Analysis of Multiple Elements in Drinking Water by ICPE-9820

Applications | 2014 | ShimadzuInstrumentation
GD/MP/ICP-AES
Industries
Environmental
Manufacturer
Shimadzu

Summary

Significance of the Topic


Ensuring safe drinking water requires accurate monitoring of major and trace elements to comply with regulations and protect public health.

Objectives and Study Overview


This study evaluates the performance of the Shimadzu ICPE-9820 ICP-AES system combined with an ultrasonic nebulizer for simultaneous multi-element analysis in river water, addressing elements ranging from major constituents to trace toxic metals.

Methodology


Water samples from certified reference materials were acidified, heated to dissolve matrix components, spiked with yttrium as an internal standard, and diluted to volume.
Calibration curves were constructed using both axial and radial viewing modes to cover concentration ranges from µg/L to mg/L without additional dilution.

Used Instrumentation


  • Shimadzu ICPE-9820 ICP-AES with echelle spectrometer and CCD detector
  • Mini-torch for reduced argon consumption
  • Ultrasonic nebulizer UAG-1 for low-concentration elements
  • Standard nebulizer for major elements
  • Eco mode and vacuum-type spectrometer to minimize gas and power use

Main Results and Discussion


Calibration for sodium (Na) showed excellent linearity up to 200 mg/L in both axial (r=0.99998) and radial (r=1.00000) modes, eliminating the need for dilution.
Detection limits for all elements were below one tenth of regulatory thresholds.
Quantitative results for certified reference materials matched certified values across trace and major elements.
Spectral profiles confirmed clear peak resolution for Cd, Cr, and Pb.

Benefits and Practical Applications


  • Simultaneous multi-element analysis increases sample throughput
  • Wide dynamic range permits analysis of trace and high-concentration elements without multiple dilutions
  • Operating cost reduction via low gas consumption and Eco mode
  • Suitable for routine drinking water monitoring in environmental and regulatory laboratories

Future Trends and Potential Uses


Advances may include portable ICP systems for field analysis, integration with AI for automated data interpretation, real-time monitoring platforms, and cloud-based data management, further enhancing water quality surveillance.

Conclusion


The Shimadzu ICPE-9820 system offers a robust, sensitive, and cost-effective solution for comprehensive drinking water elemental analysis, ensuring regulatory compliance and operational efficiency.

References


  • US-EPA National Primary Drinking Water Regulations (2012)
  • WHO Guidelines for Drinking-Water Quality, 4th ed. (2011)

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Analysis of Nutritional and Harmful Elements in Powdered Milk by ICPE-9820 / HVG-1
LAAN-A-CP-E029 Application News J116 Inductively Coupled Plasma Atomic Emission Spectrometry Analysis of Nutritional and Harmful Elements in Powdered Milk by ICPE-9820 / HVG-1 No. n Introduction Minerals required for infant growth are well balanced in powdered infant formula. According to…
Key words
std, stdnmij, nmijflowrate, flowratemilk, milkelements, elementspowdered, powderedsolution, solutioninfant, infantspike, spikepowder, powderplasma, plasmavalue, valueobservation, observationmeasurement, measurementgas
Simultaneous Analysis of Trace and Major Elements in Rice by ICPE-9820
LAAN-A-CP-E016 Application News J103 Inductively Coupled Plasma Atomic Emission Spectrometry Simultaneous Analysis of Trace and Major Elements in Rice by ICPE-9820 No. n Sample Brown rice powder standard samples NIES No. 10-a, -b, and -c radial view than with the…
Key words
rice, ricebrown, brownelements, elementsview, viewradial, radialvalue, valueflowrate, flowrateintensity, intensitycertified, certifiedconcentration, concentrationsimultaneous, simultaneousplasma, plasmaaxial, axialanalysis, analysisfarmland
Shimadzu ICPE-9800 Series
Shimadzu ICPE-9800 Series
2020|Shimadzu|Brochures and specifications
C113-E015G Simultaneous ICP Atomic Emission Spectrometers ICPE-9800 Series BEST for All Laboratories ICPE-9800 Series of simultaneous ICP atomic emission spectrometers are next-generation systems that offer the superior accuracy necessary to simultaneously and quickly analyze multiple elements regardless of their concentration…
Key words
torch, torchaxial, axialicp, icpspectrometers, spectrometerswavelengths, wavelengthssimultaneous, simultaneousradial, radialmini, miniatomic, atomicemission, emissionhydrofluoric, hydrofluoricchamber, chamberorganic, organicpurge, purgegas
Simultaneous Multi-Element Analysis of Farmland Soil Extracts Using the ICPE-9820
Simultaneous ICP Atomic Emission Spectrometer Application News ICPE-9820 Simultaneous Multi-Element Analysis of Farmland Soil Extracts Using the ICPE-9820 Yuta Ikado and Susumu Hashimoto User Benefits  The ICPE-9820 can quickly analyze farmland soil for multiple elements simultaneously.  The ICPE-9820…
Key words
axial, axialconstituents, constituentsexchangeable, exchangeablesoil, soilelements, elementstest, testoxide, oxidecontent, contentcadmium, cadmiumlimit, limitradial, radialsample, samplespiked, spikedconstituent, constituentcalibration
Other projects
GCMS
LCMS
Follow us
FacebookLinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike