1013 Ω amplifier technology: How low can you go?
Technical notes | 2017 | Thermo Fisher ScientificInstrumentation
Accurate measurement of low intensity ion beams underpins critical applications in isotope geochemistry and nuclear safeguards by enabling precise determination of minor isotopes in limited sample sizes.
The research investigates the performance of Thermo Scientific’s 1013 Ω amplifier technology combined with a 3.3 pA current calibration board in static multicollection Faraday measurements, aiming to extend low noise and high stability into the ion counting regime and compare it with traditional ion counters and 1011 Ω amplifiers.
Static multicollection measurements were performed with Thermo Scientific Triton Plus TIMS and optionally Neptune Plus MC-ICP-MS systems equipped with 1010 Ω, 1011 Ω, 1012 Ω and 1013 Ω amplifiers. An integrated 3.3 pA calibration board applies defined currents to automate gain and baseline calibration. Baseline noise and gain stability were assessed over integration times from 30 to 500 seconds, and Nd isotope ratios were measured at varying signal intensities.
Integration of high-ohmic amplifiers and automated calibration is expected to extend to other MC-ICP-MS platforms and emerging isotope systems. Future development may include real-time baseline correction, portable instrumentation for fieldwork, and advanced data processing to exploit the expanded dynamic range.
Thermo Scientific’s 1013 Ω amplifier technology, coupled with a 3.3 pA calibration board, bridges the gap between ion counting and Faraday detection, delivering unprecedented dynamic range, low noise and stable gain for precise isotope ratio measurements on low intensity beams. This advancement streamlines workflows, reduces sample requirements and opens new possibilities in isotope analysis.
ICP/MS
IndustriesManufacturerThermo Fisher Scientific
Summary
Význam tématu
Accurate measurement of low intensity ion beams underpins critical applications in isotope geochemistry and nuclear safeguards by enabling precise determination of minor isotopes in limited sample sizes.
Cíle a přehled studie
The research investigates the performance of Thermo Scientific’s 1013 Ω amplifier technology combined with a 3.3 pA current calibration board in static multicollection Faraday measurements, aiming to extend low noise and high stability into the ion counting regime and compare it with traditional ion counters and 1011 Ω amplifiers.
Použitá metodika a instrumentace
Static multicollection measurements were performed with Thermo Scientific Triton Plus TIMS and optionally Neptune Plus MC-ICP-MS systems equipped with 1010 Ω, 1011 Ω, 1012 Ω and 1013 Ω amplifiers. An integrated 3.3 pA calibration board applies defined currents to automate gain and baseline calibration. Baseline noise and gain stability were assessed over integration times from 30 to 500 seconds, and Nd isotope ratios were measured at varying signal intensities.
Hlavní výsledky a diskuse
- Dynamic range of 1013 Ω amplifiers exceeds 30 Mcps, an order of magnitude above ion counters.
- Baseline noise better than 0.7 μV over 24 h, with 0.43 μV long-term stability (2 SD) and inter-channel gain stability better than 15 ppm (2 SD).
- Baseline uncertainty falls to ±0.54 μV (2 SD) at 500 s integration, corresponding to 0.1 ‰ uncertainty on a 5 mV signal.
- Signal-to-noise ratios improved from ~3500 for 1011 Ω to ~28000 for 1013 Ω amplifiers, matching theoretical Johnson–Nyquist predictions.
- Nd isotope measurements demonstrate 143Nd/144Nd precision of 0.35 ‰ (2 RSD) at 1 mV (~63 kcps) and <34 ppm at ≥40 mV using 1013 Ω amplifiers.
Přínosy a praktické využití metody
- Eliminates ion counter dead-time and yield uncertainties by enabling high dynamic range static multicollection.
- Reduces calibration frequency to weekly due to superior gain stability.
- Enhances precision and accuracy for low-signal isotope systems in geochemistry, nuclear analysis and small-sample studies.
- Supports automated software calibration for streamlined laboratory workflows.
Budoucí trendy a možnosti využití
Integration of high-ohmic amplifiers and automated calibration is expected to extend to other MC-ICP-MS platforms and emerging isotope systems. Future development may include real-time baseline correction, portable instrumentation for fieldwork, and advanced data processing to exploit the expanded dynamic range.
Závěr
Thermo Scientific’s 1013 Ω amplifier technology, coupled with a 3.3 pA calibration board, bridges the gap between ion counting and Faraday detection, delivering unprecedented dynamic range, low noise and stable gain for precise isotope ratio measurements on low intensity beams. This advancement streamlines workflows, reduces sample requirements and opens new possibilities in isotope analysis.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Expanding the analytical range utilizing 1013 Ω amplifier technology: Measurement of 100 pg Nd samples
2018|Thermo Fisher Scientific|Applications
TECHNICAL NOTE 30493 Expanding the analytical range utilizing 1013 Ω amplifier technology: Measurement of 100 pg Nd samples Authors Hauke Vollstaedt, Grant Craig, Nicholas Lloyd, and Johannes Schwieters Thermo Fisher Scientific, Bremen, Germany Keywords 1013 Ω amplifier technology, isotope ratio,…
Key words
filament, filamentisotope, isotopemeasurements, measurementsfractionation, fractionationoutgassed, outgassedprecision, precisioncup, cupsignal, signalfaraday, faradaytriton, tritonmeasurement, measurementdiscard, discardratios, ratioscounting, countingfactors
New Design 1013 Ω Amplifiers for Measurement of Small Ion Beam Currents
2015|Thermo Fisher Scientific|Applications
C. Bouman, A. Trinquier, N. Lloyd, J. Schwieters, Thermo Fisher Scientific, Bremen, Germany; Janne Koornneef, and Gareth Davies, VU University, Amsterdam, Netherlands Ap plica t ion Note 3 0 28 2 New Design 1013 Ω Amplifiers for Measurement of Small…
Key words
faraday, faradayamplifiers, amplifierstims, timsbeam, beamhorizontal, horizontalcup, cuptriton, tritonmulticollector, multicollectorcurrents, currentsamplifier, amplifierion, ioncounting, countingsem, semlimit, limitsignal
Dynamic time correction for high precisionisotope ratio measurements
2019|Thermo Fisher Scientific|Technical notes
TECHNICAL NOTE 30396 Dynamic time correction for high precisionisotope ratio measurements Thermo Scientific Neptune XT MC-ICP-MS with 1013 Ω Amplifier Technology Authors Abstract Grant Craig1, Zhifang Hu2, Anyu Zhang2, Nicholas S. Lloyd1, Claudia Bouman1 and Johannes Schwieters1 1 Thermo Fisher…
Key words
δie, δiefaraday, faradayisotope, isotoperse, rsetau, tauamplifiers, amplifierscup, cupexponential, exponentialcorrection, correctionspot, spotratio, ratioamplifier, amplifierexternal, externalsignal, signalmean
TIMS: Long Term Reproducibility of Nd Isotopic Data Acquired on TRITON Plus
2014|Thermo Fisher Scientific|Applications
Anne Trinquier, Thermo Fisher Scientific, Bremen, Germany Ap plica t ion Note 3 0 28 0 TIMS: Long Term Reproducibility of Nd Isotopic Data Acquired on TRITON Plus Key Words Neodymium, TRITON Plus TIMS, Static Mode, Virtual Amplifier, 1011Ω Amplifier…
Key words
amplifier, amplifiercup, cupisotopic, isotopicvirtual, virtualfilament, filamenttriton, tritonneodymium, neodymiumtims, timsdouble, doubleuncertainty, uncertaintyoutgasing, outgasingpeakcenter, peakcenteranalyses, analysesreproducibility, reproducibilitystatic