Single-protein optical holography

Tu, 10.9.2024
| Original article from: Nat. Photon. 18, 388–395 (2024)
In the article published recently in Nature Photonics, the researchers reported significant improvement in sensitivity of detecting single protein molecule by methods of optical holography.
<ul><li><strong>Photo: </strong><i>Nat. Photon.</i> <strong>18</strong>, 388–395 (2024): <strong>Fig. 4:</strong> Phase-sensitive microscopy of single-proteins. a, Oblique angle of illumination imprints a phase gradient onto the scattered light as a function of landing position. b, Phase values of landing events versus landing position (black data points). The subtraction of a linear phase gradient removes the spatial dependence of the phase (red data points). c, Relative phase of each landing event versus its contrast. The red areas depict a Gaussian kernel density estimation of the data via violin plots. Each violin plot was separately generated for each oligomer. d, Zoomed-in view of the data shown in c. The grey data points are the raw data, whereas red represents the average of each oligomeric distribution together with its standard error.</li></ul>
  • Photo: Nat. Photon. 18, 388–395 (2024): Fig. 4: Phase-sensitive microscopy of single-proteins. a, Oblique angle of illumination imprints a phase gradient onto the scattered light as a function of landing position. b, Phase values of landing events versus landing position (black data points). The subtraction of a linear phase gradient removes the spatial dependence of the phase (red data points). c, Relative phase of each landing event versus its contrast. The red areas depict a Gaussian kernel density estimation of the data via violin plots. Each violin plot was separately generated for each oligomer. d, Zoomed-in view of the data shown in c. The grey data points are the raw data, whereas red represents the average of each oligomeric distribution together with its standard error.

In the research article published recently in Nature Photonics journal, the researchers from the University of Oxford, UK reported significant improvement in sensitivity of detecting single protein molecule by methods of optical holography.

This study explores light scattering by nanoscale objects, focusing on improving the sensitivity of single-molecule detection. Using a non-common-path geometry in a dark-field scattering microscope, similar to a Mach–Zehnder interferometer, the researchers achieve a significant improvement in sensitivity. This setup separates the scattering and reference light into four phase-stable channels, increasing sensitivity by five orders of magnitude compared to current holographic methods. The technique allows for the detection and mass measurement of single proteins with mass below 100 kDa, while also providing detailed insights into the polarizability of biomolecules.

The original article

Single-protein optical holography

Thiele, J.C., Pfitzner, E. & Kukura, P.

Nat. Photon. 18, 388–395 (2024)

https://doi.org/10.1038/s41566-024-01405-2

licensed under CC-BY 4.0
Selected sections from the article follow.

Abstract

Light scattering by nanoscale objects is a fundamental physical property defined by their scattering cross-section and thus polarizability. Over the past decade, a number of studies have demonstrated single-molecule sensitivity by imaging the interference between scattering from the object of interest and a reference field. This approach has enabled mass measurement of single biomolecules in solution owing to the linear scaling of image contrast with molecular polarizability. Nevertheless, all implementations so far are based on a common-path interferometer and cannot separate and independently tune the reference and scattered light fields, thereby prohibiting access to the rich toolbox available to holographic imaging. Here we demonstrate comparable sensitivity using a non-common-path geometry based on a dark-field scattering microscope, similar to a Mach–Zehnder interferometer. We separate the scattering and reference light into four parallel, inherently phase-stable detection channels, delivering a five orders of magnitude boost in sensitivity in terms of scattering cross-section over state-of-the-art holographic methods. We demonstrate the detection, resolution and mass measurement of single proteins with mass below 100 kDa. Separate amplitude and phase measurements also yield direct information on sample identity and experimental determination of the polarizability of single biomolecules.

Main

A core challenge of optical microscopy is to generate detectable image contrast arising from micro- or nanoscopic objects and features. One of the most powerful methods in this regard relies on the phase-contrast concept originally introduced by Zernike, which paved the way towards highly sensitive imaging of phase objects. Here incident light and light scattered by an object are considered to correspond to the two arms of an interferometer, where the addition of a π/2 phase shift to the scattered light results in an amplitude modulation, which can be imaged1,2. Limitations associated with this initial approach spurred the emergence of numerous variations of the original concept to enable more quantitative measurements3, as well as phase-shifting interferometry where multiple images are recorded to enable phase and amplitude imaging4,5,6. Further developments include digital holography and quantitative phase imaging, as well as alternative implementations optimized for nanoparticle imaging, tracking and characterization7,8,9,10. Regarding sensitivity, recent advances have reached single metallic nanoparticles as small as 20 nm in imaging11,12,13,14 and 15 nm in differential interference measurements15. Common-path interferometry has been shown to yield holographic information as well16, although it requires recording an image sequence of the same particle, which limits the sensitivity to particles clearly visible above any static background, such as that of regularly used glass coverslips17.

Despite their unique capabilities, these efforts have struggled to match the sensitivities achieved with non-holographic, common-path interferometric approaches, which have focused on imaging and quantifying phenomena at interfaces with high sensitivity18,19. The introduction of laser illumination dramatically improved the sensitivity by increasing the illumination power densities, lowering shot noise and enhancing spatiotemporal coherence of illumination. This enabled access to the nanoscale down to 5 nm gold nanoparticles (AuNPs) in the form of interferometric scattering microscopy20 and ultimately individual biomolecules21,22. The latter has recently demonstrated a substantial impact on the characterization of biomolecular structures, dynamics and interactions through the development of mass photometry23,24,25,26. A direct consequence of common-path imaging, however, is the difficulty to modify the reference field relative to the scattered field, causing a loss of phase information.

