Robust analysis of a variety of water and wastewater samples according to U.S. EPA Method 6020B (SW-846)

Applications | 2023 | Thermo Fisher ScientificInstrumentation
ICP/MS
Industries
Environmental
Manufacturer
Thermo Fisher Scientific

Summary

Significance of the Topic


Environmental monitoring of water and wastewater is critical to protect ecosystems and human health. U.S. EPA Method 6020B defines robust procedures for trace and major element analysis by ICP-MS, addressing increasing waste loads from industrialization, population growth, and climate impacts. Reliable, high-throughput measurement of complex matrices ensures regulatory compliance and informs remediation strategies.

Objectives and Study Overview


This application note evaluates the Thermo Scientific iCAP RQplus ICP-MS coupled with Qtegra ISDS Software for:
  • Performing direct analysis of water and wastewater samples across a wide concentration range.
  • Meeting all performance criteria of EPA Method 6020B over a three-day sequence (600 samples).
  • Demonstrating instrument robustness, accuracy, and precision without maintenance downtime.

Methodology


Samples and standards were prepared according to EPA guidelines, including calibration blanks, initial/continuing calibration verification (ICV/CCV), interference check solutions (ICSA/ICSAB), and matrix spikes/duplicates. Key aspects:
  • Multi-element calibration with eight standards covering trace to major levels.
  • Online addition of internal standards (Li, Sc, Y, Rh, In, Tb, Ho, Bi).
  • Kinetic Energy Discrimination (KED) mode with helium collision gas to remove polyatomic interferences.
  • Automated QC checks in Qtegra ISDS Software to flag any deviations in real time.

Instrumentation


The iCAP RQplus ICP-MS was configured with:
  • MicroMist nebulizer and cyclonic quartz spray chamber (400 µL/min).
  • Quartz injector (2.5 mm i.d.) and torch.
  • Ni-tipped sample/skimmer cones and high-matrix skimmer insert.
  • Argon Gas Dilution (AGD) system for direct handling of high TDS samples.
  • RF power 1,550 W, auxiliary gas 0.8 L/min, cool gas 14 L/min.

Results and Discussion


Detection limits (IDLs) met or exceeded EPA targets for 24 analytes, with R2 > 0.9995. Lower limits of quantification (LLOQs) were established for all elements. Linear ranges extended up to 1,000 mg/L for major elements, reducing the need for sample re-dilution. QC checks showed:
  • ICB and CCB blanks below half LLOQ, confirming minimal carry-over.
  • ICV and CCV recoveries between 90–110% over three days.
  • Interference checks (ICSA/ICSAB) recoveries 90–110%, validating KED mode effectiveness.
  • Matrix spikes and duplicates met ±25% recovery and <20% RSD criteria, even in high‐TDS samples.
  • Internal standard responses remained within 75–125% across a 10-hour run, illustrating robustness without maintenance.

Benefits and Practical Applications


This workflow delivers:
  • High sample throughput with up to 200 analyses per day without maintenance interruptions.
  • Accurate multi‐element data for trace and major constituents in complex matrices.
  • Automated compliance with EPA Method 6020B via built-in QC functions in Qtegra ISDS Software.
  • Reduced sample preparation and re-analysis through wide linear ranges and AGD system.

Future Trends and Opportunities


Advances in ICP-MS will focus on:
  • Further automation and remote operation for 24/7 monitoring.
  • Integration of real-time data analytics and predictive maintenance.
  • Enhanced interference removal via novel collision/reaction cell chemistries.
  • Miniaturized and field-deployable platforms for on-site environmental assessments.

Conclusion


The Thermo Scientific iCAP RQplus ICP-MS with Argon Gas Dilution and Qtegra ISDS Software reliably meets EPA Method 6020B requirements for water and wastewater analysis. It achieves excellent detection limits, stability, and throughput over extended runs with minimal maintenance. This solution enhances laboratory productivity and data integrity for environmental compliance.

References


  • EPA Method 6020B, Office of Solid Waste and Emergency Response, U.S. Environmental Protection Agency.
  • Thermo Fisher Scientific iCAP RQplus ICP-MS Product Manual.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Robust analysis of a variety of water, wastewater, and soil samples according to U.S. EPA Method 6020B (SW-846)
Application note | 002881 Environmental Robust analysis of a variety of water, wastewater, and soil samples according to U.S. EPA Method 6020B (SW-846) Authors Goal Bhagyesh Surekar, Daniel Kutscher To evaluate and demonstrate performance of the Thermo Scientific™ iCAP™ MSX…
Key words
icsab, icsabicv, icvicsa, icsaccv, ccvanalytes, analyteswere, wereicb, icbpercent, percentmsx, msxicap, icapcalibration, calibrationstandards, standardssolutions, solutionsconcentrations, concentrationscontinuing
Accurate and robust analysis of challenging environmental samples for regulatory compliance
Application note | 001835 Environmental Accurate and robust analysis of challenging environmental samples for regulatory compliance Authors Goal Bhagyesh Surekar1, John Schmelzel2, To highlight how most complex environmental samples, including soil digests and different Daniel Kutscher water samples, can be…
Key words
analytes, analytesrqplus, rqplusdigestion, digestionisds, isdsanalysis, analysisicap, icapl·min, l·mincontract, contractsamples, samplesanalytical, analyticalaccuracy, accuracyicb, icbduring, duringenvironmental, environmentalchecks
A Complete Method for Environmental Samples by Simultaneous Axially Viewed ICP- OES following US EPA Guidelines
A Complete Method for Environmental Samples by Simultaneous Axially Viewed ICPOES following US EPA Guidelines Application Note Inductively Coupled Plasma-Optical Emission Spectrometers Authors Introduction Scott Bridger With the growing demand for elemental analysis of environmental samples and the financial pressures…
Key words
linear, linearccv, ccvcrdl, crdlblank, blankvista, vistaccb, ccbicsa, icsaicsab, icsabcalibration, calibrationcri, criicv, icvidl, idlsdg, sdgepa, epaprotocols
Analysis of Environmental Samples with the Agilent 730-ES Following US EPA Guidelines
Analysis of Environmental Samples with the Agilent 730-ES Following US EPA Guidelines Application Note Inductively Coupled Plasma-Optical Emission Spectrometers Author Introduction Vincent Calderon The United States Environmental Protection Agency (EPA) Contract Laboratory Program (CLP) defines the analytical methods accepted for…
Key words
crql, crqlpass, passlinear, linearcri, criconc, concicsab, icsabelement, elementlcs, lcsspike, spikemeasured, measuredicv, icvsample, samplemdl, mdlicsa, icsacalibration
Other projects
GCMS
LCMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike