Agilent 7500 Series ICP-MS - Specifications
Brochures and specifications | 2007 | Agilent TechnologiesInstrumentation
Inductively coupled plasma mass spectrometry (ICP-MS) has become the gold standard for multi-element trace analysis across environmental, pharmaceutical, clinical and industrial laboratories. The high sensitivity, broad dynamic range and rapid multi-element capability of the Agilent 7500 Series ICP-MS enable demanding applications such as regulatory compliance, contaminant screening and advanced speciation studies.
This whitepaper presents a comprehensive overview of the Agilent 7500 Series ICP-MS family, detailing system architecture, performance specifications and optional configurations. The main goal is to guide end users in selecting and applying the 7500cx and 7500cs models for routine and advanced analytical tasks.
The 7500 Series integrates:
Performance data demonstrate detection limits typically in the low-ppt range (e.g., Fe(56) < 3 ppt), CeO⁺/Ce⁺ ratios below 1.5 %, and RSDs better than 2 % at 1 ppb for most elements. The ORS cell effectively suppresses interferences such as ArCl⁺, NO⁺ and doubly charged species, improving accuracy in complex matrices. The robust design yields stable signals over extended runs, with minimal mass drift and high throughput of up to 150 elements per minute.
The 7500 Series offers:
Emerging directions include tandem ICP-MS/MS for enhanced interference control, integration of AI-driven data processing for real-time decision support, and miniaturized plasma sources for field-portable analysis. Expanded chemometric tools will further enrich speciation and isotopic ratio applications.
The Agilent 7500 Series ICP-MS family combines sensitivity, robustness and flexibility to meet today’s most challenging elemental analysis tasks. With proven performance and modular configurations, these instruments serve a wide range of laboratories seeking reliable trace-level quantification and speciation capabilities.
[1] Agilent Technologies. Agilent 7500 Series ICP-MS Specifications and Operating Manual. April 2007.
ICP/MS
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
Inductively coupled plasma mass spectrometry (ICP-MS) has become the gold standard for multi-element trace analysis across environmental, pharmaceutical, clinical and industrial laboratories. The high sensitivity, broad dynamic range and rapid multi-element capability of the Agilent 7500 Series ICP-MS enable demanding applications such as regulatory compliance, contaminant screening and advanced speciation studies.
Objectives and Overview
This whitepaper presents a comprehensive overview of the Agilent 7500 Series ICP-MS family, detailing system architecture, performance specifications and optional configurations. The main goal is to guide end users in selecting and applying the 7500cx and 7500cs models for routine and advanced analytical tasks.
Instrumentation Used
The 7500 Series integrates:
- Sample introduction: MicroMist nebulizer, PFA nebulizer and temperature-controlled spray chamber.
- Plasma source: 27 MHz solid-state generator, load-matching network.
- Collision/reaction cell (ORS) employing He, H₂ and gas mixtures for polyatomic interference removal.
- Quadrupole mass filter with fast scanning electronics and a dynamic mass range up to 10¹⁰ counts.
- Detector: dual-mode analog and discrete dynode electron multiplier for sub-ppt detection limits.
- Vacuum system: two turbo pumps delivering high vacuum in the ion optics and quadrupole regions.
- Optional interfaces: GC-ICP-MS, HPLC/IC-ICP-MS and an autosampler for speciation work.
Key Results and Discussion
Performance data demonstrate detection limits typically in the low-ppt range (e.g., Fe(56) < 3 ppt), CeO⁺/Ce⁺ ratios below 1.5 %, and RSDs better than 2 % at 1 ppb for most elements. The ORS cell effectively suppresses interferences such as ArCl⁺, NO⁺ and doubly charged species, improving accuracy in complex matrices. The robust design yields stable signals over extended runs, with minimal mass drift and high throughput of up to 150 elements per minute.
Benefits and Practical Applications
The 7500 Series offers:
- Ultra-low detection limits for environmental, food and clinical testing.
- Wide dynamic range (10 orders of magnitude) for simultaneous trace and major element analysis.
- Collision/reaction cell options to tailor interference removal strategies.
- Seamless coupling with chromatographic systems for speciation and fractionation studies.
- User-friendly software with automated tuning, calibration and QA/QC routines.
Future Trends and Opportunities
Emerging directions include tandem ICP-MS/MS for enhanced interference control, integration of AI-driven data processing for real-time decision support, and miniaturized plasma sources for field-portable analysis. Expanded chemometric tools will further enrich speciation and isotopic ratio applications.
Conclusion
The Agilent 7500 Series ICP-MS family combines sensitivity, robustness and flexibility to meet today’s most challenging elemental analysis tasks. With proven performance and modular configurations, these instruments serve a wide range of laboratories seeking reliable trace-level quantification and speciation capabilities.
References
[1] Agilent Technologies. Agilent 7500 Series ICP-MS Specifications and Operating Manual. April 2007.
Similar PDF
Agilent Cary UV Workstation Software Registration Instructions
2023|Agilent Technologies|Manuals
Agilent Cary UV Workstation Software Registration Instructions 软件注册说明 ソフトウェアの登録方法 Select English, Chinese, or Japanese instructions. 选择英语或中文说明。 英語、中国語または日本語の手順を選択してください。 Introduction SubscribeNet allows users to manage software entitlements, order media or download software. We recommend users renew subscriptions annually to have full access…
Key words
cary, caryソフトウェア, ソフトウェアライセンス, ライセンスsubscribenet, subscribenetクリック, クリックworkstation, workstationコンピューター, コンピューターライセンスファイル, ライセンスファイルmac, macログイン, ログインアップグレード, アップグレードアカウント, アカウントコントロールパネル, コントロールパネルコード, コードopenlab
START INSTALLATION CARY 60
2016|Agilent Technologies|Manuals
6.0 1 RUN TUTORIALS Double-click Cary WinUV on the computer desktop. 双击计算机桌面上的 Cary WinUV。 Haga doble clic en Cary WinUV en el escritorio del equipo. Clique duas vezes em Cary WinUV na área de trabalho do computador. コンピュータのデスクトップにあるCary WinUVを ダブルクリックします。…
Key words
cary, carywinuv, winuvインストール, インストールhaga, hagaクリック, クリックダブルクリック, ダブルクリックclic, clicagilentcarywinuvsetup, agilentcarywinuvsetupduas, duastrabalho, trabalhoハードウェア, ハードウェアvalidate, validateárea, áreaコンピュータ, コンピュータデスクトップ
Guide to Biopharmaceutical Solutions — From Cell Line Optimization to Pharmacokinetics —
2021|Shimadzu|Guides
C10G-E089 Guide to Biopharmaceutical Solutions —From Cell Line Optimization to Pharmacokinetics— Solutions Designed for Biopharmaceutical Workflows Optimization DNA/RNA Analysis P. 8–9 P. 4–7 Analysis of Metal Elements in Culture Solutions P. 12–13 Colony Picking Analysis of Chemical Components in Culture…
Key words
culture, culturepharmacokinetics, pharmacokineticsindex, indexcell, cellmouse, mousecharacterization, characterizationothers, otherspurification, purificationcontrol, controlquality, qualityoptimization, optimizationmeasurement, measurementanalysis, analysisprinciple, principleoperating
Guide to Biopharmaceutical Solutions —From Cell Line Optimization to Pharmacokinetics—
2021|Shimadzu|Brochures and specifications
C10G-E089 Guide to Biopharmaceutical Solutions —From Cell Line Optimization to Pharmacokinetics— Solutions Designed for Biopharmaceutical Workflows Optimization DNA/RNA Analysis P. 8–9 P. 4–7 Analysis of Metal Elements in Culture Solutions P. 12–13 Colony Picking Analysis of Chemical Components in Culture…
Key words
culture, culturepharmacokinetics, pharmacokineticsindex, indexcell, cellmouse, mousecharacterization, characterizationothers, otherspurification, purificationcontrol, controlquality, qualityoptimization, optimizationmeasurement, measurementanalysis, analysisprinciple, principleoperating