TRM - Ce, Co, Li, Mg, Tl, Y - Aqueous calibration solution ASTASOL® TUNE25

Others | 2023 | ANALYTIKAInstrumentation
Standards and chemicals
Industries
Manufacturer
ANALYTIKA

Summary

Significance of the Topic


Aqueous calibration solutions are fundamental tools for ensuring accuracy and traceability in quantitative analysis across various spectrometric and electroanalytical techniques. ASTASOL® TUNE25 provides a multi-element standard with precisely known concentrations of Ce, Co, Li, Mg, Tl and Y, enabling laboratories to achieve reliable calibration and maintain consistent quality control.

Objectives and Study Overview


This document describes the preparation, characterization and intended application of ASTASOL® TUNE25, a certified reference material (CRM) designed to support calibration in atomic absorption spectrometry (AAS), atomic emission spectrometry (AES), inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), molecular absorption spectrometry and select electroanalytical methods. The key objectives are to assign accurate concentration values with defined uncertainties and to demonstrate homogeneity and stability over the product’s shelf life.

Methodology and Used Instrumentation


The solution is prepared gravimetrically using high-purity primary compounds (purities ≥99.98%) dissolved in 2% v/v sub-boiled HNO₃ and ultrapure water (resistivity ≥18 MΩ·cm). Traceability is established through comparison and calibration against NIST-traceable CRMs (AN 9011, AN 9012, AN 9030, AN 9032, AN 9062, AN 9067) using techniques such as AAS, AES and ICP-OES.

Main Results and Discussion


  • Assigned concentration for each element (Ce, Co, Li, Mg, Tl, Y): 1.00 ± 0.01 µg/L at 20 °C (k=2).
  • Total trace impurities in the final solution are below 0.005 µg/L.
  • Homogeneity studies confirm uniform distribution of analytes across bottles.
  • Stability testing over the 12-month shelf life shows no significant drift when stored between 5–30 °C and maintained at 20 ± 0.5 °C before use.

Benefits and Practical Applications


ASTASOL® TUNE25 enables precise multi-element calibration, reducing the need for single-element standards. Its certified values and uncertainty support rigorous quality assurance and compliance with ISO and GLP requirements. The formulation in 2% HNO₃ matrix facilitates direct use in common spectrometric workflows without additional acidification steps.

Future Trends and Potential Applications


  • Expansion of multi-element CRMs to include emerging trace analytes relevant to environmental and biomedical analyses.
  • Development of digital certification and blockchain-based traceability records to streamline regulatory compliance.
  • Integration of CRMs with automated calibration systems and laboratory information management systems (LIMS) for real-time data validation.

Conclusion


ASTASOL® TUNE25 offers a reliable, high-purity multi-element calibration solution with well-defined metrological traceability. Its robust characterization, combined with demonstrated homogeneity and stability, makes it an essential tool for quantitative analysis in diverse spectrometric and electroanalytical methods.

Used Instrumentation


  • Gravimetric balances for precise weighing of primary compounds.
  • Sub-boiled HNO₃ purification system (ANALPURE®).
  • Ultrapure water system (≥18 MΩ·cm, 0.22 µm filtration).
  • Atomic absorption spectrometers (AAS).
  • Atomic emission spectrometers (AES).
  • Inductively coupled plasma optical emission spectrometers (ICP-OES).

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
TRM - Ba, Be, Bi, Ce, Co, In, Li, Ni, Pb, U - Aqueous calibration solution ASTASOL® TUNE01
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net IDENTIFICATION SHEET Aqueous calibration solution ASTASOL® ASTASOL® TUNE01 This Identification sheet is designed in accordance with ISO Guide 31 Category: Traced reference materials Analytes: Ba, Be,…
Key words
parafilm, parafilmprofessionally, professionallytraced, tracedaqueous, aqueousneck, neckgravimetric, gravimetriccalibrator, calibratoruncertainty, uncertaintyreference, referencematerials, materialsastasol, astasoldeclared, declaredexpiration, expirationopening, openinganalysing
TRM - Al, Ba, Ca, Cu, K, Mg, Mn, Ni, P, Zn - Aqueous calibration solution ASTASOL® TUNE12
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net IDENTIFICATION SHEET Aqueous calibration solution ASTASOL® ASTASOL® TUNE12 This Identification sheet is designed in accordance with ISO Guide 31 Category: Traced reference materials Analytes: Al, Ba,…
Key words
parafilm, parafilmprofessionally, professionallytraced, tracedaqueous, aqueousneck, neckgravimetric, gravimetriccalibrator, calibratoruncertainty, uncertaintyreference, referencematerials, materialsastasol, astasoldeclared, declaredexpiration, expirationopening, openinganalysing
TRM - Al, As, Ba, Cd, Co, Cr, Cu, K, Mn, Mo, Ni, Pb, Se, Sr, Zn - Aqueous calibration solution ASTASOL® TUNE28
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net IDENTIFICATION SHEET Aqueous calibration solution ASTASOL® ASTASOL® TUNE28 This Identification sheet is designed in accordance with ISO Guide 31 Category: Traced reference materials Analytes: Al, As,…
Key words
parafilm, parafilmprofessionally, professionallytraced, tracedaqueous, aqueousneck, neckgravimetric, gravimetriccalibrator, calibratoruncertainty, uncertaintyreference, referencematerials, materialsastasol, astasoldeclared, declaredexpiration, expirationopening, openinganalysing
TRM - Ba, Bi, Ce, Co, Ho, In, Li, Mg, Ti, U, Y - Aqueous calibration solution ASTASOL® TUNE11E
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net IDENTIFICATION SHEET Aqueous calibration solution ASTASOL® ASTASOL® TUNE11E This Identification sheet is designed in accordance with ISO Guide 31 Category: Traced reference materials Analytes: Ba, Bi,…
Key words
parafilm, parafilmprofessionally, professionallydemineralized, demineralizedtraced, tracedboil, boilaqueous, aqueoussrms, srmsanalpure, analpureneck, neckgravimetric, gravimetriccalibrator, calibratordistilled, distilleduncertainty, uncertaintyreference, referencematerials
Other projects
GCMS
LCMS
Follow us
FacebookLinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike