Mira P Raman - Product manual
Manuals | 2021 | MetrohmInstrumentation
Handheld Raman spectrometers like the Mira P enable rapid, nondestructive identification and verification of chemicals and pharmaceuticals in field conditions. Their small form factor combined with advanced Orbital Raster Scan (ORS) technology addresses growing demand for portable analytical tools in sectors such as quality control, law enforcement, environmental monitoring and on-site process verification.
This product manual aims to provide a comprehensive guide to the design, safe operation, configuration and maintenance of the Mira P instrument. It details multiple instrument models, required software, Smart Tip accessories, safety standards, installation procedures, operation workflows, troubleshooting, and technical specifications.
The core analytical method is Raman spectroscopy with high-power 785 nm laser excitation and ORS sampling. Mira P models (Basic, Advanced, Flex) differ by included Smart Tips and attachments. Key instrumentation components include:
The manual highlights:
Mira P offers:
Advances likely to enhance handheld Raman include:
The Mira P product manual delivers a structured roadmap for safe and effective use of a state-of-the-art handheld Raman spectrometer. By following the documented procedures for installation, calibration, operation and maintenance, laboratories and field operators can leverage ORS-based Raman analysis to achieve reliable, reproducible chemical verification across diverse applications.
Metrohm AG. Mira P Product Manual 8.0924.8001EN, 2021-04-20.
RAMAN Spectroscopy
IndustriesManufacturerMetrohm
Summary
Importance of Topic
Handheld Raman spectrometers like the Mira P enable rapid, nondestructive identification and verification of chemicals and pharmaceuticals in field conditions. Their small form factor combined with advanced Orbital Raster Scan (ORS) technology addresses growing demand for portable analytical tools in sectors such as quality control, law enforcement, environmental monitoring and on-site process verification.
Objectives and Study Overview
This product manual aims to provide a comprehensive guide to the design, safe operation, configuration and maintenance of the Mira P instrument. It details multiple instrument models, required software, Smart Tip accessories, safety standards, installation procedures, operation workflows, troubleshooting, and technical specifications.
Methodology and Instrumentation
The core analytical method is Raman spectroscopy with high-power 785 nm laser excitation and ORS sampling. Mira P models (Basic, Advanced, Flex) differ by included Smart Tips and attachments. Key instrumentation components include:
- Smart Tips for sampling: Calibrate/Verify Attachment (CVA), Short/Long/Extra-Long Working Distance lenses (SWD, LWD, XLWD), Vial and Tablet Holders, Contact Ball-Probe, Right Angle Attachment
- Mira Cal P software for instrument configuration, spectral library management, calibration and system suitability testing
- Battery or USB-powered operation with simple user interface via touchscreen and barcode reader
Main Features and Discussion
The manual highlights:
- Instrument description and model versions
- Safety classifications: laser Class 3B, IP67 sealing, MIL-STD-810G ruggedization
- Installation steps: battery change, USB connection, safe shutdown
- Operation workflow: user login, Smart Tip recognition, barcode scanning, measurement acquisition, on-instrument calibration and verification
- Maintenance recommendations: cleaning procedures, annual service intervals, disposal guidelines
- Comprehensive technical data: optical resolution, spectral range, laser output, environmental limits, dimensions and materials
Benefits and Practical Applications of the Method
Mira P offers:
- Rapid point-and-shoot analysis of solids and liquids without sample preparation
- Versatile sampling through multiple Smart Tips for containers, powders, films, tablets and direct contact
- On-site decision support in pharmaceutical QA/QC, hazardous material screening, food safety, petrochemical verification and forensic investigations
Future Trends and Potential Uses
Advances likely to enhance handheld Raman include:
- Miniaturized and more sensitive detectors for trace analysis
- Expanded chemometric libraries and machine-learning algorithms for automated compound identification
- Wireless cloud connectivity for remote data sharing and centralized spectral databases
- Integration with other portable techniques (e.g., infrared, fluorescence) for multimodal analysis
Conclusion
The Mira P product manual delivers a structured roadmap for safe and effective use of a state-of-the-art handheld Raman spectrometer. By following the documented procedures for installation, calibration, operation and maintenance, laboratories and field operators can leverage ORS-based Raman analysis to achieve reliable, reproducible chemical verification across diverse applications.
References
Metrohm AG. Mira P Product Manual 8.0924.8001EN, 2021-04-20.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Metrohm MIRA DS Product manual
2021|Metrohm|Manuals
MIRA DS 2.926.00XX Product manual 8.926.8001EN / 2021-09-15 Metrohm Raman 407 South 2nd Street Laramie, WY 82070 USA +1 307 460 2089 [email protected] www.metrohm.com MIRA DS 2.926.00XX Firmware version 8.0.3.40 or higher Product manual 8.926.8001EN / 2021-09-15 Technical Communication Metrohm…
Key words
laser, laserattachment, attachmentmira, mirawarning, warningnotice, noticesmart, smarttips, tipsoperation, operationdistance, distancepowerpack, powerpackworking, workingtip, tipselect, selectradiation, radiationusb
Metrohm MIRA XTR DS Product manual
2021|Metrohm|Manuals
MIRA XTR DS 2.926.01XX Product manual 8.0926.8005EN / 2021-09-15 Metrohm Raman 407 South 2nd Street Laramie, WY 82070 USA +1 307 460 2089 [email protected] www.metrohm.com MIRA XTR DS 2.926.01XX Firmware version 8.0.3.40 or higher Product manual 8.0926.8005EN / 2021-09-15 Technical…
Key words
attachment, attachmentlaser, lasermira, mirawarning, warningnotice, noticesmart, smarttips, tipsxtr, xtroperation, operationdistance, distancepowerpack, powerpackworking, workingtip, tipleft, leftacquiring
Metrohm Misa Raman - Product Manual
2020|Metrohm|Manuals
Misa Product Manual 8.950.8001EN / 2020-06-26 Metrohm AG Ionenstrasse CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Misa Firmware version 10.0.1.0 or higher Product Manual 8.950.8001EN / 2020-06-26 Technical Communication Metrohm…
Key words
misa, misawarning, warningcal, calnotice, noticebattery, batterysafety, safetyusb, usblaser, laserdanger, dangersmart, smartindicator, indicatortips, tipssers, sersradiation, radiationproduct
Mira Flex Packages
2019|Metrohm|Brochures and specifications
Mira Flex Packages Customized Metrohm Instant Raman Analyzers (Mira) for your unique applications Mira Flex – identification and verification of materials made fast and easy 02 Handheld Mira devices make identification and verification of materials fast, easy, and reliable –…
Key words
mira, miraflex, flexattachments, attachmentsattachment, attachmentraman, ramanverification, verificationcustomizable, customizablepackages, packagesstandoff, standofflaser, lasersmart, smartholder, holdersers, sersbags, bagsball