Importance of the Topic


Diesel quality parameters such as cetane index, flash point, cold filter plug point (CFPP), distillation endpoint (D95), and viscosity are critical for engine performance, fuel safety, and cold weather operation. Traditional reference methods are time-consuming and require multiple instruments and reagents, creating a need for a rapid, combined analysis approach.

Study Objectives and Overview


This study aims to evaluate the feasibility of visible and near-infrared (Vis-NIR) spectroscopy using the XDS RapidLiquid Analyzer for simultaneous, reagent-free determination of key diesel quality parameters. The goal is to compare Vis-NIR predictions against standard methods in terms of accuracy and precision.

Methodology and Instrumentation


Analysis was performed in transmission mode over 400–2500 nm at a controlled temperature of 30 °C using disposable 8 mm vials. Samples were measured on the XDS RapidLiquid Analyzer. Data acquisition and model development were conducted with Vision Air Complete software. Key instrument components:
  • XDS RapidLiquid Analyzer (Metrohm 2.921.1410)
  • Disposable glass vials, 8 mm path length (Metrohm 6.7402.000)
  • Vision Air 2.0 Complete software (Metrohm 6.6072.208)

Main Results and Discussion


The Vis-NIR models demonstrated strong correlation with reference methods:
  • Cetane index: R2=0.991, SEC=0.093, SECV=0.143.
  • Flash point: R2=0.977, SEC=2.22 °C, SECV=2.50 °C.
  • CFPP: R2=0.973, SEC=1.99 °C, SECV=2.24 °C.
  • D95 (distillation endpoint): R2=0.861, SEC=3.07 °C, SECV=3.47 °C.
  • Viscosity at 40 °C: R2=0.983, SEC=0.038 cSt, SECV=0.047 cSt.

Overall, Vis-NIR enables reliable multi-parameter screening in under one minute without sample preparation.

Benefits and Practical Applications


  • Rapid analysis: complete parameter set in under 1 minute.
  • No chemical reagents or sample preparation required.
  • Simultaneous determination reduces laboratory workload and instrument costs.
  • Suitable for routine quality control in laboratories and production environments.

Future Trends and Potential Applications


  • Integration into inline and at-line process control systems for real-time monitoring.
  • Expansion of calibrations to cover diverse diesel grades and biofuel blends.
  • Application of machine learning algorithms to enhance prediction robustness.
  • Development of portable Vis-NIR devices for field testing and on-site quality assurance.

Conclusion


Vis-NIR spectroscopy with the XDS RapidLiquid Analyzer offers a fast, accurate, and reagent-free alternative to traditional diesel quality assays. The method streamlines multi-parameter testing, maintaining comparable precision to reference standards and supporting efficient quality control workflows.

Reference


  • Metrohm AG. AN-NIR-080: Quality Control of Diesel. Application Note.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Quality Control of Lubricants
Quality Control of Lubricants
2020|Metrohm|Applications
AN-NIR-041 Quality Control of Lubricants Fast and chemical-free determination of the acid number, viscosity, moisture content, and color number of lubricants with NIRS Summary For lubricant analysis, determination of the Acid Number (ASTM D664), viscosity (ASTM D445), moisture content (ASTM…
Key words
metrohm, metrohmxds, xdserror, errorrapidliquid, rapidliquidmerit, meritfigures, figuresanalyzer, analyzernirs, nirscross, crossstandard, standardsimple, simpleresult, resultvalidation, validationnumber, numberlubricants
Quality Control of Palm Oil
Quality Control of Palm Oil
2020|Metrohm|Applications
AN-NIR-044 Quality Control of Palm Oil Environmentally friendly determination of FFA content, iodine value, moisture, DOBI, and carotene content Summary Determination of key quality parameters of palm oil, namely free fatty acids (FFA), iodine value (IV), moisture content, deterioration of…
Key words
metrohm, metrohmerror, errorxds, xdsmerit, meritfigures, figuresrapidliquid, rapidliquidcarotene, carotenecross, crossstandard, standardpalm, palmvalidation, validationvalue, valuenir, niranalyzer, analyzersimple
Quality Control of Gasoline
Quality Control of Gasoline
2020|Metrohm|Applications
AN-NIR-022 Quality Control of Gasoline Rapid determination of RON, MON, AKI, aromatic content, and density Summary In recent years, there has been a significant push to reduce the environmental impacts of fuels through improvements to fuel quality. This requires engines…
Key words
metrohm, metrohmerror, errormerit, meritxds, xdsfigures, figuresrapidliquid, rapidliquidcfr, cfrvalue, valuecross, crossstandard, standardaki, akiresult, resultvalidation, validationengine, engineanalyzer
Quality Control of Palm Oil
Quality Control of Palm Oil
2020|Metrohm|Applications
AN-NIR-085 Quality Control of Palm Oil Accurate and precise determination of the iodine value Summary Determination of key quality parameters of palm oil, such as the iodine value (IV), are typically performed using time consuming and costly wet chemical methods.…
Key words
metrohm, metrohmxds, xdsnirs, nirserror, erroranalyzer, analyzersimple, simplerapidliquid, rapidliquidmerit, meritfigures, figuresvial, vialheater, heaterthus, thusvialheater, vialheateraccurate, accuratevalue
Other projects
GCMS
LCMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike