Similar PDF

Toggle
Agilent 8900 Triple Quadrupole ICP-MS brochure
2020|Agilent Technologies|Brochures and specifications
Leave InterferencesBehind With MS/MS.Agilent 8900 Triple Quadrupole ICP-MS Put Your ICP-MS Results Beyond DoubtReliable interference removal is easierto achieve with the 2nd generationAgilent 8900 ICP-QQQ.In 2012, Agilent released the Agilent 8800, the world’sfirst triple quadrupole ICP-MS (ICP-QQQ) with MS/MScapability. This ground-breaking...
Key words
icp, icpqqq, qqqnanoparticle, nanoparticlecps, cpsions, ionsmasshunter, masshuntercell, cellparticle, particlesingle, singleagilent, agilentanalysis, analysisintegrated, integratedreaction, reactioninterferences, interferencessemiconductor
Agilent 8900 Triple Quadrupole ICP-MS
2016|Agilent Technologies|Technical notes
Agilent 8900 Triple Quadrupole ICP-MSTechnical OverviewIntroductionAgilent is the worldwide market leader in quadrupole ICP-MS, and the onlysupplier of triple quadrupole ICP-MS (ICP-QQQ).Introduced in 2012, ICP‑QQQ has transformed interference removal inICP‑MS, using MS/MS to control reaction chemistry and deliver consistent,reliable results...
Key words
icp, icpqqq, qqqsensitivity, sensitivityacceleration, accelerationions, ionsdls, dlscell, cellreaction, reactionsemiconductor, semiconductorquadrupole, quadrupoleapplications, applicationssignal, signalaxial, axialhigh, highnps
Agilent ICP-MS Journal (July 2016 – Issue 66)
2016|Agilent Technologies|Others
Agilent ICP-MS JournalJuly 2016 – Issue 66Inside this Issue2-3The New Agilent 8900 ICP-QQQ Provides Improved Performance and Enhanced Flexibility4Building on the Success of the Innovative Agilent8800 ICP-QQQ5Characterization of Nanoparticle Content usingSingle Particle ICP-QQQ6-7The Advantages of Agilent ICP-QQQ for Nuclear Applications8Recorded...
Key words
icp, icpqqq, qqqnuclear, nuclearagilent, agilentapplications, applicationsnanoparticle, nanoparticleinterferences, interferencesperformance, performancesensitivity, sensitivityuranium, uraniumsemiconductor, semiconductorawards, awardsnps, npstrace, traceparticle
Agilent ICP-MS JournalOctober 2017 – Issue 70Inside this Issue2-3The Benefits of MS/MS for Reactive Cell GasMethods in ICP-MS4-5ASTM Issue ICP-MS Method for Analysis ofPetroleum Distillate Products5Educational Spotlight: The Role of ICP-MS inInvestigating Neurodegenerative Diseases6-7Fast Analysis of Arsenic Species in Winesusing...
Key words
icp, icpions, ionselements, elementsbandpass, bandpassspecies, speciesoverlaps, overlapsquadrupole, quadrupolecell, cellagilent, agilentarsenic, arsenicyes, yesias, iasmass, massproduct, productdistillate