Analysis of Sewage and Sewage Sludge
Applications | | ShimadzuInstrumentation
The accumulation and disposal of sewage sludge and effluent represent a growing environmental challenge. Trace and major heavy metals in these matrices can leach into soil and waterways, posing ecological and human health risks. Reliable, multi-element quantitation is therefore essential for compliance monitoring and risk assessment.
This study evaluates the performance of the Shimadzu ICPE-9000 inductively coupled plasma atomic emission spectrometer for simultaneous quantitation of elements ranging from low-level cadmium to high-concentration iron in both sewage sludge ash and treated wastewater. A secondary comparison was conducted using a Shimadzu ICP-MS (ICPM-8500) to validate the emission results.
Sample pretreatment protocols were developed for two matrices:
Calibration curves employed a multivariate polynomial fit with 1/I² weighting. The ICPE-9000’s automatic wavelength selection and dual axial/radial views enabled wide dynamic range detection in a single batch run.
Quantitation of B, Cd, Cr, Cu, Fe, Mn, Ni, Pb, and Zn yielded close agreement between ICPE-9000 and ICP-MS (deviations <10%). Concentrations in sludge ash ranged from 2.5 mg/kg Cd to 22 200 mg/kg Fe, while wastewater levels spanned 0.00004 mg/L Cd to 0.101 mg/L Fe. Spectral profiles confirmed negligible spectral interference under optimized conditions.
The ICPE-9000 enables rapid, simultaneous multi-element analysis across disparate concentration ranges without changing hardware settings. This approach streamlines environmental monitoring workflows for wastewater treatment plants, regulatory laboratories, and industrial QA/QC applications.
Advancements may include further miniaturization of plasma sources, enhanced software-driven interference correction, on-line process monitoring, and integration with machine learning for predictive water quality management. Coupling ICP emission with separation techniques (e.g., speciation analysis) will expand its utility in tracing element forms.
The Shimadzu ICPE-9000 demonstrates robust, high-sensitivity multi-element performance for sewage sludge and wastewater analysis. Its capacity for single-batch quantitation across a wide dynamic range offers significant operational efficiency and data reliability.
GD/MP/ICP-AES
IndustriesEnvironmental
ManufacturerShimadzu
Summary
Significance of the Topic
The accumulation and disposal of sewage sludge and effluent represent a growing environmental challenge. Trace and major heavy metals in these matrices can leach into soil and waterways, posing ecological and human health risks. Reliable, multi-element quantitation is therefore essential for compliance monitoring and risk assessment.
Objectives and Study Overview
This study evaluates the performance of the Shimadzu ICPE-9000 inductively coupled plasma atomic emission spectrometer for simultaneous quantitation of elements ranging from low-level cadmium to high-concentration iron in both sewage sludge ash and treated wastewater. A secondary comparison was conducted using a Shimadzu ICP-MS (ICPM-8500) to validate the emission results.
Methodology
Sample pretreatment protocols were developed for two matrices:
- Sewage sludge ash: 10 g digested with nitric acid, spiked with 40 ppm yttrium internal standard, diluted to 100 mL with hydrochloric acid.
- Sewage effluent: acid digestion with nitric and perchloric acids until white fumes appeared, fivefold concentration, and yttrium addition at 40 ppm.
Calibration curves employed a multivariate polynomial fit with 1/I² weighting. The ICPE-9000’s automatic wavelength selection and dual axial/radial views enabled wide dynamic range detection in a single batch run.
Used Instrumentation
- ICPE-9000 ICP emission spectrometer
- Coaxial nebulizer with bubbler and cyclone mist chamber
- Mini torch accessory
- Axial and radial observation modes
- Shimadzu ICPM-8500 for cross-validation
Key Results and Discussion
Quantitation of B, Cd, Cr, Cu, Fe, Mn, Ni, Pb, and Zn yielded close agreement between ICPE-9000 and ICP-MS (deviations <10%). Concentrations in sludge ash ranged from 2.5 mg/kg Cd to 22 200 mg/kg Fe, while wastewater levels spanned 0.00004 mg/L Cd to 0.101 mg/L Fe. Spectral profiles confirmed negligible spectral interference under optimized conditions.
Benefits and Practical Applications
The ICPE-9000 enables rapid, simultaneous multi-element analysis across disparate concentration ranges without changing hardware settings. This approach streamlines environmental monitoring workflows for wastewater treatment plants, regulatory laboratories, and industrial QA/QC applications.
Future Trends and Applications
Advancements may include further miniaturization of plasma sources, enhanced software-driven interference correction, on-line process monitoring, and integration with machine learning for predictive water quality management. Coupling ICP emission with separation techniques (e.g., speciation analysis) will expand its utility in tracing element forms.
Conclusion
The Shimadzu ICPE-9000 demonstrates robust, high-sensitivity multi-element performance for sewage sludge and wastewater analysis. Its capacity for single-batch quantitation across a wide dynamic range offers significant operational efficiency and data reliability.
References
- Japan Sewage Works Association. Sewage Test Methods, 1997.
- Prime Minister's Office Regulation No. 5, 1973: Industrial Waste Assessment Standards.
- JIS K0102-1998: Testing Methods for Industrial Wastewater.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Plants – 2
|Shimadzu|Applications
Inductively Coupled Plasma Atomic Emission Spectrometry Analysis of Plants – 2 Description The multi-type ICPE-9000 ICP emission spectrometer was used to analyze several plant standards (tea leaf, olive, citrus leaf). Figs. 1 to 3 show the semi-quantitation values, and…
Key words
ensit, ensitオリーブ, オリーブシトラス, シトラスint, intconcent, concentnone, noneleaf, leafcitrus, citrusolive, oliverat, rattea, teaion, ionvalue, valuecertified, certifiedbelow
Analysis of River Water / ICPE-9000
|Shimadzu|Applications
Inductively Coupled Plasma Atomic Emission Spectrometry Analysis of River Water / ICPE-9000 Description On May 30, 2003, the tap water quality standard was greatly revised in Japan, and this revision made notification of a new inspection method. Arsenic, selenium,…
Key words
ensit, ensitconcent, concentint, intnone, noneitem, itemrat, ratwater, waterquality, qualitystandard, standardion, ionministerial, ministerialordinance, ordinanceconsideration, considerationhydride, hydriderequiring
Analysis of Fertilizer
|Shimadzu|Applications
Inductively Coupled Plasma Atomic Emission Spectrometry Analysis of Fertilizer Description Fertilizers classified as general fertilizers made from sludge are subject to official standards, including minimum content of principal ingredients, maximum limit for harmful constituents, etc., according to the Fertilizer…
Key words
ensit, ensitint, intconcent, concentnone, nonerat, ratfertilizer, fertilizerquantitation, quantitationresult, resultion, ionlimit, limitbelow, belowsample, samplerecovery, recoverydetection, detectionmin
Analysis of Pond Sediment
|Shimadzu|Applications
Inductively Coupled Plasma Atomic Emission Spectrometry Analysis of Pond Sediment Description The multi-type ICPE-9000 ICP emission spectrometer was used to analyze pond sediment. With the ICPE-9000, the semi-quantitation results can easily be obtained from the database (qualitative function), without…
Key words
ensit, ensitint, intnone, noneconcent, concentcond, condrat, ratquantitation, quantitationion, ionchamber, chambermisting, mistingpond, pondparentheses, parenthesescoaxial, coaxialplasma, plasmacyclone