratories.
ICP-OES
IndustriesFood & Agriculture
ManufacturerAgilent Technologies
Summary
Importance of the topic
Analysis of elemental composition in animal food products is critical for ensuring compliance with international regulations and safeguarding public health and the environment. Methods capable of simultaneous detection of nutrients and toxic elements with high sensitivity and throughput are essential for food testing laboratories.
Objectives and Study Overview
This study evaluates the performance of the Agilent 5100 Synchronous Vertical Dual View ICP OES for multi element analysis of a bovine liver standard reference material. Key aims include assessment of linear dynamic range, accuracy against certified values and method detection limits.
Methodology and Instrumentation
Sample Preparation and Standards
- Bovine liver SRM 1577A was digested by microwave in nitric acid and hydrogen peroxide and diluted to a fixed volume.
- Calibration standards ranged from low ppb to high ppm in acid medium and a 100 ppb spike was applied to evaluate trace recovery.
- The instrument uses a vertical plasma torch and Dichroic Spectral Combiner to merge axial and radial views in one measurement.
- Sample introduction employed a SeaSpray nebulizer, cyclonic spray chamber and demountable torch.
- A solid state radio frequency generator ensured stable plasma operation.
- Operating conditions included defined read times, replicate scans, gas flows and pump rates optimized for robust performance.
Main Results and Discussion
The system achieved a linear dynamic range for sodium and potassium up to 500 ppm with correlation coefficients above 0.999 and calibration errors below ten percent. Measured concentrations for major and trace elements matched certified values within five percent. Method detection limits spanned low mg per kg levels. Spike recoveries for trace elements demonstrated accuracy between ninety nine and one hundred ten percent.
Benefits and Practical Applications
The approach enables simultaneous measurement of elements present at widely varying concentrations in a single run, reducing analysis time and argon consumption. The vertical torch design enhances robustness against complex matrices and extends maintenance intervals. Simplified software workflows and plug and play hardware support high sample throughput and reproducible results across operators and instruments.
Future Trends and Opportunities
Integration of this technology with automated sample handling and data analysis platforms will further increase laboratory efficiency. Advances in detector technology and software algorithms may expand the linear dynamic range and lower detection limits. Potential applications include environmental monitoring, clinical research and industrial quality control.
Conclusion
The Agilent 5100 Synchronous Vertical Dual View ICP OES with Dichroic Spectral Combiner offers a versatile and reliable solution for multi element analysis in food matrices. It combines high sensitivity, broad dynamic range and operational simplicity to meet the demands of modern analytical laboratories.
Reference
- Drvodelic N Analysis of Bovine Liver using the Agilent 5100 Synchronous Vertical Dual View ICP OES Agilent Technologies Publication 5991 4868EN July 2014
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Synchronous Vertical Dual View (SVDV) for superior speed and performance
2014|Agilent Technologies|Technical notes
Synchronous Vertical Dual View (SVDV) for superior speed and performance Technical Overview 5100 ICP-OES What is Synchronous Vertical Dual View (SVDV)? The Agilent 5100 ICP-OES revolutionizes ICP-OES analysis. It is designed to run your samples faster, using less gas, without…
Key words
radial, radialaxial, axialelements, elementsemissions, emissionsdsc, dsceie, eieoes, oesread, readwavelengths, wavelengthsicp, icpvertical, verticallight, lightplasma, plasmaview, viewsynchronously
Determination of Elemental Nutrients and Micronutrients in Functional Foods by ICP-OES
2022|Agilent Technologies|Applications
Application Note Foods Determination of Elemental Nutrients and Micronutrients in Functional Foods by ICP-OES Accurate EAM 4.4 compliant results using the Agilent 5900 SVDV ICP-OES with smart tools Authors Introduction Ruby Bradford Functional foods are foods that supplement the diet…
Key words
pass, passfitted, fittedelements, elementsnone, nonefoods, foodssvdv, svdveffervescent, effervescentbackground, backgroundelement, elementwavelength, wavelengthfbc, fbcfunctional, functionalfortified, fortifiedview, viewintelliquant
Rapid Multi-Elemental Analysis of Fertilizers using the Agilent 5110 VDV ICP-OES
2019|Agilent Technologies|Applications
Application Note Soil quality and fertilizer analysis Rapid Multi-Elemental Analysis of Fertilizers using the Agilent 5110 VDV ICP-OES Accurate determination of 21 elements in under one minute Author Daniel Oppedisano Agilent Technologies, Melbourne, Australia Introduction Successful, high-yield crop production often…
Key words
axial, axialfitted, fittedradial, radialfertilizer, fertilizerelements, elementsvista, vistaelement, elementviewing, viewingssrf, ssrftorch, torchbackground, backgroundsample, samplecorrection, correctionchip, chipconcentration
Synchronous Vertical Dual View (SVDV) for superior speed and performance
2016|Agilent Technologies|Technical notes
Synchronous Vertical Dual View (SVDV) for superior speed and performance Technical Overview 5110 ICP-OES What is Synchronous Vertical Dual View (SVDV)? The Agilent 5110 ICP-OES revolutionizes ICP-OES analysis. It is designed to run your samples faster, using less gas, without…
Key words
radial, radialaxial, axialelements, elementsemissions, emissionsdsc, dsceie, eieoes, oesread, readwavelengths, wavelengthsicp, icpvertical, verticallight, lightplasma, plasmaview, viewsynchronously