Shimadzu UV Talk letter Vol. 21
Others | 2023 | ShimadzuInstrumentation
Accurate ultraviolet–visible (UV–VIS) absorption spectroscopy underpins a wide range of applications in chemical analysis, life sciences, and industrial quality control. Optimizing measurement parameters (such as slit width, scan speed, and data interval) ensures reliable spectral data, while micro-volume cells extend capabilities to scarce or highly absorbing samples. Furthermore, clear definitions (e.g., absorbance vs. optical density) and advanced tools (e.g., fully automated photoreaction quantum yield systems) accelerate experimental workflows and improve reproducibility.
This whitepaper aims to:
The work employs a Shimadzu UV-1900i UV–VIS spectrophotometer combined with:
The optimized parameter settings support robust spectral acquisition for academic and industrial laboratories. Micro-volume cells conserve valuable or limited samples and streamline high-absorbance analyses. Clear conceptual distinctions aid in method selection for nucleic acid/protein quantification and turbid sample assessment. The Lightway system offers a rapid, error-free approach to photochemical efficiency studies, benefiting catalyst development and photobiology research.
Emerging directions include integration of machine-learning algorithms for real-time parameter optimization, further miniaturization of sampling cells, expansion to near-infrared and ultrafast spectral domains, and greater automation of photochemical workflows. Advanced cell materials and microfluidic platforms may enable on-chip spectral analysis, while broader adoption of fully automated quantum yield systems will support high-throughput screening of light-driven processes.
Proper selection of UV–VIS measurement parameters significantly enhances data quality, while micro-volume cells broaden analytical capabilities for scarce or concentrated samples. Clear understanding of absorbance vs. optical density ensures accurate interpretation of spectrophotometric results. The PQY-01 Lightway system demonstrates how automation can streamline photoreaction studies and improve reproducibility. Collectively, these advancements contribute to more efficient, accurate, and versatile analytical workflows.
No external literature was cited in the original document.
UV–VIS spectrophotometry
IndustriesManufacturerShimadzu
Summary
Importance of Topic
Accurate ultraviolet–visible (UV–VIS) absorption spectroscopy underpins a wide range of applications in chemical analysis, life sciences, and industrial quality control. Optimizing measurement parameters (such as slit width, scan speed, and data interval) ensures reliable spectral data, while micro-volume cells extend capabilities to scarce or highly absorbing samples. Furthermore, clear definitions (e.g., absorbance vs. optical density) and advanced tools (e.g., fully automated photoreaction quantum yield systems) accelerate experimental workflows and improve reproducibility.
Objectives and Overview of the Article
This whitepaper aims to:
- Elucidate how key UV–VIS measurement settings influence spectral resolution, noise, and acquisition time.
- Demonstrate the practical use of micro-volume measurement cells (Nano Stick-S and TrayCell) for small-volume and high-absorbance samples.
- Clarify the conceptual difference between absorbance and optical density.
- Introduce the PQY-01 Lightway photoreaction evaluation system for automated photon counting and quantum yield determination.
Methodology and Instrumentation
The work employs a Shimadzu UV-1900i UV–VIS spectrophotometer combined with:
- Nano Stick-S micro-volume cell (0.5 mm path length, 2 µL sample).
- TrayCell (selectable 0.1, 0.2, 1.0, 2.0 mm path lengths; 0.7–10 µL sample range).
- 10 mm quartz cell for standard measurements.
- Nexis GC-2030 gas chromatograph and Nexera series liquid chromatograph for photoproduct analysis.
- PQY-01 Lightway photoreaction evaluation system with LED light source for precise photon flux measurement.
Main Results and Discussion
- Slit Width: Narrower slits improve wavelength resolution (e.g., distinct benzene peaks at 1 nm vs. smoothed peaks at 5 nm) at the cost of increased noise.
- Scan Speed: Slower scan speeds yield reduced baseline noise (e.g., extra-slow vs. survey mode on UV-1900i) but require longer measurement times, with potential minor peak shifts at higher speeds.
- Data Interval: Finer intervals (0.05–0.1 nm) provide more accurate peak positioning but lengthen acquisition time; coarser intervals (1–5 nm) are suited for rapid surveys.
- Micro-Volume Cells: Both Nano Stick-S and TrayCell achieved excellent linearity (R²=0.9999) in Lambda-DNA quantification (27.5–440 ng/µL). TrayCell showed slightly better repeatability (CV ~0.36% vs. 0.43%).
- High-Absorbance Samples: TrayCell (0.2 mm path length) enabled direct measurement of a red stain sample with only a 100× dilution, compared to a 5,000× dilution for a 10 mm cell.
- Absorbance vs. Optical Density: Absorbance quantifies light loss due to molecular absorption (Lambert–Beer law), whereas optical density encompasses both absorption and scattering, relevant for turbid or colloidal samples.
- Lightway System: Automated photoreaction quantum yield measurements of a Ru–Re supramolecular catalyst for CO₂ reduction yielded ΦCO = 40%, correlating CO production (via GC) with absorbed photon counts without chemical actinometers.
Benefits and Practical Applications
The optimized parameter settings support robust spectral acquisition for academic and industrial laboratories. Micro-volume cells conserve valuable or limited samples and streamline high-absorbance analyses. Clear conceptual distinctions aid in method selection for nucleic acid/protein quantification and turbid sample assessment. The Lightway system offers a rapid, error-free approach to photochemical efficiency studies, benefiting catalyst development and photobiology research.
Future Trends and Potential Applications
Emerging directions include integration of machine-learning algorithms for real-time parameter optimization, further miniaturization of sampling cells, expansion to near-infrared and ultrafast spectral domains, and greater automation of photochemical workflows. Advanced cell materials and microfluidic platforms may enable on-chip spectral analysis, while broader adoption of fully automated quantum yield systems will support high-throughput screening of light-driven processes.
Conclusion
Proper selection of UV–VIS measurement parameters significantly enhances data quality, while micro-volume cells broaden analytical capabilities for scarce or concentrated samples. Clear understanding of absorbance vs. optical density ensures accurate interpretation of spectrophotometric results. The PQY-01 Lightway system demonstrates how automation can streamline photoreaction studies and improve reproducibility. Collectively, these advancements contribute to more efficient, accurate, and versatile analytical workflows.
Reference
No external literature was cited in the original document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Quantitation of Nucleic Acids – Trace Measurement Using TrayCell and Nano Stick –
2018|Shimadzu|Applications
LAAN-A-UV-E072 Application News No. A577 Spectrophotometric Analysis Quantitation of Nucleic Acids – Trace Measurement Using TrayCell and Nano Stick – Ultraviolet-visible (UV-VIS) spectrophotometers are used in quantitative and qualitative analysis of substances in many fields. Purity confirmation and quantitation of…
Key words
nucleic, nucleicabsorbance, absorbancetraycell, traycellquantitation, quantitationstick, stickvalue, valuenano, nanomeasurement, measurementindicate, indicatedripped, drippedcorrelation, correlationacid, acidwavelength, wavelengthnews, newsdeviation
UV-1900i Plus UV-Vis Spectrophotometer
2025|Shimadzu|Brochures and specifications
C101-E181 UV-Vis Spectrophotometer UV-1900i Plus Navigate Your Way Refined User-Friendliness Easy-to-use touch-screen display Faster response speed with adoption of a new CPU Various Functions for Comfortable Daily Measurement User support with assist and shutdown/wakeup functions High Performance to Meet Diverse…
Key words
measurement, measurementfunction, functionfunctions, functionswakeup, wakeuplabsolutions, labsolutionsvis, visdata, datakinetics, kineticsshutdown, shutdowninforms, informsuser, userinstrument, instrumentmanagement, managementλdna, λdnacorrection
Guide to Biopharmaceutical Solutions —From Cell Line Optimization to Pharmacokinetics—
2021|Shimadzu|Brochures and specifications
C10G-E089 Guide to Biopharmaceutical Solutions —From Cell Line Optimization to Pharmacokinetics— Solutions Designed for Biopharmaceutical Workflows Optimization DNA/RNA Analysis P. 8–9 P. 4–7 Analysis of Metal Elements in Culture Solutions P. 12–13 Colony Picking Analysis of Chemical Components in Culture…
Key words
culture, culturepharmacokinetics, pharmacokineticsindex, indexcell, cellmouse, mousecharacterization, characterizationothers, otherspurification, purificationcontrol, controlquality, qualityoptimization, optimizationmeasurement, measurementanalysis, analysisprinciple, principleoperating
Guide to Biopharmaceutical Solutions — From Cell Line Optimization to Pharmacokinetics —
2021|Shimadzu|Guides
C10G-E089 Guide to Biopharmaceutical Solutions —From Cell Line Optimization to Pharmacokinetics— Solutions Designed for Biopharmaceutical Workflows Optimization DNA/RNA Analysis P. 8–9 P. 4–7 Analysis of Metal Elements in Culture Solutions P. 12–13 Colony Picking Analysis of Chemical Components in Culture…
Key words
culture, culturepharmacokinetics, pharmacokineticsindex, indexcell, cellmouse, mousecharacterization, characterizationothers, otherspurification, purificationcontrol, controlquality, qualityoptimization, optimizationmeasurement, measurementanalysis, analysisprinciple, principleoperating