Here we combine sample illumination by total internal reflection with optical quadrature detection27, achieving single-molecule sensitivity reported so far only for common-path approaches. In analogy to a time-domain lock-in amplifier, which mixes sinusoidal waveforms with the modulated signal, we mix four reference fields of the same colour but different phase shifts with the scattered field to retrieve the complex amplitude of the scattered field. As a result, we measure the complex optical field of sub-diffraction particles, that is, AuNPs and single proteins. Therefore, we can experimentally quantify the polarizability of individual biomolecules, implement holography-specific capabilities such as optimizing the focus in post-processing28 and demonstrate a step change in the sensitivity achievable with holographic imaging.

Results

Proof of concept

Our microscope is based on a Mach–Zehnder interferometer where a scattering object is located in one arm and the reference travels separately along the other arm (Fig. 1a). Placing a quarter-wave plate at 45° in the reference arm generates equal amounts of vertical (v)- and horizontal (h)-polarized light with a relative phase shift of π/2. Similarly, a half-wave plate in the scattering arm at 22.5° produces equal amounts of v- and h-polarized light with a relative phase shift of π. Recombination by a non-polarizing beamsplitter (NPBS) generates four phase-shifted interferograms: two interferograms in one arm where the h and v polarizations contain phase shifts of 0 and π/2, respectively. In the other arm, the two orthogonal polarizations contain interferograms with the corresponding phase shifts of π and 3π/2. The individual interferograms are then split by two polarizing beamsplitters (PBSs) and imaged onto four individual cameras, which are read synchronously.

Nat. Photon. 18, 388–395 (2024): Fig. a, Output from a single-emitter laser diode is split by an anti-reflection-coated window. One part is focused onto an NBK7 prism to illuminate the sample. The scattered light is collected by a ×60 water-dipping objective. The other part is mode filtered with a 25 µm pinhole and mixed with scattered light after introducing different phase shifts to two orthogonal polarizations. The interference of reference and scattered light is detected for each phase shift by a separate camera. Note that the PBS after the objective reflects light out of the image plane and transmits the vertical polarization. PBS, polarizing beamsplitter; NPBS, non-polarizing beamsplitter; QWP/HWP, quarter-/half-wave plate; M, mirror; NA, numerical aperture. b, Illustration of an ideal measurement in the absence of substrate roughness. Depending on the phase shift, constructive or destructive interference is observed. Combining four images with the correct phase shifts reconstructs the amplitude and phase of the scattered field (bottom). Supplementary Information provides details of the calculation. c, Representative raw data of 40 nm AuNPs detected by the four cameras after subtraction of any non-interferometric terms. d, Reconstructed amplitude (top) and relative phase (bottom) of the electric field. e, Intensity of 40 nm AuNPs derived via holography (top) and directly derived by dark-field microscopy. 1: Total-internal-reflection optical quadrature microscopy.

This approach has several benefits. (1) Total-internal-reflection illumination enhances the illumination field strength at the interface and suppresses scattering from objects more than a few hundred nanometres from the interface, effectively reducing the sample-induced background. Crucially, total internal reflection almost completely extinguishes illumination light reaching the detector, except for that scattered by interface imperfections. (2) The relative amplitude of scattered and reference light can be easily adjusted to match the full-well capacity of the imaging cameras at the desired read-out speed, as well as to the expected scattering cross-sections of the sample. (3) The approach is inherently phase stable, despite a non-common-path geometry, because any phase differences identically propagate through all the channels, resulting in an excellent overall phase stability. (4) Individual blocking of either arm separately yields the reference intensity, scattering intensity and interference of both fields.

Each camera j, thus, records the interference of scattered and reference fields:

(1)    \({I}_{j}^{\;{\rm{cam}}}={|{E}_{{\rm{ref}}}|}^{2}+{|{E}_{{\rm{scat}}}|}^{2}+\) \(2|{E}_{{\rm{ref}}}||{E}_{{\rm{scat}}}|\cos (\Delta \varphi +\Delta {\varPhi }_{j}),\)

where ΔΦj is the additional phase shift introduced by the half- and quarter-wave plates in front of the NPBS. In other words, each camera records an interferogram of different phase shifts \(\Delta {\varPhi }_{j}\in\left[0,\frac{\pi }{2},\pi ,\frac{3\pi }{2}\right]\)(Fig. 1b), where the scattered light of each particle interferes differently with the reference field on all four cameras. To obtain the desired term |Escat|cos(Δφ + ΔΦj), we subtract any non-interferometric terms from each image (reference field |Eref|2 and scattering field |Escat|2) and normalize by |Eref|. The reference and scattered fields are directly recorded before measuring the interference of both by blocking either the scattering or the reference path. The resulting images are then combined in a complex fashion according to their phase shifts, by multiplying the corrected output of camera j by exp(iΔΦj) and computing their average, generating the final complex-valued holographic image. The processing illustrated in Supplementary Fig. 1 restores the complex-valued scattered field Escat represented by its amplitude and phase (Fig. 1b (bottom) and experimental data in Fig. 1c), which allows us to generate the respective amplitude and relative phase images (Fig. 1d). Due to the unknown illumination phase, we only obtain a relative phase and not an absolute one. Reassuringly, the scattered intensity derived via the square of the holographically reconstructed scattered field \({\left|{E}_{{{\rm{scat}}}}^{{\;{\rm{holo}}}}\right|}^{2}\) is identical in both appearance and intensity to the dark-field intensity \({\left|{E}_{{{\rm{scat}}}}^{{\;{\rm{DF}}}}\right|}^{2}\) of the same field of view recorded with identical acquisition parameters by blocking the reference arm (Fig. 1e). These results demonstrate that our approach indeed accurately extracts the scattering amplitude, with a deviation of only ~20% probably stemming from imperfect coherence between the reference and scattered fields. This constant scaling can be compensated with a calibration if absolute values for the scattered field are desired. With a laser coherence length of approximately 150 μm (Supplementary Fig. 2), we ensure a consistent degree of interference over the field of view and avoid background interference from additional reflections. We normalized all data to exposure time and laser power to ensure comparability between different experimental settings.

Demonstration of amplitude and phase decoupling

Having verified that we can retrieve the correct scattering intensity, we turn to the accuracy of our amplitude and phase measurements. To achieve this, we record videos where we temporally vary the phase between the scattering and reference arms in a linear fashion by a piezo-driven mirror in the scattering/illumination arm (Fig. 1a). The intensity of individual particles as a function of time reveals clear oscillatory behaviour (Fig. 2a,b). This is caused by the interference between the scattered field of each particle and the reference, which exhibits a constant phase shift ΔΦj and an additional temporally modulated phase shift, resulting in a global phase shift Δφ(t) between the fields. Following the intensity of a particular particle (Fig. 2a, black circle) on all four cameras reveals sinusoidal modulations shifted by \(\frac{\pi }{2},\pi \,{\rm{and}}\,\frac{3\pi }{2}\) relative to the first camera (blue trace). Despite the fact that the intensity in the individual camera images varies by ±100%, the reconstruction of the complex-valued scattered field yields a constant amplitude with a standard deviation of only 0.31%, demonstrating excellent separation of phase and amplitude. A residual variation in the amplitude might be related to imperfect circular and linear polarization states generated by the quarter- and half-wave plates, respectively, leading to phase shifts between the scattered and reference fields deviating slightly from multiples of \(\frac{\pi }{2}\) (Supplementary Fig. 3). The phase ramps down linearly as introduced by the movable mirror. The same behaviour can be observed for all the other particles in the region of interest (Fig. 2c,d, light traces). Additional measurements without phase ramping (Supplementary Fig. 4) confirm the high overall phase stability with a fluctuation of only a few milliradians per second.

Nat. Photon. 18, 388–395 (2024):Fig. 2: Holography of 40 nm AuNPs and resulting amplitude and phase decoupling. a, Images of four cameras (phase shifts 0, π/2, π and 3π/2) with different phase shifts introduced by a movable mirror in the illumination arm. b, Temporal evolution of the detected interference of a single AuNP (black circle in a). Each trace corresponds to a different camera. c,d, Reconstructed amplitude (c) and relative phase (d). The black trace corresponds to the highlighted AuNP and the lighter-coloured ones, to the other particles in the field of view. The black amplitude trace has a relative standard deviation of 0.31%.

Optical holography of individual proteins

Given these encouraging results, we queried to which degree this approach may be suited to detect, image and quantify very weak scatterers, such as individual proteins. A cleaned microscope glass coverslip produces a speckle pattern (Fig. 3a) reminiscent of that observed in iSCAT29 and high-performance dark-field microscopy30. Again, the dark-field and holographically reconstructed images show excellent quantitative agreement. Introducing ~40 nM of a soluble 90 kDa protein (DynΔPRD) results in no discernible changes to the amplitude images as a function of time (Fig. 3b). Computing the differences of the mean of two moving subsequent windows with a length of ten frames (6.25 ms per frame), however, reveals clear signatures of individual proteins binding to the surface in both amplitude and phase (Fig. 3c). We then quantified the contrast of each landed protein by fitting a complex-valued point spread function (PSF) model derived from the average PSF of all the landing events (Fig. 3d and Methods).

Nat. Photon. 18, 388–395 (2024): Fig. 3: Single-protein holography. a, Dark-field and holographically reconstructed intensity and phase maps of a microscope coverslip exhibiting typical residual glass roughness. b, Amplitude image of the glass surface does not visibly change before and after a single protein landed. c, Moving mean differences of subsequent image stacks reveal individual proteins landing in the amplitude and phase representations. d, Amplitude histograms (grey) of the landing events from individual videos acquired over 120 s. The red line represents a fit of four Gaussians to the averaged data shown in black. e, Fitted contrast versus sequence mass of the different oligomers. The red line indicates a linear fit to the data points. The error bars give the standard error across three measurements and are in the order of the data point size.

The resulting histogram exhibits several sub-distributions, corresponding to the monomer, dimer, tetramer and hexamer of dynamin (DynΔPRD), as reported recently25. Their fitted masses correlate well with the expected molecular weights of 90, 180, 360 and 540 kDa (Fig. 3e). The linear relationship between contrast and molecular weight allows us to deduce the mass of any unknown protein based on its image contrast, with an average mass resolution of 28 kDa. Although this mass resolution is slightly higher compared with state-of-the-art mass photometry24, we expect substantial improvements achievable by optimizing the illumination power and geometry.

In principle, we could also derive the scattering intensity by collecting the dark-field scattering (Fig. 1e). Supplementary Fig. 5 shows the PSF and histogram of protein landing events at the same glass spot generated via holography and synthetic dark field. It is apparent that only the interferometric approach yields well-defined events, whereas the PSFs are distorted for dark-field imaging. As explained in the Supplementary Information, in dark-field operation, the scattered field interferes with the complicated wavefront of light scattered by the glass interface, which prevents an accurate contrast estimate.

Until now, we only investigated the amplitude of landing events. However, we simultaneously derive the phase shift associated with each event. The oblique illumination associated with total internal reflection imprints a linear phase gradient onto the illumination field (Fig. 4a). This gradient is corrected (Fig. 4b) by subtracting a position-dependent phase from each landing event (Supplementary Information).

Nat. Photon. 18, 388–395 (2024): Fig. 4: Phase-sensitive microscopy of single-proteins. a, Oblique angle of illumination imprints a phase gradient onto the scattered light as a function of landing position. b, Phase values of landing events versus landing position (black data points). The subtraction of a linear phase gradient removes the spatial dependence of the phase (red data points). c, Relative phase of each landing event versus its contrast. The red areas depict a Gaussian kernel density estimation of the data via violin plots. Each violin plot was separately generated for each oligomer. d, Zoomed-in view of the data shown in c. The grey data points are the raw data, whereas red represents the average of each oligomeric distribution together with its standard error.

The corrected phase of all the individual oligomeric species falls onto a line, as expected for a non-absorbing dielectric nanoparticle (Fig. 4c)12. As confirmed by the simulation (Supplementary Fig. 8), the corrected phase becomes less well defined as the contrast of the particle becomes lower, due to decreasing localization precision. Note that we are not able to derive the absolute phase of the landing particles as we lack knowledge about the phase relation between the illumination and reference fields. Zooming into the data along the phase axis (Fig. 4d) reveals a slight but steady increase in the relative phase with increasing contrast. This is to be expected, since the centre of mass of heavier and thus larger particles will be further separated from the interface compared with lighter particles. Furthermore, knowledge of the complex scattered field enables us to change the focus during data analysis (Supplementary Fig. 9a,b and Supplementary Information)31. The standard deviation derived from the differential amplitude data correlates well with the contrast to mass conversion (Supplementary Fig. 9c). We exploit this to automatically optimize the focus for all our measurements to maximize the imaging contrast in post-processing.

Measurement of the polarizability of a single protein

Our holographic approach independently quantifies the scattered field of any unknown phase and optimizes focusing during post-processing, both for AuNPs and dielectric proteins. We use these capabilities to derive an experimental estimate for the polarizability of a protein attached to a glass coverslip per molecular weight, which we will call the specific polarizability. As a calibration, we first measure the contrast of static AuNPs of different diameters (20, 40 and 60 nm), because their polarizability is well understood and characterized. The contrast is normalized to exposure time and laser power, which we reduced for the larger AuNPs (40 and 60 nm). We did not use smaller AuNPs to ensure clear visibility above the coverglass background.

As long as Rayleigh scattering dominates, the holographic contrast depends on |Escat| αVr3, whereas the dark-field contrast is described by |Escat|2α2V2r6. Therefore, plotting the third root of the holographic data (Fig. 5a) and sixth root of the dark-field data (Fig. 5b) linearizes the values with respect to the particle radius r. The linear scaling of the mean values of c1/3 and c1/6, respectively, again indicates the agreement of the retrieved scattering amplitude with theoretical predictions. The values gathered via dark-field microscopy are 20% (in intensity) and 3% (in (intensity)1/6) larger than the values retrieved by holography, consistent with imperfect coherence (Fig. 1e).

Nat. Photon. 18, 388–395 (2024): Fig. 5: Quantification of the polarizability of a single protein. a,b, Histogram of the third root of the holographically derived particle contrast (a) and sixth root of particle contrast derived from dark-field images for 20, 40 and 60 nm AuNPs (b). c, Calibration of the scattering cross-section using AuNPs. The blue data points are the holographically derived contrasts (a) versus their scattering cross-section calculated using Mie theory. The grey line is a one-parameter linear fit to the sixth root of the scattering cross-section. The black lines indicate the measured contrast of our oligomeric protein sample. d, Based on the calibration in c, we can plot the scattering cross-section of proteins (red dashed lines) versus their theoretical molecular weight (blue data points). The solid line represents a fit of equation (2) to the data.

For each particle size, we calculate a scattering cross-section (Fig. 5c) by assuming the AuNPs to be homogeneous and embedded in a homogeneous medium of refractive index n = 1.337. As previously shown32, the scattering cross-section of the AuNPs used here (ranging from 20 to 60 nm) can be well estimated by Mie scattering. By performing a one-parameter linear regression on the derived scattering cross-section against our measured contrast, we estimate the scattering cross-section of the measured protein, assuming equal collection efficiency and near-field enhancement in total-internal-reflection illumination33 for AuNPs and proteins (Fig. 5d). We assume the scattering of the protein to be well described by the Rayleigh scattering of a dielectric particle34:

(2)    \({\sigma }_{{\rm{scat}}}=\frac{1}{6\pi }{\left(\frac{2\pi {n}_{{\rm{m}}}}{{\lambda }_{0}}\right)}^{4}{{\rm{\alpha }}}^{2}.\)

Fitting the scattering cross-section of the protein to equation (2) yields a specific excess polarizability α per molecular weight of 239 ± 4 Å3 kDa–1. The statistical error is propagated from the standard deviations of the fit parameters. Assuming a specific volume of 0.7446 ml g–1 (refs. 24,35), we can estimate the refractive index of the protein to n = 1.47. Both these values—specific polarizability and refractive index—are well within the range of values reported previously in the literature36,37,38, although somewhat smaller than that recently calculated using an atomic polarizability model39. We remark that this polarizability measurement by comparison with AuNPs is distinct to similar efforts made with a common-path geometry, like iSCAT or mass photometry, because they only yield an intensity, convolving amplitude and phase contributions, with the phase generally being ill-defined. This is a consequence of the Gouy phase contribution of both scattered and reflected light, which is difficult to accurately quantify when performing experiments with single-molecule sensitivity. Furthermore, a precise evaluation of the scattered phase shift for nanoparticles >30 nm is non-trivial due to contributions from path-length variations and scattering phase.

Discussion

Using an inherently phase-stable approach, we have demonstrated holographic imaging with a sensitivity reaching single biomolecules with an average mass resolution of 28 kDa and a dynamic range beyond 103 in terms of holographic contrast. Although the approach was currently unable to match the sensitivity and measurement precision achievable with mass photometry, there are clear routes to potential future improvements. First, our current experimental arrangement was limited to a power density of 50 kW cm–2, an order of magnitude lower than in mass photometry, resulting in a loss of shot-noise-limited sensitivity. Additionally, we did not yet optimize the electric-field enhancement due to field confinement through total internal reflection as a function of incidence angle, resulting in a relatively low 10% enhancement compared with the in-principle-achievable factor of three in intensity33.

This confinement-induced increase in incident intensity at the detection interface will increase sample scattering for a constant power entering the sample. In addition, we expect a reduction in background scattering arising from a non-penetrating field, improvement in contrast through the ability to optimize the phase difference between scattered and reference light, reduction in image noise due to a lack of beam scanning and shot noise background optimization by matching the image intensity to camera capabilities. Furthermore, the illumination phase gradient has the potential to reduce coherent background by distribution over all the channels. Illumination with a rapidly scanned standing wave together with active phase modulation, similar to structured illumination microscopy40 or modulated localization microscopy41, would enable a constant-illumination phase and therefore eliminate the current phase uncertainty caused by limited localization precision. Additionally, a bleed-through channel via the scattering arm would enable the measurements of the absolute scattering phase. This could be realized by immobilizing dielectric nanoparticles that would offer precise control over the density and scattering strength. We expect that these future improvements have the potential to deliver sensitivity and mass resolution of single-molecule mass measurement beyond those achievable with far-field, common-path geometries. Furthermore, the use of a prism as a sample substrate provides an avenue towards the realistic use of atomically flat substrates, which would reduce or even eliminate optical background and associated mass broadening.

Taken together, we have presented an implementation of optical quadrature microscopy in combination with total-internal-reflection illumination capable of holographic imaging of single biomolecules. We verified our approach by showcasing the ability to separate the amplitude and phase of the scattered field and confirmed its quantification by a direct comparison with dark-field microscopy. The resulting sensitivity enables the imaging of individual biomolecules, which can be converted into a measurement of the polarizability of a single protein based on the scattering of a well-characterized reference object. These results break new ground for optical holography, providing access to the exciting sub-20 nm length scale for phase and amplitude imaging with applications in the biological, physical and materials sciences. Among others, our method will enable the detailed optical characterization of quantum and carbon dots, differentiation of AuNPs with different shapes and distance measurements of single particles and proteins on the nanometre scale.

Methods

Setup

The optical setup used in this study is similar to previously reported optical quadrature microscopes27,42. A schematic of the setup is shown in Fig. 1a and Supplementary Fig. 10 shows a photograph. A single-emitter laser diode (450 nm, 500 mW, NDB4816, Nichia) is mounted in a temperature-controlled mount (Thorlabs, 400 mA, 17 °C) and collimated using an aspheric lens (f = 3.30 mm, N414TM-A, Thorlabs). The polarization is vertically aligned using the light reflected off a PBS (PBS251, Thorlabs) and guided to an anti-reflection-coated NBK7 window (WW11050-A, Thorlabs), which picks up ~0.5% of incident power and reflects it into the reference arm. More than 99% of light propagates towards the prism (12.7 mm Littrow prism (90-60-30), Edmund Optics) and is focused into the focal plane of the objective using an achromatic lens (f = 60 mm, AC254-60-A, Thorlabs). Standard glass coverslips (24 × 75 mm2; thickness, 1.5; Carl Roth) are optically coupled to the prism by immersion oil (n = 1.52) to enable the fast exchange of samples without the need for cleaning the prism. Scattered light from the coverslip surface is collected using an objective (×60, 1.1 numerical aperture, water dipping, Olympus) and is imaged onto four different cameras by an achromatic tube lens (f = 300 mm, AC254-300-A, Thorlabs). It is important to note that the tube lens is placed one focal length away from the back focal plane of the objective to create a flat wavefront in the image plane. The light reflected towards the reference arm is focused by an achromatic lens (f = 50 mm, AC254-50-A, Thorlabs) onto a 25 µm pinhole (P25CB, Thorlabs) to filter the mode of the laser. The diverging light is then collimated by the tube lens.

The central elements of this optical scheme are the two wave plates in front of the NPBS: the two orthogonal polarizations of the reference arm are phase shifted by a quartz quarter-wave plate (WPQ05M-445, Thorlabs), resulting in a phase shift of 0 and π/2 for h and v polarizations, respectively. External reflection off the NPBS introduces an additional phase shift of π, whereas the transmitted polarizations are not affected. Light coming from the scattering arm propagates through the polymer half-wave plate (WPH05ME-445, Thorlabs), which introduces 0 and π phase shifts to the two orthogonal polarizations. Mixing the reference and scattering light at the NPBS and separating them via a PBS allows to create an image with the relative phase shifts of 0, π/2, π and 3π/2. The four cameras (Grasshopper GS3-U3-23S6M-C, Teledyne FLIR) detect the four phase-shifted images at 800 frames per second in a synchronized fashion. Five consecutive frames are averaged, and the data from all the cameras are aligned to the first camera (affine transformation: scale, shift, rotation) followed by a 2.0 × 2.0 px2 binning, resulting in an effective pixel size of 117.2 nm.

To find and maintain focus in all the measurements, a collimated laser beam (0.5 mW, 520 nm, Thorlabs) propagates through the back aperture of the objective. The light is focused onto the coverslip–buffer interface. The reflected light is collimated and imaged by a camera through a 50/50 NPBS. The radius of the resulting circle is maintained by a proportional–integral–derivative controller that controls the axial distance between the objective and coverslip. All data acquisition and control is handled by a custom-built LabVIEW (LabVIEW 2018 SP1, National Instruments) program.

To achieve a phase-stable interferometer, we considered the following details as critical. (1) The beam path was chosen to be as low as 52 mm to minimize thermal drifts and mechanical vibrations. (2) All the core components of the interferometer (except the sample stage) were interconnected with a 30 mm cage system to further minimize the relative motion of optical components over time. (3) Where possible, the beam path was covered with plastic covers clipped into the rods of the cage system (C30L24, Thorlabs) to minimize air density fluctuations. (4) A separate cover was placed to house the whole microscope to further minimize air density fluctuations. (5) The temperature of the laser diode mount was equilibrated after switching on the emission for at least 30 min.

AuNP samples

All AuNPs were purchased from NanoPartz (A11-20-CIT-DIH-1-10, A11-40-CIT-DIH-1-10 and A11-60-CIT-DIH-1-10). First, clean coverslips were rendered hydrophilic by placing them in an O2 plasma for 30 s (30% power, 0.5 mbar O2, Zepto-BRS 200, Diener electronic). For all sizes of AuNPs, 10 µl was spin coated onto the hydrophilic coverslips for 18 s at 500 r.p.m. and 18 s and 60 s at 1,400 r.p.m. A polydimethylsiloxane gasket (CultureWell CW-8R-1.0, Grace Bio-Labs) was placed at the centre of the coverslip and 50 µl MilliQ water was added to achieve immersion with the objective lens.

Protein landing assay

DynΔPRD25 was diluted 25–50 fold from its stock concentration to 80–40 nM before replacing the droplet for immersion with the diluted solution. Landing events were recorded for 2 min after replacing the immersion solution.

Data analysis

All the analysis was performed in custom Python scripts43. Raw data were first aligned by finding an affine transform, which minimizes the least squares of the differences of the aligned and target images. We used only the scattered intensity for aligning the four channels since it showed higher contrast than the interferometric measurement and resulted in a more reliable alignment. The data were then pixel binned (2 × 2 binning) and normalized to the exposure time and laser power. To extract the complex scattered field of static images, first the reference image and dark field (both recorded shortly before acquiring the holographic data) were subtracted. To extract the scattered field only, the resulting image was divided by the square root of the reference image. The resulting image now only contains 2|Escat|cos(Φj) projected along the positive and negative real and imaginary axes of a complex plane. By averaging the four images rotated all onto the positive real axis, the complex field Escat is recovered.

For static measurements, particles were detected on the absolute of the reconstructed scattering field |Escat| by calculating a radial symmetry map (α = 1.0, radius = 3 px)44 and finding the local maxima with radial symmetry above the 99% quantile of the map.

Fitting static particles with the analytic PSF model

For fitting the scattered field of particles, the following complex-valued PSF model was used:

(3)    \(E(r,\varphi )=|{E}_{0}|\left(\frac{2{J}_{1}\left(\frac{r}{\sigma }\right)}{\frac{r}{\sigma }}\exp\Big({\rm{i}}\varphi\Big)\right),\)

where J1 denotes the Bessel function of the first kind; σ, the width; r, the distance from the centre; |E0|, the amplitude; and φ, the phase of the landing event. The squared residuals (SR) of the sum of the real and imaginary parts of the PSFs were used as an objective function for minimization by optimizing x, y, |E0| and φ:

(4)    \({{\rm{SR}}}={\mathrm{Re}\left\{{{\rm{data}}}-E\left(x,y\right)\right\}}^{2}+\) \({{{\rm{Im}}}\left\{{{\rm{data}}}-E\left(x,y\right)\right\}}^{2}.\)

For the data presented in Figs. 2c,d and 5a, the measurements of immobilized nanoparticles were analysed during which the length of the sample path was varied with a piezo-shifted mirror to introduce a phase shift. A segment of the measurement where the phase shift linearly increased by 6π was selected; the particles were detected on a sum of |Escat| over all the phase shifts. A 23 × 23 px2 thumbnail was independently fitted with the complex PSF for each phase shift. For Fig. 5a, the cubic roots of the amplitudes were averaged over all the phase shifts and particles, with a relative standard deviation of the cubic root of the amplitude above 10% or a standard deviation of the position above 0.2 px was rejected.

The dark-field measurements of immobilized nanoparticles were analysed in a similar way. For the particle fitting, the scattered intensity |Escat|2 was independently fitted with an intensity PSF (square of the complex PSF in equation (3)) in all the four channels. For Fig. 5b, the sixth roots of the amplitudes were averaged over all the channels and particles, with a relative standard deviation of the sixth root of the amplitude above 10% or a standard deviation of the position above 0.2 px was rejected.

For dynamic videos (that is, landing events of proteins), only the reference image was subtracted. The resulting image was divided by the square root of the reference and the complex video was calculated by complex summation (Fig. 1). Temporal phase changes were corrected by applying the phase shift θcorr, which minimizes the difference to the first frame.

(5)    \(\mathop{\min }\limits_{{\theta }_{{{\rm{corr}}}}}\left(\big|\left|{E}_{{{\rm{scat}}}}\left(t\right)\right|-\left|{E}_{{{\rm{scat}}}}\left(t=0\right)\right|\big|\right)\)

The corrected complex video was then further analysed by a sliding difference of ten-frame window length to remove static features like the glass roughness and other proteins that landed before the analysed window. As shown in Supplementary Fig. 11, the phase correction reduces the noise in the differential images.

Detection and fitting of protein landing events

For detecting the position and time of the landing events, a normalized cross-correlation with a complex PSF (equation (3)) was applied to the video followed by a maximum filter. The resulting mask was then multiplied by the previous normalized cross-correlation and thresholded at 0.15. This essentially gives the first approximation of the location and time of all the landing events. We then convolved the mask with a circle of radius 2 along the spatial axes and a pulse function along the temporal axis with a length of ten frames to blur the found particle locations. We then searched for the local maximum of the scattering amplitude in this mask, which we define as the landing position and time.

Next, we created an experimental PSF model from the found events to compensate for potential aberrations. First, a 23 × 23 px2 thumbnail at the detected landing event position was fitted by the complex PSF model (equation (3)), as described above, to find the refined spatial coordinates for all the determined landing events. Coordinates that deviated by more than 1 px from their initial guess were discarded to suppress outliers from entering the experimental PSF model. Then, 23 × 23 px2 thumbnails at the refined and filtered positions were averaged in a complex manner, generating an average PSF. The average PSF was then interpolated to create a complex-valued experimental PSF model, which we used to fit the individual thumbnails found at the refined positions minimizing the SR as described above (equation (4)). The events contributing to the histogram were filtered according to position precision (fit position closer than 1 px to the initial guess), fit position (omit events too close to the border and trim events where the illumination intensity is too uneven) and fit residuals (Supplementary Fig. 12).

Calculation of protein polarizability

The scattering cross-section of the AuNPs was calculated with the Mie formalism45 for a wavelength of 450 nm and a refractive index of nAu = 1.528 + 1.911i for gold46 and 1.337 for the embedding medium (H2O) (ref. 47). The linear scaling factor between the cubic root of the interferometric contrast c of the single particles and the sixth root of the scattering cross-section σscat was determined with an ordinary least squares48 σscat = (c × (28.1 ± 0.4) nm)2. By using the cubic root of the interferometric contrast, a normal distribution in particle diameter is assumed instead of a normal distribution in volume. With this relation, the scattering cross-section of the different protein oligomers (Fig. 5d) is estimated. From the Gaussian fits to the contrast distributions of the oligomers and their known masses m, the relationship c = m(6.82 ± 0.04) × 10−7 kDa–1 was determined with a least squares regression using the inverse of the fitted peak variance as respective weights. Combining these two relationships with the formula for Rayleigh scattering of a dielectric particle in equation (2) yields a specific polarizability of \(\frac{{\rm{\alpha }}}{{{m}}}\) = 239 ± 4 Å3 kDa–1.

Supplementary Data and references are available on the original website.

Resources
LabRulez
Logo of LinkedIn
 

Related content

Robust analysis of a variety of water and wastewater samples according to U.S. EPA Method 6020B (SW-846)

Applications
| 2023 | Thermo Fisher Scientific
Instrumentation
ICP/MS
Manufacturer
Thermo Fisher Scientific
Industries
Environmental

High-Throughput Analysis of Additive- Elements and Wear Metals in Lubricants by ICP-OES

Applications
| 2024 | Agilent Technologies
Instrumentation
ICP-OES
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Determination of Arsenic Species in Apple Juice by LC-ICP-MS Analysis

Applications
| 2024 | Shimadzu
Instrumentation
HPLC, Speciation analysis, ICP/MS
Manufacturer
Shimadzu
Industries
Food & Agriculture

Quantification of water in lactose with the OMNIS NIRS Analyzer

Applications
| 2024 | Metrohm
Instrumentation
NIR Spectroscopy
Manufacturer
Metrohm
Industries
Pharma & Biopharma

Triple Quadrupole ICP-MS or High Resolution ICP-MS? Which Instrument is Right for Me?

Technical notes
| 2017 | Thermo Fisher Scientific
Instrumentation
ICP/MS, ICP/MS/MS
Manufacturer
Thermo Fisher Scientific
Industries
Food & Agriculture
 

Related articles

Microplastics as particles are still an open topic, but the risks associated with their additives are known, says environmental toxicologist Ondřej Adamovský
Article | Plastics

Microplastics as particles are still an open topic, but the risks associated with their additives are known, says environmental toxicologist Ondřej Adamovský

But how do microplastics actually interact with the human body? What impact do they have on our environment and our health? Is it true that they penetrate places like the brain or placenta?
RECETOX - Centrum pro výzkum toxických látek v prostředí
tag
share
more
News from LabRulezICPMS Library - Week 39, 2024
Article | Application

News from LabRulezICPMS Library - Week 39, 2024

This week we bring to you applications by Agilent Technologies, Shimadzu, Thermo Fisher Scientific, and Metrohm!
LabRulez
tag
share
more
New tool provides researchers with improved understanding of stem cell aging in the brain
Article | Scientific article

New tool provides researchers with improved understanding of stem cell aging in the brain

The UW–Madison team combined autofluorescence — that natural light emission — and sequencing genetic material in single cells to study the behavior of neural stem cells.
University of Wisconsin-Madison
tag
share
more
Forever chemicals as a ticking time bomb for future generations?
Article | Interview

Forever chemicals as a ticking time bomb for future generations?

It is no exaggeration to say that all of us, including new-born, have these substances in our bodies. PFAS, known as forever chemicals, have many uses and are a part of every household.
RECETOX - Centrum pro výzkum toxických látek v prostředí
tag
share
more
 

Related content

Robust analysis of a variety of water and wastewater samples according to U.S. EPA Method 6020B (SW-846)

Applications
| 2023 | Thermo Fisher Scientific
Instrumentation
ICP/MS
Manufacturer
Thermo Fisher Scientific
Industries
Environmental

High-Throughput Analysis of Additive- Elements and Wear Metals in Lubricants by ICP-OES

Applications
| 2024 | Agilent Technologies
Instrumentation
ICP-OES
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Determination of Arsenic Species in Apple Juice by LC-ICP-MS Analysis

Applications
| 2024 | Shimadzu
Instrumentation
HPLC, Speciation analysis, ICP/MS
Manufacturer
Shimadzu
Industries
Food & Agriculture

Quantification of water in lactose with the OMNIS NIRS Analyzer

Applications
| 2024 | Metrohm
Instrumentation
NIR Spectroscopy
Manufacturer
Metrohm
Industries
Pharma & Biopharma

Triple Quadrupole ICP-MS or High Resolution ICP-MS? Which Instrument is Right for Me?

Technical notes
| 2017 | Thermo Fisher Scientific
Instrumentation
ICP/MS, ICP/MS/MS
Manufacturer
Thermo Fisher Scientific
Industries
Food & Agriculture
 

Related articles

Microplastics as particles are still an open topic, but the risks associated with their additives are known, says environmental toxicologist Ondřej Adamovský
Article | Plastics

Microplastics as particles are still an open topic, but the risks associated with their additives are known, says environmental toxicologist Ondřej Adamovský

But how do microplastics actually interact with the human body? What impact do they have on our environment and our health? Is it true that they penetrate places like the brain or placenta?
RECETOX - Centrum pro výzkum toxických látek v prostředí
tag
share
more
News from LabRulezICPMS Library - Week 39, 2024
Article | Application

News from LabRulezICPMS Library - Week 39, 2024

This week we bring to you applications by Agilent Technologies, Shimadzu, Thermo Fisher Scientific, and Metrohm!
LabRulez
tag
share
more
New tool provides researchers with improved understanding of stem cell aging in the brain
Article | Scientific article

New tool provides researchers with improved understanding of stem cell aging in the brain

The UW–Madison team combined autofluorescence — that natural light emission — and sequencing genetic material in single cells to study the behavior of neural stem cells.
University of Wisconsin-Madison
tag
share
more
Forever chemicals as a ticking time bomb for future generations?
Article | Interview

Forever chemicals as a ticking time bomb for future generations?

It is no exaggeration to say that all of us, including new-born, have these substances in our bodies. PFAS, known as forever chemicals, have many uses and are a part of every household.
RECETOX - Centrum pro výzkum toxických látek v prostředí
tag
share
more
 

Related content

Robust analysis of a variety of water and wastewater samples according to U.S. EPA Method 6020B (SW-846)

Applications
| 2023 | Thermo Fisher Scientific
Instrumentation
ICP/MS
Manufacturer
Thermo Fisher Scientific
Industries
Environmental

High-Throughput Analysis of Additive- Elements and Wear Metals in Lubricants by ICP-OES

Applications
| 2024 | Agilent Technologies
Instrumentation
ICP-OES
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Determination of Arsenic Species in Apple Juice by LC-ICP-MS Analysis

Applications
| 2024 | Shimadzu
Instrumentation
HPLC, Speciation analysis, ICP/MS
Manufacturer
Shimadzu
Industries
Food & Agriculture

Quantification of water in lactose with the OMNIS NIRS Analyzer

Applications
| 2024 | Metrohm
Instrumentation
NIR Spectroscopy
Manufacturer
Metrohm
Industries
Pharma & Biopharma

Triple Quadrupole ICP-MS or High Resolution ICP-MS? Which Instrument is Right for Me?

Technical notes
| 2017 | Thermo Fisher Scientific
Instrumentation
ICP/MS, ICP/MS/MS
Manufacturer
Thermo Fisher Scientific
Industries
Food & Agriculture
 

Related articles

Microplastics as particles are still an open topic, but the risks associated with their additives are known, says environmental toxicologist Ondřej Adamovský
Article | Plastics

Microplastics as particles are still an open topic, but the risks associated with their additives are known, says environmental toxicologist Ondřej Adamovský

But how do microplastics actually interact with the human body? What impact do they have on our environment and our health? Is it true that they penetrate places like the brain or placenta?
RECETOX - Centrum pro výzkum toxických látek v prostředí
tag
share
more
News from LabRulezICPMS Library - Week 39, 2024
Article | Application

News from LabRulezICPMS Library - Week 39, 2024

This week we bring to you applications by Agilent Technologies, Shimadzu, Thermo Fisher Scientific, and Metrohm!
LabRulez
tag
share
more
New tool provides researchers with improved understanding of stem cell aging in the brain
Article | Scientific article

New tool provides researchers with improved understanding of stem cell aging in the brain

The UW–Madison team combined autofluorescence — that natural light emission — and sequencing genetic material in single cells to study the behavior of neural stem cells.
University of Wisconsin-Madison
tag
share
more
Forever chemicals as a ticking time bomb for future generations?
Article | Interview

Forever chemicals as a ticking time bomb for future generations?

It is no exaggeration to say that all of us, including new-born, have these substances in our bodies. PFAS, known as forever chemicals, have many uses and are a part of every household.
RECETOX - Centrum pro výzkum toxických látek v prostředí
tag
share
more
 

Related content

Robust analysis of a variety of water and wastewater samples according to U.S. EPA Method 6020B (SW-846)

Applications
| 2023 | Thermo Fisher Scientific
Instrumentation
ICP/MS
Manufacturer
Thermo Fisher Scientific
Industries
Environmental

High-Throughput Analysis of Additive- Elements and Wear Metals in Lubricants by ICP-OES

Applications
| 2024 | Agilent Technologies
Instrumentation
ICP-OES
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Determination of Arsenic Species in Apple Juice by LC-ICP-MS Analysis

Applications
| 2024 | Shimadzu
Instrumentation
HPLC, Speciation analysis, ICP/MS
Manufacturer
Shimadzu
Industries
Food & Agriculture

Quantification of water in lactose with the OMNIS NIRS Analyzer

Applications
| 2024 | Metrohm
Instrumentation
NIR Spectroscopy
Manufacturer
Metrohm
Industries
Pharma & Biopharma

Triple Quadrupole ICP-MS or High Resolution ICP-MS? Which Instrument is Right for Me?

Technical notes
| 2017 | Thermo Fisher Scientific
Instrumentation
ICP/MS, ICP/MS/MS
Manufacturer
Thermo Fisher Scientific
Industries
Food & Agriculture
 

Related articles

Microplastics as particles are still an open topic, but the risks associated with their additives are known, says environmental toxicologist Ondřej Adamovský
Article | Plastics

Microplastics as particles are still an open topic, but the risks associated with their additives are known, says environmental toxicologist Ondřej Adamovský

But how do microplastics actually interact with the human body? What impact do they have on our environment and our health? Is it true that they penetrate places like the brain or placenta?
RECETOX - Centrum pro výzkum toxických látek v prostředí
tag
share
more
News from LabRulezICPMS Library - Week 39, 2024
Article | Application

News from LabRulezICPMS Library - Week 39, 2024

This week we bring to you applications by Agilent Technologies, Shimadzu, Thermo Fisher Scientific, and Metrohm!
LabRulez
tag
share
more
New tool provides researchers with improved understanding of stem cell aging in the brain
Article | Scientific article

New tool provides researchers with improved understanding of stem cell aging in the brain

The UW–Madison team combined autofluorescence — that natural light emission — and sequencing genetic material in single cells to study the behavior of neural stem cells.
University of Wisconsin-Madison
tag
share
more
Forever chemicals as a ticking time bomb for future generations?
Article | Interview

Forever chemicals as a ticking time bomb for future generations?

It is no exaggeration to say that all of us, including new-born, have these substances in our bodies. PFAS, known as forever chemicals, have many uses and are a part of every household.
RECETOX - Centrum pro výzkum toxických látek v prostředí
tag
share
more
Other projects
GCMS
LCMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike