The Basics of UV-Vis Spectrophotometry

Guides | 2021 | Agilent TechnologiesInstrumentation
UV–VIS spectrophotometry
Industries
Manufacturer
Agilent Technologies

Summary

Importance of the topic


UV–Vis spectrophotometry remains one of the most widely used analytical techniques in chemistry and related fields because it provides rapid, non-destructive measurements of absorption, transmittance and reflectance over the ultraviolet and visible wavelength ranges. Its linear response to concentration (Beer–Lambert law), ease of use, and compatibility with a variety of accessories make it indispensable for identification, quantification, kinetic studies, color measurement, structural analysis, and process monitoring.

Objectives and study overview


This primer delivers a comprehensive introduction to UV–Vis spectrophotometry. It reviews the basic physical principles, explains modern instrument design, and offers detailed guidance on selecting cell types, solvents, spectral bandwidths, stray-light control, temperature and stirring conditions. Common applications—from single-point concentration assays and multicomponent analysis to thermal melting of biomolecules—are illustrated and discussed.

Methodology and experimental parameters


  • Electromagnetic principles: UV (190–400 nm) and visible (400–900 nm) absorbance arises from electronic transitions superimposed on vibrational/rotational sublevels.
  • Optical cells: Choose pathlengths (0.1–100 mm) according to absorbance (<0.2 Abs dilute samples use long cells; >3 Abs concentrated samples use short cells).
  • Materials: Quartz or fused silica for full UV–NIR range; optical glass (>334 nm); plastics for visible only.
  • Spectral bandwidth (SBW): Set SBW to ~1/10 of natural bandwidth; typical routine SBW is 1.5 nm; research systems allow variable SBW to trade resolution against signal-to-noise.
  • Stray light: Causes flattening of high-absorbance bands and deviation from Beer’s law; minimized by double monochromators or reference detectors.
  • Temperature control: Peltier or water-circulated cuvette holders support thermostatted and ramped measurements; direct in-cuvette probes and stirring ensure sample homogeneity.
  • Data collection: Single- or double-beam optics; single-point and scanning kinetics; stopped-flow accessories for millisecond-scale reactions.

Instrumentation used


  • Light sources: Deuterium arc lamp (185–400 nm), tungsten-halogen lamp (350–3000 nm), xenon flash lamp (185–2500 nm).
  • Monochromators: Holographic diffraction gratings in single or double configurations; adjustable entrance/exit slits define SBW.
  • Detectors: Photomultiplier tubes (PMTs) for high sensitivity (200–900 nm); silicon photodiodes (170–1100 nm); InGaAs (800–2500 nm); PbS detectors (1000–3500 nm).
  • Accessories: Standard and micro cuvettes, flow cells, fiber-optic probes, thermostatted and stir-equipped sample holders, rapid-mix/stopped-flow modules.

Main results and discussion


The instrument layout and component choices determine performance metrics such as wavelength accuracy, photometric linearity, stray-light rejection, and scanning speed. Dual-beam designs with reference detectors or double monochromators minimize drift and stray light. Variable SBW and high-throughput detectors enhance the resolution-noise trade-off. Temperature control and stirring accessories extend applications to thermal denaturation of proteins and nucleic acids. Rapid mix techniques enable kinetic measurements from milliseconds to hours.

Benefits and practical applications


  • Concentration determination: Reliable assays based on Beer’s law for pharmaceuticals, environmental analytes, biomolecules.
  • Kinetic studies: Single-wavelength tracing or full-spectrum scanning of reaction progress, including stopped-flow for fast reactions.
  • Identity confirmation: Spectral matching and derivative analysis for quality control of compounds and materials.
  • Color measurement: Quantitative assessment of transmitted or reflected visible spectra for coatings, textiles, and biological assays.
  • Structural analysis: Monitoring of protein folding/unfolding, nucleic acid melting, conformational changes via absorbance shifts.
  • Multicomponent analysis: Least-squares and overdetermined methods for mixtures with overlapping spectra.

Future trends and potential applications


Advances in light sources (high-intensity LEDs, tunable lasers), detector arrays, and microfluidics will drive higher throughput and miniaturization. Machine-learning-supported multivariate analysis promises improved accuracy in complex mixtures. Fiber-optic and imaging probes will expand in-situ and on-line process monitoring in bioreactors, environmental sensors, and portable diagnostics.

Conclusion


UV–Vis spectrophotometry combines robust physical principles with flexible instrument architectures to meet diverse analytical challenges. Proper selection of optical cells, spectral parameters, and accessories is critical for maximizing accuracy and sensitivity. Modern developments in temperature control, rapid kinetics, and multicomponent algorithms continue to extend its applicability across research, manufacturing, and clinical laboratories.

References


  • Kisner H.; Brown W.; Kavarnos G. Multiple analytical frequencies and standards for the least-squares analysis of serum lipids. Anal. Chem. 1983, 55, 1703.
  • Maris M.; Brown C.; Lavery D. Nonlinear multicomponent analysis by infrared spectrophotometry. Anal. Chem. 1983, 55, 1694.
  • Zwart A.; van Kampen E.; Zijlstra W. Multicomponent analysis of hemoglobin derivatives with a reversed-optics instrument. Clin. Chem., 1984, 30, 373.
  • Clinical and Laboratory Standards Institute. Erythrocyte Protoporphyrin Testing; Approved Guideline, Vol. 16, No. 8, 1996.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Pharmaceutical Analysis Using UV-Vis: Compliance with USP Chapter <857>, and European Pharmacopoeia (Ph. Eur. Chapter 2.2.25)
Application Note Pharmaceutical Analysis Using UV-Vis: Compliance with USP Chapter <857>, and European Pharmacopoeia (Ph. Eur. Chapter 2.2.25) Meeting the requirements of the global pharmacopeias with the Agilent Cary 3500 UV-Vis Introduction UV-Vis spectroscopy is a widely used analytical technique…
Key words
absorbance, absorbancewavelength, wavelengthphotometric, photometricstray, straylight, lightpositions, positionsholmium, holmiumvis, viscontrol, controltest, testtolerances, tolerancesrecommended, recommendedtests, testsreference, referencescans
Effects of Filter Composition, Spectral Bandwidth, and Pathlength on Stray Light Levels in the Near-Infrared Region
Technical Overview Effects of Filter Composition, Spectral Bandwidth, and Pathlength on Stray Light Levels in the Near-Infrared Region Evaluating stray light levels on the Agilent Cary 5000/7000 UV-Vis-NIR spectrophotometers Authors Abstract Wesam Alwan and Travis Burt Agilent Technologies, Inc. Stray…
Key words
stray, straylight, lightwavelength, wavelengthspectrophotometer, spectrophotometerbandwidth, bandwidthdibromomethane, dibromomethanesbw, sbwlevels, levelsabsorbance, absorbancepathlength, pathlengthnir, nirradiation, radiationvalues, valuesspectral, spectralmeasured
Kinetics of an Oscillating Reaction using Temperature-Controlled UV-Vis Spectroscopy
Application Note Academia Kinetics of an Oscillating Reaction using Temperature-Controlled UV-Vis Spectroscopy Characterizing the Briggs-Rauscher reaction at four temperatures simultaneously using an Agilent Cary 3500 UV-Vis Authors Marc-André Gagnon, Claire Cislak, and Wesam Alwan Agilent Technologies, Inc. Abstract The Briggs-Rauscher…
Key words
briggs, briggsrauscher, rauscheroscillation, oscillationreaction, reactionmulticell, multicellcolor, colortemperature, temperaturevis, viskinetic, kinetictemperatures, temperaturesoscillating, oscillatingpeltier, peltierdecay, decayspectrophotometer, spectrophotometermultizone
Measurement of Opaque Liquids with UV-Vis and ATR
Measurement of Opaque Liquids with UV-Vis and ATR
2025|Agilent Technologies|Applications
Application Note Energy & Chemicals Measurement of Opaque Liquids with UV-Vis and ATR Combining the Agilent Cary 60 UV-Vis spectrophotometer with an ATR fiber-optic probe Authors Alex Clarke Hellma UK Ltd Rob Wills Agilent Technologies LDA UK Ltd Abstract The…