The Easiest Smart Decision You Can Make The Agilent 9500 ICP-MS

Brochures and specifications | 2026 | Agilent TechnologiesInstrumentation
ICP/MS, ICP/MS/MS
Industries
Other
Manufacturer
Agilent Technologies

Summary

Significance of the topic


The reliable removal of spectral interferences is a central challenge in modern trace-element ICP-MS analysis. Laboratories face increasing demands to analyse complex matrices rapidly and with minimal rework, while meeting tighter detection limits and regulatory requirements. Making triple-quadrupole ICP-MS (ICP-QQQ) performance accessible, straightforward and safe for routine labs directly addresses productivity, data confidence, and scalability in environmental, food, materials and high-purity analyses.

Objectives and study overview


This document presents the Agilent 9500 ICP-QQQ design and performance features intended to simplify ICP-MS/MS operation for routine laboratories. Key goals summarized are: to deliver ICP-QQQ-level interference removal without complexity; to reduce analysis time and re-runs; to avoid additional reactive gas infrastructure by enabling ambient-air reactions; and to provide integrated automation and software tools that streamline method transfer, development, and diagnostics.

Methodology and Instrumentation


Approach and technical innovations described include:
  • Dual-Cell System (DCS): a next-generation dual ion-guide collision/reaction cell architecture that supports both collision-induced dissociation (CID) and kinetic energy discrimination (KED) across a wide mass range.
  • Advanced Helium Mode (AHM): a single, optimized helium collision mode combining CID and KED to replace multiple helium tuning variants and deliver improved sensitivity, particularly for low-mass analytes.
  • Air mode (ambient-air O2 mass-shift): using the oxygen component of ambient air to perform O2 mass-shift reactions, removing many on-mass interferences without requiring oxygen cylinders.
  • Full ICP-MS/MS workflow integration: instrument hardware features (easy-fit torch, auto-gas connections, UHMI aerosol dilution, integrated ISTD addition) combined with OpenLab ICP‑MS software (Method Advisor, batch conversion, guided diagnostics) and automation accessories (SPS autosamplers, AVS MS switching valve, ADS 2 autodilutor).

The brochure reports comparative performance testing (e.g., drinking water, seawater, and high-purity titanium matrix analyses) to demonstrate acquisition time savings, long-run stability, and background-equivalent concentrations (BECs) for difficult analytes.

Instrumentation Used


Primary instrument and key specifications described in the material:
  • Agilent 9500 Triple Quadrupole ICP-MS (ICP-QQQ) with unit mass full-size quadrupoles and optional extended mass range to 300 u.
  • Proprietary Dual-Cell System with Advanced Helium Mode and Air mode.
  • Dual-mode discrete dynode electron multiplier detector with automatic pulse-to-analog switching, dynamic range of ~11 orders of magnitude, minimum dwell times down to 0.05 ms (50 μs) for time-resolved analysis and ~100 μs for spectrum acquisition.
  • Easy-fit single-piece quartz torch with automatic gas connections and auto-alignment, cooled spray chamber with quick-release cover, and UHMI aerosol dilution.
  • Optional m-lens for reduced transition-metal background and improved long-run stability in high-matrix samples.
  • OpenLab ICP-MS software for method development, batch conversion, automated calibration and reporting; automation accessories: SPS 4/6 autosamplers, AVS switching valve, ADS 2 autodilutor.

Main results and discussion


Reported performance highlights and their analytical implications:
  • Interference removal: DCS enables robust CID and KED across masses and permits on-mass interferences to be resolved using O2 mass-shift with ambient air. This reduces reliance on multiple gas modes and separate oxygen supplies.
  • Sensitivity gains: Advanced Helium Mode provides an approximate 20× sensitivity improvement for low-mass elements (m/z < 23) relative to conventional helium mode, and roughly 2× improvement for mid-to-high masses in comparison to standard He mode.
  • Throughput improvement: Consolidation of multiple tune modes into AHM reduces method switching and stabilization delays, yielding >33% reduction in sample acquisition time in routine methods (example: drinking-water method acquisition time reduced from ~53 s to ~33 s).
  • Lower BECs for challenging analytes: Air mode produces low background-equivalent concentrations for elements such as P, S, As and Se that previously required dedicated O2 reaction gas; Air mode also suppresses doubly charged rare-earth interferences on As and Se by converting analytes to oxide ions (AsO+, SeO+), shifting them away from REE2+ overlaps.
  • High-matrix performance and stability: Using UHMI aerosol dilution, optimized rinse protocols and optional m-lens, the 9500 sustains long-run stability in high-salinity seawater and tolerates high-matrix titanium digests while achieving sub-ppt impurity detection and consistent internal standard recoveries over many injections.
  • Operational and safety benefits: Air mode removes the need for O2 cylinders and associated safety infrastructure; integrated air purifier and cell gas clean sensor stabilise performance and reduce maintenance surprises.

Benefits and practical applications


Practical advantages for laboratories include:
  • Reduced method complexity: single-mode AHM simplifies method setup and reduces dependence on specialist operators.
  • Higher throughput and lower cost-per-sample: elimination of gas-mode switches and faster acquisition lowers run times and sample turnaround.
  • Fewer re-runs and increased data confidence: improved interference removal reduces re-analysis and supports regulatory and QA/QC workflows.
  • Safer, lower-cost infrastructure: ambient-air reactions avoid reactive gas storage, regulators and associated facility changes.
  • Broad applicability: suitable for environmental monitoring (water, seawater), food and soil analyses, semiconductor and high-purity materials testing (ppt-level impurity analysis), and radionuclide/actinide work when extended mass ranges and reaction chemistries are employed.

Future trends and opportunities


Key directions and opportunities suggested by the technology described:
  • Wider adoption of ICP-MS/MS in routine labs as ease-of-use and automation lower the barrier to entry, enabling more sectors to benefit from interference-free quantitation.
  • Further development of integrated software tools and AI-guided diagnostics to accelerate method transfer, real-time troubleshooting and predictive maintenance.
  • Expanded reaction-chemistry workflows leveraging ambient gases and advanced cell control to resolve increasingly complex interferences without additional consumable gases.
  • Greater focus on long-term robustness for high-matrix and production environments (enhanced lens designs, interface materials, and automated cleaning routines).
  • Integration with laboratory automation and sample-prep robotics to minimize manual dilution, reduce consumable waste and further improve throughput and reproducibility.

Conclusion


The Agilent 9500 ICP-QQQ combines a next-generation Dual-Cell System, Advanced Helium Mode and an ambient-air reaction capability to deliver ICP-MS/MS-level interference removal with reduced operational complexity. Reported gains include substantial sensitivity improvements for low-mass elements, >33% reductions in acquisition time through single-mode operation, and practical benefits such as avoidance of reactive gas cylinders and improved long-run stability in high-matrix samples. Coupled with integrated software (OpenLab ICP‑MS) and automation options, the platform targets routine laboratories seeking ICP-QQQ performance without specialist overhead, improving confidence, throughput and safety.

References


Agilent Technologies. Agilent 9500 ICP-QQQ Product Brochure. Published June 2026.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
The Agilent 9500 ICP-MS
The Agilent 9500 ICP-MS
2026|Agilent Technologies|Brochures and specifications
The Easiest Smart Decision You Can Make The Agilent 9500 ICP-MS Introduction | 9500 | Design | DCS | Performance | OpenLab | Automation Are Interferences Impacting Your Trace Element Analysis? Do you face growing pressure to deliver faster, interference-free…
Key words
ahm, ahmicp, icpair, airmode, modeadvanced, advancedhelium, heliumview, viewsingle, singlebec, becyour, yourcell, celldcs, dcsinterference, interferencedual, dualeffortless
Air Cell Mode of the Agilent 9500 ICP-QQQ with Dual-Cell System
Technical Overview Agilent 9500 ICP-MS Air Cell Mode of the Agilent 9500 ICP-QQQ with Dual-Cell System Simple and effective interference reduction using ambient air Introduction to the Air cell Interference reduction technology in single quadrupole and triple quadrupole ICP-MS instruments…
Key words
cell, cellinterferences, interferencesair, airinterference, interferenceahm, ahmdoubly, doublymode, modereduction, reductioncharged, chargedicp, icpreducing, reducingreaction, reactionbecs, becsgadolinium, gadoliniumsuppressing
Automated Analysis of Foods by ICP-QQQ with Discrete Sampling and Autodilution
Application Note Foods Automated Analysis of Foods by ICP-QQQ with Discrete Sampling and Autodilution Fast, accurate AOAC compliant food analysis using the Agilent 9500 ICP-QQQ with AVS MS and ADS 2 Author Santhosh Siva Agilent Technologies, Inc. Introduction Manufacturers and…
Key words
ahm, ahmair, aircell, cellicp, icpmode, modedoubly, doublyfood, fooddilution, dilutionvalue, valueqqq, qqqinterference, interferenceagilent, agilentdcs, dcselement, elementmeasured
Agilent 9500 ICP‑QQQ with m‑Lens for Ultratrace Analysis of High‑Purity Reagents
Application Note Semiconductors Agilent 9500 ICP‑QQQ with m‑Lens for Ultratrace Analysis of High‑Purity Reagents Achieving low backgrounds under hot plasma conditions using ICP-QQQ preset methods Author Rentaro Yamashita Agilent Technologies, Inc. Introduction Controlling trace-metal contaminants is essential in both semiconductor…
Key words
ahm, ahmultratrace, ultratraceppt, pptgas, gaslens, lensautotuned, autotunedelements, elementsomega, omegabec, becmin, minpreset, presetdls, dlsplatinum, platinumpurity, purityqqq
Other projects
GCMS
LCMS
Follow us
FacebookLinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike