Investigation of Ni on Si thin film with ARL EQUINOX 100 X-ray Diffractometer
Applications | 2023 | Thermo Fisher ScientificInstrumentation
X-ray, XRD
IndustriesMaterials Testing
ManufacturerThermo Fisher Scientific
Summary
Význam tématu
Thin film and coating characterization by XRD and XRR is essential for developing functional materials in photovoltaics, optoelectronics and advanced optical systems. Structural parameters and layer thickness of nanometer-scale films directly influence device performance, making rapid and reliable analysis crucial for research, quality control and industrial applications.Cíle a přehled studie / článku
This application note presents the use of the Thermo Scientific ARL EQUINOX 100 benchtop diffractometer to analyze a Ni layer on a Si substrate. The objectives are to demonstrate fast GIXRD phase identification and precise XRR thickness measurement, highlighting instrument capabilities for routine thin film investigation.Použitá metodika a instrumentace
Grazing incidence X-ray diffraction (GIXRD) was performed at a fixed incident angle of 0.5° to isolate the Ni layer signal. X-ray reflectometry (XRR) measured film thickness and roughness based on interference fringes between reflected beams. The ARL EQUINOX 100 employs a high-brilliance Cu micro-focus tube (50 W) with mirror optics and a curved position sensitive detector (CPS) for simultaneous peak collection. Thin film attachment provides computer-controlled ω and z alignment. Data processing and analysis used SYMPHONIX for primary reduction, MATCH! with the COD database for phase identification, and MAUD for XRR refinement.Hlavní výsledky a diskuse
- GIXRD identified the Ni face-centered cubic structure (space group Fm3m, a = 3.5238 Å) within 1 minute of acquisition.
- XRR refinement yielded a Ni layer thickness of 320.7 ± 1.1 Å and roughness of 3.78 ± 0.32 Å, showing a 5 % deviation from the nominal 306.9 Å value.
Přínosy a praktické využití metody
- Measurement speed: full GIXRD scan in 1 min enables high-throughput screening.
- Ease of use: straightforward sample alignment without advanced operator skills.
- Portability: benchtop design allows flexible lab placement or field use without special infrastructure.
- Combined analysis: simultaneous structural and thickness evaluation supports QC/QA workflows in industrial and academic environments.
Budoucí trendy a možnosti využití
Advancements may include in situ monitoring of film growth, temperature-dependent structural studies, multilayer and hybrid material analysis, and integration with automated process control. Enhanced detector sensitivity and software automation will further shorten analysis times and improve precision.Závěr
The ARL EQUINOX 100 paired with the thin film attachment offers a versatile, user-friendly platform for fast and accurate GIXRD and XRR characterization of thin films. Its benchtop format, rapid data acquisition and reliable analysis make it suitable for both routine QC/QA and advanced research in analytical chemistry.Použitá instrumentace
- Thermo Scientific ARL EQUINOX 100 benchtop diffractometer
- Cu micro-focus X-ray tube (50 W) with mirror optics
- Curved position sensitive detector (CPS)
- Computer-controlled ω and z thin film attachment
- Software: SYMPHONIX, MATCH! (with COD database), MAUD
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Investigation of a CIGS solar cell with ARL EQUINOX 100 X-ray Diffractometer and ARL QUANT'X EDXRF Spectrometer
2020|Thermo Fisher Scientific|Applications
Investigation of a CIGS solar cell with ARL EQUINOX 100 X-ray Diffractometer and ARL QUANT'X EDXRF Spectrometer Authors: Dr. Simon Welzmiller, Ju Weicai, XRD Application Specialists Introduction Copper indium gallium selenide (CIGS) is one of three predominantly used materials for…
Key words
cigs, cigssolar, solaredxrf, edxrfarl, arlthin, thingixrd, gixrdfilm, filmquant’x, quant’xxrd, xrdcells, cellslayer, layercrystalline, crystallineperipheral, peripherallayers, layersinvestigations
Thermo Scientific ARL EQUINOX 100 X-ray Diffractometers
2023|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific ARL EQUINOX 100 X-ray Diffractometers Compact Flexible Applications Attachments Performance Portfolio Compact XRD solution High performance in a compact size The Thermo Scientific™ ARL™ EQUINOX 100 X-ray • Standard power supply; no external water cooling needed • Reliable…
Key words
reflection, reflectionstage, stagespinning, spinningattachments, attachmentsxrd, xrdrotation, rotationcompact, compactsample, sampleportfolio, portfoliotransmission, transmissionflexible, flexiblecontinuous, continuousapplications, applicationsthin, thinmode
XRD investigation of three types of polyethylene films with ARL EQUINOX 100 X-ray Diffractometer
2019|Thermo Fisher Scientific|Applications
XRD investigation of three types of polyethylene films with ARL EQUINOX 100 X-ray Diffractometer Author: Gregory Schmidt, XRD Applications Scientist Introduction Polyethylene (PE) is the most common plastic in use today. In 2017 alone, over 100 million tons of PE…
Key words
goof, goofxrd, xrdcrystalline, crystallinecrystallite, crystallitefilms, filmsamorphous, amorphousldpe, ldpehdpe, hdpelldpe, lldpedensity, densityrietveld, rietvelddiffractometer, diffractometercrystallinity, crystallinityintermolecular, intermolecularpolyethylene
XRD Investigation of Ibuprofen with ARL EQUINOX 100 in Transmission Mode
2017|Thermo Fisher Scientific|Applications
APPLICATION NOTE Introduction X-ray diffraction is a standard technique to investigate pharmaceutical compounds and formulations, both in production and academic research. As the need for new drugs to better serve society increases, so does the demand for versatile X-Ray diffractometers…
Key words
diffraction, diffractionvendors, vendorsdifferent, differentdiffractometers, diffractometersray, raypharmaceutical, pharmaceuticaltransmission, transmissioncrystalline, crystallineibuprofen, ibuprofenwhereof, whereofrealms, realmscompounds, compoundspowder, powderequinox, equinoxtalc