Metrohm MIRA Cal M Tutorial

Manuals | 2021 | MetrohmInstrumentation
Software, RAMAN Spectroscopy
Industries
Manufacturer
Metrohm

Summary

Significance of the topic


Portable Raman spectroscopy has become a critical tool for rapid, non-destructive chemical identification in field and laboratory environments. By combining handheld analyzers with mobile software, analysts gain unprecedented flexibility to perform real-time inspections, quality control, safety checks and regulatory compliance without returning to a central lab.

Objectives and overview


  • Provide a mobile interface (MIRA Cal M) for Android devices to configure and control Metrohm Raman instruments (MIRA XTR DS / MIRA DS).
  • Enable end-users to acquire and visualize Raman spectra, perform library matching and mixture analysis on the go.
  • Offer comprehensive sample management including metadata capture, editing, export and sharing.
  • Facilitate creation, import and maintenance of spectral libraries for accurate substance identification.

Methodology and instrumentation


The MIRA Cal M app communicates with the Raman analyzer via Bluetooth. Workflow steps include:
  • Instrument calibration using a certified standard and automated system suitability test.
  • Definition of acquisition procedures (integration time, laser power, averages, continuous or multi-scan modes).
  • Sample measurement with or without autofocus stand-off attachment; optional distance calculation and aiming laser.
  • In-app data transfer of spectra and metadata, automatic storage on the Android device.

Instrumentation used


  • Metrohm Instant Raman Analyzer MIRA XTR DS or MIRA DS
  • Android smartphone or tablet (OS 8.0 – 11.0)
  • Bluetooth® wireless connection
  • Certified Calibration Standard
  • Autofocus stand-off attachment with aiming laser
  • HazMasterG3® integration for hazardous substance reporting

Main results and discussion


  • Reliable Bluetooth pairing and PIN-protected connection ensure secure data exchange.
  • Calibration routine and system suitability checks validate instrument performance before sample measurements.
  • Flexible acquisition states support continuous scan, multi-scan and delayed measurement modes.
  • Real-time library matching and mixture analysis can run onboard the device or on the analyzer, then downloaded to the app.
  • Comprehensive sample viewer displays spectra, legends, full-screen mode, overlay, metadata (geolocation, photos) and supports reprocessing with local or onboard libraries.
  • Library management functions include viewing, creating, importing licensed/user libraries and editing sample metadata (CAS number, hazard data).
  • Data export options cover external storage, email, full or summary reports, and HazMasterG3® sensor data fusion.

Benefits and practical applications


  • Portability allows in-field chemical identification in security, environmental monitoring, pharmaceuticals, food safety and materials verification.
  • Rapid, on-site decision making reduces turnaround times and logistical costs of sample transport.
  • Integrated metadata capture (GPS, images, timestamps) enhances traceability and reporting.
  • Customizable procedures and library updates ensure adaptability to evolving analytical requirements.
  • Seamless integration with regulatory reporting software (HazMasterG3®) streamlines hazard assessment workflows.

Future trends and opportunities


  • Expansion to newer Android versions and cross-platform support (iOS).
  • Implementation of machine learning algorithms for advanced spectral deconvolution and unknown identification.
  • Cloud-based library synchronization and remote instrument monitoring.
  • Integration of additional sensor modalities (Raman combined with LIBS, NIR) in a unified mobile platform.
  • Enhanced user collaboration through real-time data sharing and secure networked databases.

Conclusion


The MIRA Cal M mobile application extends the power of handheld Raman analyzers by providing a comprehensive, user-friendly interface for calibration, acquisition, library management and data export. Its robust feature set and flexible architecture make it an essential tool for on-site chemical analysis, supporting faster decisions and improved safety across a range of industries.

References


  • Metrohm Raman. MIRA Cal M Tutorial 8.0105.8023EN, September 2021.
  • Metrohm Raman MIRA DS Manual 8.926.8001EN.
  • Metrohm Raman MIRA XTR DS Manual 8.0926.8005EN.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Metrohm MIRA XTR DS Product manual
MIRA XTR DS 2.926.01XX Product manual 8.0926.8005EN / 2021-09-15 Metrohm Raman 407 South 2nd Street Laramie, WY 82070 USA +1 307 460 2089 [email protected] www.metrohm.com MIRA XTR DS 2.926.01XX Firmware version 8.0.3.40 or higher Product manual 8.0926.8005EN / 2021-09-15 Technical…
Key words
mira, miraattachment, attachmentlaser, laserwarning, warningnotice, noticesmart, smarttips, tipsxtr, xtroperation, operationdistance, distancepowerpack, powerpackworking, workingtip, tipleft, leftacquiring
Metrohm MIRA Cal DS Tutorial
Metrohm MIRA Cal DS Tutorial
2021|Metrohm|Manuals
MIRA Cal DS MIRA Cal DS Tutorial 8.105.8069EN / 2021-09-15 Metrohm Raman 407 South 2nd Street Laramie, WY 82070 USA +1 307 460 2089 [email protected] www.metrohm.com MIRA Cal DS MIRA Cal DS 1.2.50 Tutorial 8.105.8069EN / 2021-09-15 Technical Communication Metrohm…
Key words
mira, miraxtr, xtrcal, calwarning, warningnotice, noticeoperating, operatinglibraries, librariesdanger, dangerview, viewuser, usersettings, settingslibrary, libraryreports, reportshome, homesynchronize
Metrohm MIRA DS Product manual
Metrohm MIRA DS Product manual
2021|Metrohm|Manuals
MIRA DS 2.926.00XX Product manual 8.926.8001EN / 2021-09-15 Metrohm Raman 407 South 2nd Street Laramie, WY 82070 USA +1 307 460 2089 [email protected] www.metrohm.com MIRA DS 2.926.00XX Firmware version 8.0.3.40 or higher Product manual 8.926.8001EN / 2021-09-15 Technical Communication Metrohm…
Key words
laser, laserattachment, attachmentmira, mirawarning, warningnotice, noticesmart, smarttips, tipsoperation, operationdistance, distancepowerpack, powerpackworking, workingtip, tipselect, selectusb, usbradiation
Misa Cal M software - Tutorial
Misa Cal M software - Tutorial
2020|Metrohm|Manuals
Misa Cal M Tutorial 8.0105.8025EN / 2020-06-26 Metrohm AG Ionenstrasse CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Misa Cal M 1.1.0 or higher Tutorial 8.0105.8025EN / 2020-06-26 Technical Communication Metrohm…
Key words
misa, misacal, callibraries, librarieswarning, warningnotice, noticeoperating, operatingtab, tabimporting, importingsers, sersdanger, dangeroverview, overviewlicensed, licensedsafety, safetymenu, menuprocedures
Other projects
GCMS
LCMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike