ICPMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Agilent 4100/4200 Series MP-AES Supplies - Quick Reference Guide

Guides | 2019 | Agilent TechnologiesInstrumentation
GD/MP/ICP-AES
Industries
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


In modern analytical laboratories, maintaining a continuous workflow with minimal instrument downtime is essential for productivity and data quality. The Agilent 4100/4200 MP-AES (Microwave Plasma Atomic Emission Spectroscopy) systems rely on a wide array of consumables and spare parts to ensure consistent performance. A well-organized reference for these supplies enables rapid procurement, supports preventive maintenance, and reduces the risk of operational delays.

Objectives and Overview


This guide aims to present a concise, categorized listing of the most commonly ordered supplies and parts for Agilent 4100/4200 series MP-AES instruments. By providing part numbers, descriptions, and intended applications, the reference simplifies the ordering process and aids laboratories in inventory planning.

Methodology and Used Instrumentation


The document compiles manufacturer-provided data on instrument consumables, organized by function. The primary instrumentation addressed includes the Agilent 4100 and 4200/4210 MP-AES systems. Consumable categories cover sample introduction components, autosampler accessories, tubing, racks, and calibration solutions.

Main Contents and Discussion


Key consumable groups:
  • Torches and torch accessories: Standard and inert easy-fit torches, clamps, and cleaning stands.
  • Nebulizers and spray chambers: Concentric and inert models for aqueous, HF, and high-TDS samples, in single-pass and double-pass configurations.
  • Pump tubing and connectors: Peristaltic tubes tailored for organic, aqueous, and high-TDS samples, including SolvaFlex and Santoprene materials.
  • Application kits: Preassembled introduction kits for high-sensitivity, routine aqueous, or HF applications.
  • Autosampler supplies: Probes, tubing for rinse pumps, and sample racks compatible with Agilent SPS 4 and SPS 3.
  • Calibration and internal standard solutions: Multi-element mixes for wavelength calibration, internal standards, and ionization buffers.

Benefits and Practical Applications


Standardizing on genuine Agilent consumables ensures:
  • Optimized plasma stability and signal reproducibility.
  • Extended instrument lifetime through proper material compatibility.
  • Reduced risk of contamination or component failure.
  • Streamlined procurement and inventory management.

Future Trends and Potential Uses


Emerging developments may include digital supply-chain integration, real-time monitoring of consumable wear, and advanced materials for enhanced chemical resistance. Cloud-based ordering platforms linked to instrument software could automate reorder points and support predictive maintenance.

Conclusion


The Agilent 4100/4200 MP-AES supplies reference provides a comprehensive, easy-to-use catalog of essential consumables. Adopting this guide facilitates efficient lab operations, supports high-quality analytical results, and minimizes instrument downtime.

References


No external literature references were provided in the original vendor documentation.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent 5800/5900 and 5100/5110 ICP-OES supplies - Quick Reference Guide
Quick Reference Guide Agilent 5000 Series ICP-OES 5800/5900 and 5100/5110 ICP-OES supplies Agilent Technologies is committed to optimizing your laboratory’s productivity, so we have produced this list of the most commonly ordered supplies and parts for the Agilent 5800/5900 and…
Key words
icp, icpstandard, standardtubing, tubingsupplies, suppliesouter, outerkit, kitpart, partspray, spraychamber, chamberorganics, organicstabs, tabstorches, torchestorch, torchtube, tubeinert
Agilent 5800/5900 and 5100/5110 ICP-OES supplies
Agilent 5800/5900 and 5100/5110 ICP-OES supplies
2024|Agilent Technologies|Guides
Quick Reference Guide Agilent 5000 Series ICP-OES 5800/5900 and 5100/5110 ICP-OES supplies Agilent Technologies is committed to optimizing your laboratory’s productivity, so we have produced this list of the most commonly ordered supplies and parts for the Agilent 5800/5900 and…
Key words
icp, icpstandard, standardtubing, tubinginert, inerttabs, tabskit, kitspray, sprayouter, outerchamber, chamberpart, partsupplies, suppliesorganics, organicstorches, torchestube, tubetorch
Agilent 700 Series Radial ICP-OES Supplies - Quick Reference Guide
Quick Reference Guide Agilent 700 Series Radial ICP-OES Supplies Agilent supplies for Agilent instruments Agilent is committed to optimizing your laboratory’s productivity. This reference guide shows the most commonly ordered supplies and parts for the 700 series radial (vertically orientated)…
Key words
part, partnumber, numbertubing, tubingsupplies, supplieschamber, chamberspray, spraymasters, masterssturman, sturmanconnecting, connectingagilent, agilentcyclonic, cyclonicspare, spareorganics, organicstorch, torchpiece
Agilent 700 Series Axial ICP-OES Supplies - Quick Reference Guide
Quick Reference Guide Agilent 700 Series Axial ICP-OES Supplies Agilent supplies for Agilent instruments Agilent is committed to optimizing your laboratory’s productivity. This reference guide shows the most commonly ordered supplies and parts for the 700 series axial (horizontally orientated)…
Key words
tubing, tubingpart, partnumber, numbersupplies, suppliesconnecting, connectingspare, sparekit, kitagilent, agilentpump, pumpspray, sprayorganics, organicssemidemountable, semidemountablegazfit, gazfitrack, rackoes
Other projects
GCMS
LCMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike