How flexible is FlashSmart Elemental Analyzer to meet your growing analytical needs?
Brochures and specifications | 2024 | Thermo Fisher ScientificInstrumentation
The determination of carbon, hydrogen, nitrogen, sulfur and oxygen in diverse matrices is fundamental for quality control, regulatory compliance and research in chemistry, materials, environmental and food industries. Rapid, reliable and automated workflows for multi-element analysis support high throughput laboratories and ensure consistent data reporting.
This application note introduces the Thermo Scientific™ FlashSmart™ Elemental Analyzer (EA) as a flexible platform to address evolving analytical demands. The note outlines system capabilities, dual-furnace configuration, automation features and software support that enable quantitative elemental assays from one to five elements across micro and macro modes.
The FlashSmart EA applies a modified Dumas combustion method. Samples are oxidized in a high-temperature reactor, gases pass through reduction and absorption stages, and individual element concentrations are measured by thermal conductivity detection. Dual independent analytical circuits allow sequential or parallel operation.
By integrating two separate analytical channels, sample throughput increases significantly and downtime is minimized. Automated switching between CHNS and oxygen analysis reduces manual intervention. The MVC module’s gas routing capability lowers helium consumption by transitioning to nitrogen or argon during standby. Software templates simplify method setup and deliver reproducible reports.
Advances in elemental analyzers will likely focus on further integration with laboratory information management systems (LIMS), more sophisticated AI-driven data processing and expanded method libraries for emerging analytes. Continued development of greener carrier gas alternatives and enhanced autosampler designs will reinforce sustainability and efficiency in routine elemental analysis.
The FlashSmart EA delivers a unified solution for quantitative multi-element determination with unparalleled flexibility, automation and data handling. Dual furnaces, modular autosamplers and intuitive software combine to meet current analytical needs and accommodate future laboratory growth.
No external literature references were provided in the source document.
Elemental Analysis
IndustriesManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
The determination of carbon, hydrogen, nitrogen, sulfur and oxygen in diverse matrices is fundamental for quality control, regulatory compliance and research in chemistry, materials, environmental and food industries. Rapid, reliable and automated workflows for multi-element analysis support high throughput laboratories and ensure consistent data reporting.
Objectives and Study Overview
This application note introduces the Thermo Scientific™ FlashSmart™ Elemental Analyzer (EA) as a flexible platform to address evolving analytical demands. The note outlines system capabilities, dual-furnace configuration, automation features and software support that enable quantitative elemental assays from one to five elements across micro and macro modes.
Used Methodology
The FlashSmart EA applies a modified Dumas combustion method. Samples are oxidized in a high-temperature reactor, gases pass through reduction and absorption stages, and individual element concentrations are measured by thermal conductivity detection. Dual independent analytical circuits allow sequential or parallel operation.
Used Instrumentation
- FlashSmart Elemental Analyzer with dual furnaces
- Thermo Scientific™ MultiValve Control (MVC) Module for channel switching and autosampler control
- EagerSmart™ Data Handling Software for method templates, data acquisition and automated calculations (heat values, CO₂ emissions, protein content, empirical formula)
Main Results and Discussion
By integrating two separate analytical channels, sample throughput increases significantly and downtime is minimized. Automated switching between CHNS and oxygen analysis reduces manual intervention. The MVC module’s gas routing capability lowers helium consumption by transitioning to nitrogen or argon during standby. Software templates simplify method setup and deliver reproducible reports.
Benefits and Practical Applications
- High throughput analysis for QC and R&D in organic chemistry, petrochemistry, food/feed, cosmetics, agronomy and marine science
- Flexible configuration: over 20 element combinations in one system
- Cost reduction via extended consumable life and optimized gas usage
- Automated sample introduction for solids and liquids
- Comprehensive reporting with built-in calculations for environmental and nutritional parameters
Future Trends and Opportunities
Advances in elemental analyzers will likely focus on further integration with laboratory information management systems (LIMS), more sophisticated AI-driven data processing and expanded method libraries for emerging analytes. Continued development of greener carrier gas alternatives and enhanced autosampler designs will reinforce sustainability and efficiency in routine elemental analysis.
Conclusion
The FlashSmart EA delivers a unified solution for quantitative multi-element determination with unparalleled flexibility, automation and data handling. Dual furnaces, modular autosamplers and intuitive software combine to meet current analytical needs and accommodate future laboratory growth.
References
No external literature references were provided in the source document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Thermo Scientific FlashSmart Elemental Analyzer
2024|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific FlashSmart Elemental Analyzer A single CHNS/O, NC, N/Protein Analyzer handling all applications Superior elemental analysis that grows with your needs Lead the way in elemental analysis with a single instrument handling all applications. You and your team can…
Key words
flashsmart, flashsmartchns, chnsmvc, mvcncs, ncsanalyzer, analyzermultivalve, multivalvechn, chnamerican, americansoftware, softwareautomated, automatedauto, autooxytune, oxytuneconfiguration, configurationsoils, soilsfibers
Optimized Helium Consumption in the Thermo Scientific FlashSmart Elemental Analyzer
2016|Thermo Fisher Scientific|Applications
TECHNICAL NOTE Dr. Liliana Krotz, Dr. Francesco Leone and Dr. Guido Giazzi Thermo Fisher Scientific, Milan, Italy Key Words Argon, Carrier Gas, Consumption, Cost per Analysis, Elemental Analysis, Helium, Nitrogen, MVC Module Goal To illustrate different options for the reduction…
Key words
flashsmart, flashsmarteagersmart, eagersmarthelium, heliumstand, standmvc, mvcargon, argonnitrogen, nitrogenconsumption, consumptiongas, gascarrier, carrierfurnace, furnacetemperatures, temperatureselectrovalves, electrovalvesanalyzer, analyzermodule
Elemental Analysis: Fully automated double channel analysis for CHNS determination by TCD Detector and trace sulfur by FPD Detector
2017|Thermo Fisher Scientific|Applications
S S TECHNICAL NOTE 42286 S Elemental Analysis: Fully automated double channel analysis for CHNS determination by TCD Detector and trace sulfur by FPD Detector Authors Dr. Liliana Krotz, Dr. Francesco Leone, and Dr. Guido Giazzi Thermo Fisher Scientific, Milan,…
Key words
chns, chnsreactor, reactorsulfur, sulfurtcd, tcdrsd, rsdwepal, wepalfpd, fpddetector, detectorflashsmart, flashsmartcatalyst, catalystsoil, soilcombustion, combustionleft, leftbbot, bbotanalyzed
High Productivity of Thermo Scientific FlashSmart CHNS/CHNS Analyzer through the MultiValve Control (MVC) Module
2016|Thermo Fisher Scientific|Applications
TECHNICAL NOTE Dr. Liliana Krotz, Dr. Francesco Leone and Dr. Guido Giazzi Thermo Fisher Scientific, Milan, Italy Key Words Accuracy, Automation, CHNS, Flash Combustion, Organic Chemistry, Productivity, Unattended Analysis Goal To demonstrate the performance of the the FlashSmart Elemental Analyzer…
Key words
sulfanilamide, sulfanilamidemethionine, methioninechns, chnsmvc, mvcunk, unkmultivalve, multivalveeagersmart, eagersmartreactor, reactorflashsmart, flashsmartstd, stdhelium, heliumcombustion, combustionmonth, monthleft, leftrsd