AGILENT 4100 MICROWAVE PLASMA – ATOMIC EMISSION SPECTROMETER
Brochures and specifications | 2011 | Agilent TechnologiesInstrumentation
The Agilent 4100 MP-AES represents a major advance in atomic emission spectroscopy by eliminating the need for flammable and costly gases. Running on air, it delivers sub-ppb detection limits, faster multi-element analysis than flame atomic absorption (AA), and enhanced laboratory safety and sustainability.
This article introduces the Agilent 4100 MP-AES system and its goal to create a new class of gas-free, microwave-plasma atomic emission spectrometers. It outlines performance targets such as reduced operating cost, improved sensitivity, unattended operation, and applicability across industries including mining, food safety, environmental monitoring, and petrochemicals.
The core excitation source is a magnetically excited microwave plasma generated by an industrial magnetron. Emission is collected by a wide-range, low-noise CCD detector, enabling simultaneous measurement of analyte signals and background. Plug-and-play hardware features a torch loader for fast alignment and software-controlled air injection for organic matrices. The main components include:
The 4100 MP-AES achieves detection limits below parts-per-billion, outperforming flame AA in sensitivity and dynamic range. Cost-of-ownership analyses show gas-savings recoup initial investment within five months, with over USD 40,000 saved after 18 months for routine nine-element assays. Stability tests demonstrate <2% RSD over eight hours in organic solvents. Certified reference material analyses (tea leaves, rice flour, bovine liver) confirm accuracy for major and trace elements. Geological, agricultural, food and petrochemical matrices are processed without dilution, highlighting the system’s robustness.
Key advantages include:
Advances in field-deployable spectroscopy, integration with automated sample-prep platforms, and enhanced data connectivity to laboratory information management systems (LIMS) will further broaden MP-AES applications. Emerging opportunities include on-site geochemical analysis, real-time environmental monitoring, and coupling with machine-learning algorithms for predictive quality control. Continuous optimization of hydride generation and organic-matrix handling will expand the detectable element suite and lower detection thresholds.
The Agilent 4100 MP-AES establishes a new standard in atomic spectroscopy by combining high sensitivity, safety, and ultra-low operating costs. Its innovative magnetically excited microwave plasma source, gas-free design, and user-friendly software make it a versatile solution for laboratories seeking reliable, unattended multi-element analysis.
No external literature references were provided in the original material.
GD/MP/ICP-AES
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
The Agilent 4100 MP-AES represents a major advance in atomic emission spectroscopy by eliminating the need for flammable and costly gases. Running on air, it delivers sub-ppb detection limits, faster multi-element analysis than flame atomic absorption (AA), and enhanced laboratory safety and sustainability.
Objectives and Study Overview
This article introduces the Agilent 4100 MP-AES system and its goal to create a new class of gas-free, microwave-plasma atomic emission spectrometers. It outlines performance targets such as reduced operating cost, improved sensitivity, unattended operation, and applicability across industries including mining, food safety, environmental monitoring, and petrochemicals.
Methodology and Instrumentation
The core excitation source is a magnetically excited microwave plasma generated by an industrial magnetron. Emission is collected by a wide-range, low-noise CCD detector, enabling simultaneous measurement of analyte signals and background. Plug-and-play hardware features a torch loader for fast alignment and software-controlled air injection for organic matrices. The main components include:
- Agilent 4100 MP-AES microwave plasma-atomic emission spectrometer
- Agilent 4107 nitrogen generator for continuous gas-free plasma operation
- Agilent MP Expert software with application-specific method applets
- SPS 3 automated sample preparation system
- OneNeb universal nebulizer for high-solids and HF matrices
- Multimode Sample Introduction System (MSIS) for hydride and conventional aspiration
- External Gas Control Module (EGCM) to introduce air for organic sample analysis
Key Results and Discussion
The 4100 MP-AES achieves detection limits below parts-per-billion, outperforming flame AA in sensitivity and dynamic range. Cost-of-ownership analyses show gas-savings recoup initial investment within five months, with over USD 40,000 saved after 18 months for routine nine-element assays. Stability tests demonstrate <2% RSD over eight hours in organic solvents. Certified reference material analyses (tea leaves, rice flour, bovine liver) confirm accuracy for major and trace elements. Geological, agricultural, food and petrochemical matrices are processed without dilution, highlighting the system’s robustness.
Benefits and Practical Applications
Key advantages include:
- Lowest operating costs via air-run plasma and no standby gas or power use
- Improved safety by removing flammable and oxidizing gas handling
- High throughput with fast sample-to-sample times and unattended operation
- Plug-and-play installation and minimal user training requirements
- Wide analytical range suitable for mining, environmental, food, agriculture, chemical and petrochemical industries
Future Trends and Opportunities
Advances in field-deployable spectroscopy, integration with automated sample-prep platforms, and enhanced data connectivity to laboratory information management systems (LIMS) will further broaden MP-AES applications. Emerging opportunities include on-site geochemical analysis, real-time environmental monitoring, and coupling with machine-learning algorithms for predictive quality control. Continuous optimization of hydride generation and organic-matrix handling will expand the detectable element suite and lower detection thresholds.
Conclusion
The Agilent 4100 MP-AES establishes a new standard in atomic spectroscopy by combining high sensitivity, safety, and ultra-low operating costs. Its innovative magnetically excited microwave plasma source, gas-free design, and user-friendly software make it a versatile solution for laboratories seeking reliable, unattended multi-element analysis.
Reference
No external literature references were provided in the original material.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent 4200 Microwave Plasma-Atomic Emission Spectrometer
2015|Agilent Technologies|Brochures and specifications
Agilent 4200 Microwave Plasma-Atomic Emission Spectrometer CHANGE IS IN THE AIR AGILENT 4200 MP-AES RUNS ON AIR Analyze a broader range of samples while benefiting from the lowest cost of ownership. The safer, cost efficient Agilent 4200 MP-AES has higher…
Key words
torch, torchaes, aeselements, elementsyour, youryou, youcost, costanalysis, analysisloader, loaderagilent, agilentsamples, samplessoil, soilwavelength, wavelengthflic, fliceliminates, eliminatesflammable
Agilent 4210 MP-AES
2019|Agilent Technologies|Brochures and specifications
Elemental Analysis that Runs on Air Agilent 4210 MP-AES Runs on Air Elemental analysis using only air. The Agilent 4210 MP-AES has high sensitivity, detection limits down to sub ppb levels and is faster than conventional flame atomic absorption (AA).…
Key words
aes, aestorch, torchyou, youeliminates, eliminatescost, costflic, flicyour, youranalysis, analysiswavelength, wavelengthplasma, plasmasamples, samplesrange, rangeownership, ownershippreset, presetflammable
Microwave Plasma Atomic Emission Spectroscopy (MP-AES)
2021|Agilent Technologies|Guides
January 2021 Edition Microwave Plasma Atomic Emission Spectroscopy (MP-AES) Application eHandbook AGILENT TECHNOLOGIES Atomic Spectroscopy Solutions > Search entire document Table of contents How Microwave Plasma Atomic Emission Spectroscopy works 4 The benefits of MP-AES 6 Why switch from FAAS…
Key words
aes, aestechnologies, technologiesagilent, agilentelement, elementfaas, faasapplications, applicationswavelength, wavelengthagriculture, agriculturemicrowave, microwaveplasma, plasmanebulizer, nebulizersample, sampleatomic, atomicauto, autofood
Microwave Plasma Atomic Emission Spectroscopy (MP-AES) - Measuring metals in wine and food handbook
2022|Agilent Technologies|Guides
Microwave Plasma Atomic Emission Spectroscopy (MP-AES) Measuring metals in wine and food handbook Table of contents How Microwave Plasma Atomic Emission Spectroscopy works 3 The benefits of MP-AES 6 Why switch from FAAS to MP-AES? 7 Expanding capabilities with accessories…
Key words
return, returnaes, aespage, pagefaas, faascontents, contentssauvignon, sauvignoncabernet, cabernetwine, wineelement, elementmicrowave, microwaveplasma, plasmaatomic, atomiccounty, countysample, samplemdl