Determination of Lead in Unleaded Gasoline by ICP–OES with the Use of Oxygen and a Cooled Spray Chamber
Applications
| 2010 | Agilent Technologies
ICP/OES
Instrumentation
ICP/OES
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals
Screening for Sensitive Explosives with Agilent Resolve - a Handheld SORS System
Applications
| 2018 | Agilent Technologies
RAMAN Spectroscopy
Instrumentation
RAMAN Spectroscopy
Manufacturer
Agilent Technologies
Industries
Homeland Security
Agilent Inorganic Certified Reference Materials and Standards
Brochures and specifications
| 2021 | Agilent Technologies
Consumables
Instrumentation
Consumables
Manufacturer
Agilent Technologies
Industries
Trace Metal Analysis of Waters using the Carbon Rod Atomizer — a Review
Applications
| 2010 | Agilent Technologies
AAS
Instrumentation
AAS
Manufacturer
Agilent Technologies
Industries
Environmental
Methods for Environmental Samples
Applications
| 2010 | Agilent Technologies
AAS
Instrumentation
AAS
Manufacturer
Agilent Technologies
Industries
Environmental
ANALYSIS OF EXTRACTABLE AND LEACHABLE METALS IN PLASTIC MATERIALS OF CONSTRUCTION AS PER USP <661.1> ACID EXTRACTION PROCEDURE USING THE AGILENT 5110 VDV ICP-OES
Applications
| 2016 | Agilent Technologies
LC/Orbitrap, ICP/OES
Instrumentation
LC/Orbitrap, ICP/OES
Manufacturer
Agilent Technologies
Industries
Materials Testing
Accurate Quantification of Cadmium, Chromium, Mercury and Lead in Plastics for RoHS Compliance using the Agilent 7500ce ICP-MS
Applications
| 2009 | Agilent Technologies
ICP/MS
Instrumentation
ICP/MS
Manufacturer
Agilent Technologies
Industries
Materials Testing
Sensitive, high-throughput analysis of lead in whole blood using the Agilent 7500cx ICP-MS with ISIS-DS
Applications
| 2015 | Agilent Technologies
ICP/MS
Instrumentation
ICP/MS
Manufacturer
Agilent Technologies
Industries
Clinical Research
Direct Determination of As, Cu and Pb in Seawater by Zeeman Graphite Furnace Atomic Absorption Spectrometry
Applications
| 2010 | Agilent Technologies
AAS
Instrumentation
AAS
Manufacturer
Agilent Technologies
Industries
Environmental
Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode
Environmental chemist Branislav Vrana: To the first conference, we drove in an old Skoda Felicia
Tu, 4.6.2024
RECETOX - Centrum pro výzkum toxických látek v prostředí
The world around us is changing and we have to react
Mo, 3.6.2024
Vysoká škola chemicko-technologická v Praze
"The first science communicators for me were already high school teachers,” says researcher and laureate of the Learned Society of the Czech Republic award, Barbora Rudzanová.
Su, 2.6.2024
RECETOX - Centrum pro výzkum toxických látek v prostředí