Determination of chromium(VI) in toy migration solution applying IC-ICP/MS
Aplikace | | MetrohmInstrumentation
IC-MS, ICP/MS, Speciační analýza
IndustriesMateriálová analýza
ManufacturerAgilent Technologies, Metrohm
Key wordsmigration, icp, toy, carbonate, solution, crayon, hydrogen, chromate, mipt, bank, neutralization, carcinogenic, pmax, chromium, preconcentration, parameters, reason, recording, corrected, inline, remote, quad, box, applying, potentially, toxic, intelligent, metrohm, considered, buffer, flow, integration, injected, eluent, time, instrumentation, technique, transfer, sample, solutions, columns, single, determination, calibration, mode, volume, rate, which, injection, detection
Similar PDF
Coupling of ion chromatography and inductively-coupled plasma mass spectrometry
2017|Agilent Technologies|Guides
Metrohm White Paper Coupling of ion chromatography and inductively-coupled plasma mass spectrometry By Katinka Ruth and Markus Läubli Online hyphenation of ion chromatography (IC) to inductively coupled plasma mass spectrometry (ICP/ MS) is a powerful instrumental tool to handle some…
Key words
metrohm, metrohmpaper, paperwhite, whiteicp, icparsenic, arsenicspecies, speciesspeciated, speciatedmercury, mercuryspeciation, speciationchromium, chromiumselenium, seleniumisotope, isotopeinductively, inductivelybromate, bromatethallium
The Migration of Elements from Toys and Speciation of Chromium (VI) in Toy Material Using a Low Cost IC-ICP-MS Solution
2016|Thermo Fisher Scientific|Aplikace
Daniel Kutscher, Shona McSheehy Ducos, Lothar Rottmann, Thermo Fisher Scientific, Germany Appli cat i on N ote 4 3 1 7 5 The Migration of Elements from Toys and Speciation of Chromium (VI) in Toy Material Using a Low Cost…
Key words
toy, toychromium, chromiumicp, icpelemental, elementalspeciation, speciationicap, icapmigration, migrationpaint, paintpfa, pfafinger, fingertotal, totalscientific, scientificspiked, spikedquantification, quantificationqcell
Determination of chromate in water applying IC-ICP/MS detection
|Agilent Technologies|Aplikace
IC Application Note M–8 Determination of chromate in water applying IC-ICP/MS detection Hexavalent chromium (chromate) is considered toxic and potentially carcinogenic for which reason its concentration in environmental and drinking water should be as low as possible. The determination of…
Key words
icp, icpchromate, chromategacp, gacpwater, waterasx, asxspray, spraycetac, cetactorque, torquehexavalent, hexavalentsea, seacarcinogenic, carcinogenicpmax, pmaxregenerant, regenerantchromium, chromiumsolutions
Speciation Applications Summary Ion Chromatography
2017|Thermo Fisher Scientific|Guides
Speciation Applications Summary Ion Chromatography Elemental Species Separation and Detection Table of contents Introduction Speciation Analysis 3 Complete inorganic analysis Periodic Table of Total Inorganic Analysis 4 Arsenic IC-ICP-MS speciation analysis of As in apple juice using the Thermo Scientific…
Key words
icp, icpicap, icapspeciation, speciationarsenic, arsenicmercury, mercurylod, lodinorganic, inorganiciodide, iodiderice, ricespecies, speciescoupled, coupledversion, versionequivalent, equivalentinductively, inductivelydownload